Brother International BAS-342G Instruction Manual - English - Page 75

Table Of Error Codes, Danger

Page 75 highlights

12. TABLE OF ERROR CODES 12. TABLE OF ERROR CODES DANGER Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet before opening the cover of the control box. Touching areas where high voltages are present can result in severe injury. If a malfunction should occur with the sewing machine, a buzzer will sound and an error code will appear in the display window. Follow the remedy procedure to eliminate the cause of the problem. Switch-related errors Code Cause and remedy E010 Stop switch was pressed. Press the RESET key to clear the error. E011 Stop switch was pressed. Press the RESET key to clear the error. Press the key to move the work clamp so that you can continue sewing. E015 The stop switch was still being pressed, or there is a problem with the stop switch connection. Turn off the power, and then check that connector P13 on the main P.C. board is properly connected. E016 Problem with the stop switch connection. Turn off the power, and then check that connector P13 on the main P.C. board is properly connected. The power was turned on while the start switch was still being depressed, or the start switch was depressed without the work clamp being lowered. E025 If the power has been turned on while the start switch was still depressed, turn off the power and check the start switch. If the start switch was depressed without lowering the work clamp, depress the work clamp switch to lower the work clamp. E035 The work clamp switch is depressed. Turn off the power, and then check the work clamp switch. E036 A foot switch that does not match specifications is connected, or work clamp mode has not been set correctly. Use a foot switch that matches specifications, or initialize the memory switch settings. Machine head tilting was detected after the power was turned on. E050 Turn off the power, and then return the machine head to its original position. Check that connector P9 on the main P.C. board is properly connected. E051 Machine head tilting was detected while the sewing machine was operating. Turn off the power, and then check that connector P9 on the main P.C. board is properly connected. Machine head tilting was detected when the power was turned on. E055 Turn off the power, and then return the machine head to its original position. Check that connector P9 on the main P.C. board is properly connected. E065 An operation panel key was still being pressed when the power was turned on, or key is faulty. Turn off the power and check the operation panel. Upper shaft motor-related errors Code Cause and remedy E110 Needle up stop position error. Turn the machine pulley until the point where the error display disappears. E111 Upper shaft did not stop at the needle up stop position when the sewing machine stopped. Turn the machine pulley until the point where the error display disappears. E120 Needle drop signal could not be detected. Turn off the power, and then check the synchronizer connection. E121 Thread trimming was not completed. Turn off the power, and then check if the cutting edges of the fixed knife and movable knife are damaged or worn. (Continued on next page) BAS-342G 66

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

12. TABLE OF ERROR CODES
BAS-342G
66
12. TABLE OF ERROR CODES
DANGER
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet
before opening the cover of the control box. Touching areas where high voltages are present can result in severe
injury.
If a malfunction should occur with the sewing machine, a buzzer will sound and an error code will appear in the display
window. Follow the remedy procedure to eliminate the cause of the problem.
Switch-related errors
Code
Cause and remedy
E010
Stop switch was pressed. Press the RESET key to clear the error.
E011
Stop switch was pressed. Press the RESET key to clear the error.
Press the
key to move the work clamp so that you can continue sewing.
E015
The stop switch was still being pressed, or there is a problem with the stop switch connection.
Turn off the power, and then check that connector P13 on the main P.C. board is properly connected.
E016
Problem with the stop switch connection.
Turn off the power, and then check that connector P13 on the main P.C. board is properly connected.
E025
The power was turned on while the start switch was still being depressed, or the start switch was depressed
without the work clamp being lowered.
If the power has been turned on while the start switch was still depressed, turn off the power and check the start
switch.
If the start switch was depressed without lowering the work clamp, depress the work clamp switch to lower the
work clamp.
E035
The work clamp switch is depressed.
Turn off the power, and then check the work clamp switch.
E036
A foot switch that does not match specifications is connected, or work clamp mode has not been set correctly.
Use a foot switch that matches specifications, or initialize the memory switch settings.
E050
Machine head tilting was detected after the power was turned on.
Turn off the power, and then return the machine head to its original position.
Check that connector P9 on the main P.C. board is properly connected.
E051
Machine head tilting was detected while the sewing machine was operating.
Turn off the power, and then check that connector P9 on the main P.C. board is properly connected.
E055
Machine head tilting was detected when the power was turned on.
Turn off the power, and then return the machine head to its original position.
Check that connector P9 on the main P.C. board is properly connected.
E065
An operation panel key was still being pressed when the power was turned on, or key is faulty.
Turn off the power and check the operation panel.
Upper shaft motor-related errors
Code
Cause and remedy
E110
Needle up stop position error.
Turn the machine pulley until the point where the error display disappears.
E111
Upper shaft did not stop at the needle up stop position when the sewing machine stopped.
Turn the machine pulley until the point where the error display disappears.
E120
Needle drop signal could not be detected.
Turn off the power, and then check the synchronizer connection.
E121
Thread trimming was not completed.
Turn off the power, and then check if the cutting edges of the fixed knife and movable knife are damaged or worn.