Brother International BAS-375E Programmer Instruction Manual - English - Page 160
Canceling thread breakage at the last stitch, Programming, Inputting the end code
View all Brother International BAS-375E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 160 highlights
Chaprter 3 Programming with Command Function Canceling thread breakage at the last stitch Stitch length Addition of feed after the last point can cancel thread breakage at the last stitch. When "115" is input for the end code, the thread breakage does not occur. In this case, every thread breakage including emergency stop is canceled. Carry out the following setting for canceling thread breakage at the specified point. Programming 1. Create the program 1 stitch (A) before the desired end point. 2. Press 9 9 9 and press F . 3. Move the work clamp with for the stitch length. Press L when the needle point is at point B of the pattern. Point B is programmed. 4. Press F . 5. Move the work clamp with . Press L when the needle point is at given point C. Inputting the end code 1. Press L and press 1 1 1 E . Programmer 159