Brother International BES-1210AC Cap to Tubular - English - Page 1
Brother International BES-1210AC Manual
View all Brother International BES-1210AC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
BAS-416, BAS-416A & BES & 1210 For Technical Assistance Please Call Toll Free 1-877-4BROTHER With the power to the machine in the ON position. 1) Remove the two screws (K) and loosen screw (J), it may be a thumbscrew or Phillips screw. Swing the L shape bracket (H) down. NOTE: Do not attach these two screws (K) when not using cap drive system 2) Loosen the black thumb screw (G) and slide the guide bar (F) out of the lower arm. 3) Remove the two short black thumb screws, inner ones, (E) and remove the cap driver from the machine by sliding it toward you. 4) Remove the two long black thumb screws (D) and remove the metal bar with the "L" stamped into the top left corner of the plate from guide pins (C). 5) Remove the cap needle plate (A-2) and replace with the flat needle plate (A-1). 6) Turn machine off and move the switch (L) to "FLAT" mode and turn the power back on. 7) Move the needle case to needle #1 using the needle select button. 8) Turn the pulley in the direction of the arrow to 200 degrees. 9) Loosen the screw that secures the presser foot (B) and adjust presser foot height to the thickness of a dime and then re-tighten screw. 10) Turn the pulley back to 100 degrees and raise presser foot with lever. 11) Place the TUBULAR arm attachment (A) onto the machine over the positioning pins (C). 12) Attach using the longer Philips screws that have both a flat and spring washer. Remove this screw on each side