Brother International BES-1216AC Instruction Manual - English - Page 144

main PCB CPU, Error Messages

Page 144 highlights

Chapter 9 Error code list Code Error Messages E-E3 Exhaust fan motor stop E-E5 ERROR E5 E-E6 ERROR E6 E-E7 ERROR E7 E-E8 ERROR E8 E-E9 ERROR E9 E-EA ERROR EA E-EB ERROR EB E-EC ERROR EC E-ED ERROR ED E-EF ERROR EF E-F1 ERROR F1 E-F2 ERROR F2 E-F3 ERROR F3 E-F4 ERROR F4 E-F5 ERROR F5 E-F6 ERROR F6 E-F7 ERROR F7 E-F8 ERROR F8 E-F9 ERROR F9 E-FA ERROR FA E-FB ERROR FB E-FF ERROR FF Error Measures Cooling fan motor stop. Over-run error during interfacing to main PCB CPU Framing error during interfacing to main PCB CPU Turn off the power and check the fan harness. Turn on the power again. If the same error occurs again, the fan or the main PCB is faulty. Parity error during interfacing to main PCB CPU Receiving time up error during interfacing to main PCB CPU Send/Receive inconsistent error during interfacing to main PCB CPU ACK code receiving error during interfacing to main PCB CPU Send/Receive ID code error during interfacing to main PCB CPU Send data checksum error during interfacing to main PCB CPU Data empty error during interfacing to main PCB CPU Receiving error on interface Send time up error Request-to-waiting time up error This is not usually displayed. Request-to-recive time up error Receive command error NACK code receiving error Data requested for needle position can not be returned. It is not receive command for the request one. PRE code error No applicable command Interface receive data sum check error Send time up error No status is returned from main shaft CPU. 142 BES-916AC • BES-1216AC

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157

Chapter 9
Error code list
BES-916AC • BES-1216AC
142
Code
Error Messages
Error
Measures
E-E3
E-E5
E-E6
E-E7
E-E8
E-E9
E-EA
E-EB
E-EC
E-ED
E-EF
E-F1
E-F2
E-F3
E-F4
E-F5
E-F6
E-F7
E-F8
E-F9
E-FA
E-FB
E-FF
Exhaust fan motor stop
ERROR E5
ERROR E6
ERROR E7
ERROR E8
ERROR E9
ERROR EA
ERROR EB
ERROR EC
ERROR ED
ERROR EF
ERROR F1
ERROR F2
ERROR F3
ERROR F4
ERROR F5
ERROR F6
ERROR F7
ERROR F8
ERROR F9
ERROR FA
ERROR FB
ERROR FF
Cooling fan motor stop.
Over-run error during interfacing to main
PCB
CPU
Framing error during interfacing to main PCB
CPU
Parity error during interfacing to main PCB CPU
Receiving time up error during interfacing to
main PCB CPU
Send/Receive inconsistent error during interfac-
ing to main PCB CPU
ACK code receiving error during interfacing to
main PCB CPU
Send/Receive ID code error during interfacing to
main PCB CPU
Send data checksum error during interfacing to
main PCB CPU
Data empty error during interfacing to main PCB
CPU
Receiving error on interface
Send time up error
Request-to-waiting time up error
Request-to-recive time up error
Receive command error
NACK code receiving error
Data requested for needle position can not be
returned.
It is not receive command for the request one.
PRE code error
No applicable command
Interface receive data sum check error
Send time up error
No status is returned from main shaft CPU.
Turn off the power and check the fan harness.
Turn on the
power again.
If the same error occurs again, the fan or the
main PCB is faulty.
This is not usually displayed.