[ Disassembling the Control Panel ASSY ] 1) Turn the control panel ASSY upside down. 2) Remove two screws "a." 3) Slightly lift up the control panel PCB, then unlock the FPC key connector and disconnect the FPC key. Next, unlock the LCD cable connector and disconnect the LCD flat cable. 4) Remove six screws "b." 5) Remove the key support plate and FPC key. "a": Taptite, cup B M2.6x8 "b": Taptite, cup B M3x6 6) As shown below, slightly pull the clamp outwards and take out the LCD while pulling the LCD flat cable gently. NOTE: Do not take out the LCD except when the LCD is defective and requires replacement. n Reassembling Notes • Before reinstalling the LCD to the control panel, wipe fingerprints or dust off the LCD surface and control panel window with a soft cloth. • A new LCD is covered with a protection sheet. Before installing it, remove the protection sheet. IV - 24