Brother International KE-435C Instruction Manual - English - Page 28

Operating procedure, OPERATION, 2-1. Setting the program number

Page 28 highlights

5. OPERATION 5-2. Operating procedure Preparation Turn on the power switch. * The POWER indicator (1) will illuminate and the program number will flash in the display window (14). Program No. X-scale (%) Y-scale (%) Speed (rpm) Factory default 0*1 100 100 2,000 Variable range 100- *2 20 - 200 20 - 200 1,000 - 2,500 *1 For checking the origin points for X and Y feed *2 Custom-made program Note when creating additional data When sewing data with a small number of stitches (15 stitches or less) is sewn repeatedly (short cycle operation), the upper shaft motor may overheat and the "E-20" error code may be generated. 5-2-1. Setting the program number Press the SELECT switch (6) 1 until the PROGRAM NO. indicator illuminates. Press the DISPLAY SET 2 switches (12) until the desired program number is flashing in the display window. Depress the foot switch to the 3 second step. Note: For two-pedal foot switch, depress the work clamp switch to lower the work clamp, before depressing the start switch. * The display will stop flashing and illuminates steadily, and the feed mechanism will move to the sewing start position. 1st step 2nd step 0085Q 2516Q 2602Q 5-2-2. Setting the X-scale and Y-scale Press the SELECT switch (6) 1 until the X-scale or Y-scale indicator illuminates. 2 Press the DISPLAY SET switches (12) until the desired scale setting is flashing in the display window. (The setting is displayed as a per- centage.) This completes the setting of the program number. Depress the foot switch to the 3 second step. Note: For two-pedal foot switch, depress the work clamp switch to lower the work clamp, before depressing the start switch. * The display will stop flashing and illuminates steadily, and the feed mechanism will move to the sewing start position. 0085Q 1st step 2nd step 2518Q 2519Q This completes the setting of the X-scale or Yscale. Note: * Be sure to check the sewing pattern (refer to page 26) after setting has been completed to make sure that the needle hole does not go out of the area circumscribed by the work clamp. * The needle racking width for backtack stitches (with stitch widths of 1 mm or less) is not enlarged or reduced. If this results in problems, set memo-0d to "ON". 22 KE-434C,435C

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83

5. OPERATION
22
KE-434C,435C
5-2. Operating procedure
Preparation
Turn on the power switch.
* The POWER indicator (1) will illuminate and the
program number will flash in the display window (14).
*1 For checking the origin points for X and Y feed
*2 Custom-made program
Note when creating additional data
When sewing data with a small number of stitches (15 stitches or less) is sewn repeatedly (short cycle operation), the
upper shaft motor may overheat and the β€œE-20” error code may be generated.
5-2-1. Setting the program number
1
Press the SELECT switch (6)
until the PROGRAM NO. in-
dicator illuminates.
2
Press
the
DISPLAY
SET
switches (12) until the desired
program number is flashing in
the display window.
3
Depress the foot switch to the
second step.
Note:
For
two-pedal
foot
switch,
depress the work clamp switch
to lower
the
work
clamp,
before depressing the start
switch.
* The display will stop flashing and
illuminates
steadily,
and
the
feed
mechanism will move to the sewing
start position.
This completes the setting of the program
number.
5-2-2. Setting the X-scale and Y-scale
3
Depress the foot switch to the
second step.
Note:
For
two-pedal
foot
switch,
depress the work clamp switch
to lower
the
work
clamp,
before depressing the start
switch.
1
Press the SELECT switch (6)
until the X-scale or Y-scale
indicator illuminates.
2
Press
the
DISPLAY
SET
switches (12) until the desired
scale setting is flashing in the
display window.
(The setting is displayed as a per-
centage.)
* The display will stop flashing and
illuminates
steadily,
and
the
feed
mechanism will move to the sewing
start position.
This completes the setting of the X-scale or Y-
scale.
Note:
*
Be sure to check the sewing pattern (refer to page 26) after setting has been completed to make sure that the needle hole
does not go out of the area circumscribed by the work clamp.
*
The needle racking width for backtack stitches (with stitch widths of 1 mm or less) is not enlarged or reduced. If this results
in problems, set memo-0d to β€œON”.
2518Q
2519Q
0085Q
1st step
2nd step
1st step
2nd step
0085Q
2516Q
2602Q
Factory default
Variable range
Program No.
0
*
1
100-
*
2
X-scale (%)
100
20 - 200
Y-scale (%)
100
20 - 200
Speed (rpm)
2,000