Brother International PJ-883 Raster Command Reference - Page 24

B H + 7E H + 64 H + {n1} + 00 H

Page 24 highlights

Brother PJ-600/700/800 Series Command Reference 21 Name Bidirectional transmission mode Syntax ESC + ~ + e + D + {n1} 1B H + 7E H + 65 H + 44 H + {n1} Description When bidirectional transmission is enabled, the printer returns the "printing completed" status when printing is finished. In addition, if an error occurred during printing, all print data received for those pages is discarded. Definition of {n1}: 0: Disable (default) 1: Enable *Replies with a "status information request" command even if bidirectional transmission is disabled. Name Set density Syntax ESC + ~ + d + {n1} + null 1B H + 7E H + 64 H + {n1} + 00 H Description Specifies the print density. Note: Print density may differ from the conditions, such as the type of thermal paper, print pattern, environment, etc. Please set the appropriate density. Definition of {n1}: 0 to 255 The lower the parameter value, the lower the density becomes. Parameter n1 0 (00 H) ~ 23 (17 H) Density amount 0 24 (18 H) ~ 47 (2F H) 1 48 (30 H) ~ 71 (47 H) 2 72 (48 H) ~ 95 (5F H) 3 96 (60 H) ~ 119 (77 H) 4 120 (78 H) ~ 143 (8F H) 5 144 (90 H) ~ 167 (A7 H) 6 168 (A8 H) ~ 191 (BF H) 7 192 (C0 H) ~ 215 (D7 H) 8 216 (D8 H) ~ 239 (EF H) 9 240 (F0 H) ~ 255 (FF H) 10 © 2015 Brother Industries, Ltd. All Rights Reserved.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

Brother PJ-600/700/800 Series Command Reference 21
© 2015 Brother Industries, Ltd. All Rights Reserved.
Name
Bidirectional transmission mode
Syntax
ESC +
~
+ e + D + {n1}
1B H + 7E H + 65 H + 44 H + {n1}
Description
When bidirectional
transmission is enabled, the printer returns the “printing completed”
status when printing is finished. In addition, if an error occurred during printing, all print
data received for those pages is discarded.
Definition of {n1}:
0
Disable (default)
1
Enable
*Replies with a “status information request” command even if
bidirectional transmission
is disabled.
Name
Set density
Syntax
ESC +
~
+ d + {n1} + null
1B H + 7E H + 64 H + {n1} + 00 H
Description
Specifies the print density.
Note: Print density may differ from the conditions, such as the type of thermal paper,
print pattern, environment, etc. Please set the appropriate density.
Definition of {n1}: 0 to 255
The lower the parameter value, the lower the density becomes.
Parameter n1
Density amount
0
(00 H)
23
(17 H)
0
24
(18 H)
47
(2F H)
1
48
(30 H)
71
(47 H)
2
72
(48 H)
95
(5F H)
3
96
(60 H)
119 (77 H)
4
120 (78 H)
143 (8F H)
5
144 (90 H)
167 (A7 H)
6
168 (A8 H)
191 (BF H)
7
192 (C0 H)
215 (D7 H)
8
216 (D8 H)
239 (EF H)
9
240 (F0 H)
255 (FF H)
10