Brother International QL-820NWB P-touch Template Manual/ Command Reference - Page 27

D barcodes, The Code Spacing and Join Vertically in the Set Structured Append settings

Page 27 highlights

P-touch Template Command Reference 4.2.3 2D barcodes QR Code PDF417 Data Matrix Maxi Code Aztec The version setting for a QR Code specified in P-touch Editor is invalid. The version setting must be turned off. The Structured Append settings specified in P-touch Editor are invalid. If the value specified with the QR Code version command is outside of the allowable range, it is changed to AUTO. (MODEL1:0 to 14, MODEL2:0 to 40, MicroQR:0 to 4) Since the error correction levels for PDF417 specified in P-touch Editor are inconsistent with those on the printer, the size of the barcode may change when it is printed with P-touch Template. The width for PDF417 specified in P-touch Editor may change from the medium size to the small size. The Structured Append settings specified in P-touch Editor are invalid. The Structured Append settings specified in P-touch Editor are invalid. Macro settings specified in P-touch Editor are invalid. The Structured Append settings specified in P-touch Editor are invalid. The barcode is partitioned when too much data is entered. When specifying the country code and service class with P-touch Editor, the number is entered at the beginning if the maximum number of characters is not reached. However, with the printer, the number is entered at the end. Example: "2" is specified. P-touch Editor: "200"; Printer: "002" The Remove Character setting specified in P-touch Editor is invalid. When the Number of Parts in the Set Structured Append setting is specified as Auto, the number of appended blocks becomes 2. The Code Spacing and Join Vertically in the Set Structured Append settings specified in P-touch Editor are invalid. - 22 - 4. P-touch Template Limitations

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101

P-touch Template Command Reference
- 22 -
4. P-touch Template Limitations
4.2.3 2D barcodes
QR Code
The version setting for a QR Code specified in P-touch Editor is invalid. The
version setting must be turned off.
The Structured Append settings specified in P-touch Editor are invalid.
If the value specified with the QR Code version command is outside of the
allowable range, it is changed to AUTO. (MODEL1:0 to 14, MODEL2:0 to 40,
MicroQR:0 to 4)
PDF417
Since the error correction levels for PDF417 specified in P-touch Editor are
inconsistent with those on the printer, the size of the barcode may change when
it is printed with P-touch Template.
The width for PDF417 specified in P-touch Editor may change from the medium
size to the small size.
The Structured Append settings specified in P-touch Editor are invalid.
Data Matrix
The Structured Append settings specified in P-touch Editor are invalid.
Macro settings specified in P-touch Editor are invalid.
Maxi Code
The Structured Append settings specified in P-touch Editor are invalid.
The barcode is partitioned when too much data is entered.
When specifying the country code and service class with P-touch Editor, the
number is entered at the beginning if the maximum number of characters is not
reached. However, with the printer, the number is entered at the end.
Example: “2” is specified.
P-touch Editor: “200”; Printer: “002”
Aztec
The Remove Character setting specified in P-touch Editor is invalid.
When the Number of Parts in the Set Structured Append setting is specified as
Auto, the number of appended blocks becomes 2.
The Code Spacing and Join Vertically in the Set Structured Append settings
specified in P-touch Editor are invalid.