Brother International TD-2020 Raster Command Reference - Page 30
Notification number, Notification, Value, Battery level, Finished waiting for peeling
View all Brother International TD-2020 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
(7) Notification number Notification Not available Cooling (started) Cooling (finished) Waiting for peeling Finished waiting for peeling (Not used:Reserved) Printer paused Finished printer pause (Not used:Reserved) (8) Battery level Battery Level Full Half Low Charging required AC adaptor in use Raster Command Reference Value 00h 03h 04h 05h 06h 07h 08h Value 00h 01h 02h 03h 04h - 26 - 4. Printing Command Details
Raster Command Reference
- 26 -
4. Printing Command Details
(7) Notification number
Notification
Value
Not available
00h
Cooling (started)
03h
Cooling (finished)
04h
Waiting for peeling
05h
Finished waiting for peeling
(
Not used
:
Reserved
)
06h
Printer paused
07h
Finished printer pause
(
Not used
:
Reserved
)
08h
(8) Battery level
Battery Level
Value
Full
00h
Half
01h
Low
02h
Charging required
03h
AC adaptor in use
04h