Brother International TD-2135NWB ESC/ P Command Reference - Page 87
ESC i P QR Code version, End of barcode
View all Brother International TD-2135NWB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 87 highlights
(3) \\\: End of barcode There must be three backslashes to end 2D barcode. Example Refer to the section "Summary". ESC/P Command Reference ESC i P QR Code version ASCII: ESC i P n Hexadecimal: 1B 69 50 n Parameters 0≤n≤40 Description The barcode size can be fixed. The default value is 0 (auto). The available versions differ depending on the symbol type used. If a setting other than those listed is specified, the setting returns to its default. The following settings are available for each symbol type. Model1 (0-14), Model2 (0-40), MicroQR (0-4) - 81 - 5. Control Command Details
ESC/P Command Reference
- 81 -
5. Control Command Details
(3)
\\\:
End of barcode
There must be three backslashes to end 2D barcode.
Example
Refer to the section “
Summary
”.
ESC i P
QR Code version
ASCII:
ESC
i
P
n
Hexadecimal: 1B
69
50
n
Parameters
0
≤
n
≤
40
Description
The barcode size can be fixed.
The default value is 0 (auto).
The available versions differ depending on the symbol type used.
If a setting other than those listed is specified, the setting returns to its default.
The following settings are available for each symbol type.
Model1 (0–14), Model2 (0–40), MicroQR (0–4)