ESC iX31 Retrieve default line feed, ESC iXA2 Select default alignment
View all Brother International TD-4410D manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 116 highlights
ESC iX31 Retrieve default line feed ASCII: ESC i X Decimal: 27 105 88 Hexadecimal: 1B 69 58 3 1 51 49 33 31 n1 n2 n1 n2 n1 n2 Parameters n1: 00h (Fixed) n2: 00h (Fixed) Description The default line feed setting is returned as 4-byte data. [1] 02h (Fixed) [2] 00h (Fixed) [3, 4] n3 n4 settings n3+(n4*256): Default line feed (dots) The retrieved value is a value specified by a static command. ESC iXA2 Select default alignment ASCII: ESC i X Decimal: 27 105 88 Hexadecimal: 1B 69 58 A 2 65 50 41 32 n1 n2 n3 n1 n2 n3 n1 n2 n3 Parameters n1: 01h (Fixed) n2: 00h (Fixed) 00h≤n3≤02h Description Selects the default alignment. n3=00h: Left alignment (*Manufacturer's default) n3=01h: Center alignment n3=02h: Right alignment This command is a static command. Remarks Invalid if n3 is a value outside of the allowable range ESC/P Command Reference - 110 - 5. Control Command Details