CS300 Pyranometer 4. Wiring A schematic diagram of the CS300 is shown in Figure 4-1. Single-Ended RED Analog Input BLACK Ground/AG 500 to 600 Ω typical CLEAR Ground/G FIGURE 4-1. CS300 Schematic Connections to Campbell Scientific dataloggers are given in Table 4-1. When Short Cut for Windows software is used to create the datalogger program, the sensor should be wired to the channels shown in the wiring diagram created by Short Cut. TABLE 4-1. Connections to Campbell Scientific Dataloggers Color Red Black Clear Wire Label Signal Signal Reference Shield CR9000(X) CR5000 CR3000 CR1000 CR800 CR850 CR510 CR500 CR10(X) SE Analog SE Analog AG G 21X CR7 CR23X SE Analog CR200(X) SE Analog 5. Programming This section is for users who write their own datalogger programs. A datalogger program to measure this sensor can be created using Campbell Scientific's Short Cut Program Builder software. You do not need to read this section to use Short Cut. The output from the CS300 is 0.2 mV per Wm-2. The voltage signal from the CS300 is measured using the single-ended voltage instruction (VoltSE in CRBasic or Instruction 1 in Edlog). Dataloggers that use CRBasic include the CR200(X), CR800, CR850, CR1000, CR3000, CR5000, and CR9000(X). Dataloggers that use Edlog include CR7, CR10(X), CR510, and CR23X. Both CRBasic and Edlog are included in PC400 and LoggerNet datalogger support software. 4