RE-455X Control Command List RS-232 Baud Rate Data Length Parity Stop Bit Flow Control 9600 BPS 8 Bit None 2 Bit RTS/CTS control No Function 1 Local Control Mode 2 Host Control Mode Command FF 3030 00 C0 30 EF FF 3030 00 C0 31 EF 3 Focus AF 4 Focus Manual 55 ONE SHOT AF FF 3030 00 C1 30 EF FF 3030 00 C1 31 EF FF 3030 00 C1 32 EF 5 Focus Stop 6 Focus Near 7 Focus Far FF 3030 00 C2 30 EF FF 3030 00 C2 31 EF FF 3030 00 C2 32 EF 8 Zoom Stop 9 Zoom Tele 10 Zoom Wide 11 Zoom Assignment initial position 12 Zoom Assignment A4 sideway direction 13 Zoom Assignment Postcard FF 3030 00 C8 30 EF FF 3030 00 C8 31 EF FF 3030 00 C8 32 EF FF 3030 00 C9 30 EF FF 3030 00 C9 31 EF FF 3030 00 C9 32 EF 14 Zoom Position Assignment 15 Zoom Range Request 16 Zoom Position Request 17 Zoom Speed Assignment 18 Zoom Speed Request FF 3030 00 CA xx xx xx xx EF FF 3030 00 CB EF FF 3030 00 CC EF FF 3030 00 CD xx xx EF FF 3030 00 CE xx xx EF 19 Exposure Value Assignment 20 Exposure Value Request 21 Exposure Mode Nomal 22 Exposure Mode White Paper 23 Exposure Lock OFF 24 Exposure Lock ON FF 3030 00 D0 xx xx EF FF 3030 00 D1 EF FF 3030 00 D2 30 EF FF 3030 00 D2 31 EF FF 3030 00 D3 30 EF FF 3030 00 D3 31 EF 25 White Balance Auto 26 White Balance Manual 27 White Balance Value Assignment 28 White Balance Manual Value Request 29 Auto White Balance Normal 30 Auto White Balance Turbo FF 3030 00 D4 30 EF FF 3030 00 D4 31 EF FF 3030 00 D5 xx xx EF FF 3030 00 D6 EF FF 3030 00 D7 30 EF FF 3030 00 D7 31 EF 31 Still Picture OFF 32 Still Picture ON FF 3030 00 D8 30 EF FF 3030 00 D8 31 EF 33 Detail Assignment 34 Detail Request FF 3030 00 D9 xx xx EF FF 3030 00 DA EF 35 m-COM ROM Version Request 36 EEPROM Version Request FF 3030 00 DB 30 EF FF 3030 00 DB 31 EF 37 Side Light OFF 38 Side Light ON FF 3030 00 DC 30 EF FF 3030 00 DC 31 EF 39 Back Light OFF 40 Back Light ON FF 3030 00 DD 30 EF FF 3030 00 DD 31 EF 41 Input Select Camera 42 Input Select External FF 3030 00 DE 30 EF FF 3030 00 DE 31 EF 43 Command Termination Notification OFF FF 3030 00 DF 30 EF 44 Command Termination Notification ON FF 3030 00 DF 31 EF 47 Product Name Request FF 3030 00 E0 EF 48 Operation Status Request1 49 Operation Status Request2 FF 3030 00 EC 30 EF FF 3030 00 EC 31 EF 50 RE-450X Adjust Mode Change FF 3030 00 ED EF 51 Cascade ON 52 Cascade OFF 53 Global Notification ON 54 Global Notification OFF FF 3030 00 8F 31EF FF 3030 00 8F 30 EF FF 3030 00 95 31 EF FF 3030 00 95 30 EF In Case of Command Error In Case of Parameter Error Answer FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 xx xx xx xx EF FE 3030 3030 xx xx xx xx EF FE 3030 3030 EF FE 3030 3030 xx xx EF FE 3030 3030 EF FE 3030 3030 xx xx EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 xx xx EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 xx xx EF FE 3030 3030 xx xx xx xx EF FE 3030 3030 xx xx xx xx EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 xx~xx EF FE 3030 3030 xx xx EF FE 3030 3030 xx xx EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3030 EF FE 3030 3330 EF FE 3030 3530 EF Command Termination Notification Meaning To control by the main body, RE-450X (To cancel Host Control Mode) To control by host computer To change mode of focus to Auto To change mode of focus to Manual Change from Autofocus mode to Manual mode after performing Focusing FA 3030 00C2 31 EF FA 3030 00C2 32 EF To stop focus operation to near To move to near focus (when reach the end of near, make an issue of command termination notification) To move to far focus (when reach the end of far, make an issue of command termination notification) FA 3030 00C8 31 EF FA 3030 00C8 32 EF FA 3030 00C9 30 EF FA 3030 00C9 31 EF FA 3030 00C9 32 EF To stop zoom operation To zoom to tele (when reach the end of tele, make an issue of command termination notification) To zoom to wide (when reach the end of wide, make an issue of command termination notification) To move to position zoomed before zoom for "A4" or "Postcard" (issue of command termination notification) To move to zoom position for A4 sideway direction (issue of command termination notification) To move to zoom position for postcard (issue of command termination notification) FA 3030 00CA EF To move to zoom position assigned (issue of command terminationnotification) To return movable range (maximum) of zoom (movable range :0x0100(near) ~ 0x0FD4(far)) To return present zoom position To assign running speed of zoom To return present running speed of zoom To assign value of exposure (0x80 center, 0x00(bright) ~ 0xff(dark)) To request exposure value To change exposure to normal mode To change exposure to white paper mode To cancel Exposure Lock ON To lock exposure To adjust white balance automaticaly To set white balance manually To assign target value of while balance (0x80 center, 0x00(red) ~ 0xff(blue)) To return present white balance manually To change mode of auto white balance to normal To change mode of auto white balance to turbo To set still picture mode OFF To set still picture mode ON To assign detail value (0x80 center, 0x00(sharp) ~ 0xff(soft)) To return present detail value To return version value of m-COM ROM To return version value of EEPROM To switch OFF side light To switch ON side light To switch OFF back light To switch ON back light To select input from Camera To select input from externai To set termination notification OFF To set termination notification ON To return product name "xx~xx" : "52452D34353058" (RE-450X) To return information of operate status1 To return information of operate status2 To change RE-450X Adjust Mode To connect cascade connection ON To connect cascade connection OFF To set cascade global command notification ON To set cascade global command notification OFF In case of receiving the wrong commands In case of recieving parameter out of range

  • 1
  • 2

RE-455X Control Command List
RS-232
Baud Rate
9600 BPS
Data Length
8 Bit
Parity
None
Stop Bit
2 Bit
Flow Control
RTS/CTS control
No
Function
Command
Answer
Command Termination Notification
Meaning
1 Local Control Mode
FF 3030 00 C0 30 EF
FE 3030 3030 EF
To control by the main body, RE-450X
(To cancel Host Control Mode)
2 Host Control Mode
FF 3030 00 C0 31 EF
FE 3030 3030 EF
To control by host computer
3 Focus AF
FF 3030 00 C1 30 EF
FE 3030 3030 EF
To change mode of focus to Auto
4 Focus Manual
FF 3030 00 C1 31 EF
FE 3030 3030 EF
To change mode of focus to Manual
55 ONE SHOT AF
FF 3030 00 C1 32 EF
FE 3030 3030 EF
Change from Autofocus mode to Manual mode after performing Focusing
5 Focus Stop
FF 3030 00 C2 30 EF
FE 3030 3030 EF
To stop focus operation to near
6 Focus Near
FF 3030 00 C2 31 EF
FE 3030 3030 EF
FA 3030 00C2 31 EF
To move to near focus
(when reach the end of near, make an issue of command termination notification)
7 Focus Far
FF 3030 00 C2 32 EF
FE 3030 3030 EF
FA 3030 00C2 32 EF
To move to far focus
(when reach the end of far, make an issue of command termination notification)
8 Zoom Stop
FF 3030 00 C8 30 EF
FE 3030 3030 EF
To stop zoom operation
9 Zoom Tele
FF 3030 00 C8 31 EF
FE 3030 3030 EF
FA 3030 00C8 31 EF
To zoom to tele
(when reach the end of tele, make an issue of command termination notification)
10 Zoom Wide
FF 3030 00 C8 32 EF
FE 3030 3030 EF
FA 3030 00C8 32 EF
To zoom to wide
(when reach the end of wide, make an issue of command termination notification)
11 Zoom Assignment initial position
FF 3030 00 C9 30 EF
FE 3030 3030 EF
FA 3030 00C9 30 EF
To move to position zoomed before zoom for "A4" or "Postcard"
(issue of command termination notification)
12 Zoom Assignment A4 sideway direction
FF 3030 00 C9 31 EF
FE 3030 3030 EF
FA 3030 00C9 31 EF
To move to zoom position for A4 sideway direction
(issue of command termination notification)
13 Zoom Assignment Postcard
FF 3030 00 C9 32 EF
FE 3030 3030 EF
FA 3030 00C9 32 EF
To move to zoom position for postcard
(issue of command termination notification)
14 Zoom Position Assignment
FF 3030 00 CA xx xx xx xx EF
FE 3030 3030 EF
FA 3030 00CA EF
To move to zoom position assigned
(issue of command terminationnotification)
15 Zoom Range Request
FF 3030 00 CB EF
FE 3030 3030 xx xx xx xx EF
To return movable range (maximum) of zoom
(movable range :0x0100(near) ~ 0x0FD4(far))
16 Zoom Position Request
FF 3030 00 CC EF
FE 3030 3030 xx xx xx xx EF
To return present zoom position
17 Zoom Speed Assignment
FF 3030 00 CD xx xx EF
FE 3030 3030 EF
To assign running speed of zoom
18 Zoom Speed Request
FF 3030 00 CE xx xx EF
FE 3030 3030 xx xx EF
To return present running speed of zoom
19 Exposure Value Assignment
FF 3030 00 D0 xx xx EF
FE 3030 3030 EF
To assign value of exposure (0x80 center, 0x00(bright) ~ 0xff(dark))
20 Exposure Value Request
FF 3030 00 D1 EF
FE 3030 3030 xx xx EF
To request exposure value
21 Exposure Mode Nomal
FF 3030 00 D2 30 EF
FE 3030 3030 EF
To change exposure to normal mode
22 Exposure Mode White Paper
FF 3030 00 D2 31 EF
FE 3030 3030 EF
To change exposure to white paper mode
23 Exposure Lock OFF
FF 3030 00 D3 30 EF
FE 3030 3030 EF
To cancel Exposure Lock ON
24 Exposure Lock ON
FF 3030 00 D3 31 EF
FE 3030 3030 EF
To lock exposure
25 White Balance Auto
FF 3030 00 D4 30 EF
FE 3030 3030 EF
To adjust white balance automaticaly
26 White Balance Manual
FF 3030 00 D4 31 EF
FE 3030 3030 EF
To set white balance manually
27 White Balance Value Assignment
FF 3030 00 D5 xx xx EF
FE 3030 3030 EF
To assign target value of while balance (0x80 center, 0x00(red) ~ 0xff(blue))
28 White Balance Manual Value Request
FF 3030 00 D6 EF
FE 3030 3030 xx xx EF
To return present white balance manually
29 Auto White Balance Normal
FF 3030 00 D7 30 EF
FE 3030 3030 EF
To change mode of auto white balance to normal
30 Auto White Balance Turbo
FF 3030 00 D7 31 EF
FE 3030 3030 EF
To change mode of auto white balance to turbo
31 Still Picture OFF
FF 3030 00 D8 30 EF
FE 3030 3030 EF
To set still picture mode OFF
32 Still Picture ON
FF 3030 00 D8 31 EF
FE 3030 3030 EF
To set still picture mode ON
33 Detail Assignment
FF 3030 00 D9 xx xx EF
FE 3030 3030 EF
To assign detail value (0x80 center, 0x00(sharp) ~ 0xff(soft))
34 Detail Request
FF 3030 00 DA EF
FE 3030 3030 xx xx EF
To return present detail value
35 m-COM ROM Version Request
FF 3030 00 DB 30 EF
FE 3030 3030 xx xx xx xx EF
To return version value of m-COM ROM
36 EEPROM Version Request
FF 3030 00 DB 31 EF
FE 3030 3030 xx xx xx xx EF
To return version value of EEPROM
37 Side Light OFF
FF 3030 00 DC 30 EF
FE 3030 3030 EF
To switch OFF side light
38 Side Light ON
FF 3030 00 DC 31 EF
FE 3030 3030 EF
To switch ON side light
39 Back Light OFF
FF 3030 00 DD 30 EF
FE 3030 3030 EF
To switch OFF back light
40 Back Light ON
FF 3030 00 DD 31 EF
FE 3030 3030 EF
To switch ON back light
41 Input Select Camera
FF 3030 00 DE 30 EF
FE 3030 3030 EF
To select input from Camera
42 Input Select External
FF 3030 00 DE 31 EF
FE 3030 3030 EF
To select input from externai
43 Command Termination Notification OFF
FF 3030 00 DF 30 EF
FE 3030 3030 EF
To set termination notification OFF
44 Command Termination Notification ON
FF 3030 00 DF 31 EF
FE 3030 3030 EF
To set termination notification ON
47 Product Name Request
FF 3030 00 E0 EF
FE 3030 3030 xx~xx EF
To return product name ”xx~xx” : ”52452D34353058” (RE-450X)
48 Operation Status Request1
FF 3030 00 EC 30 EF
FE 3030 3030 xx xx EF
To return information of operate status1
49 Operation Status Request2
FF 3030 00 EC 31 EF
FE 3030 3030 xx xx EF
To return information of operate status2
50 RE-450X Adjust Mode Change
FF 3030 00 ED EF
FE 3030 3030 EF
To change RE-450X Adjust Mode
51 Cascade ON
FF 3030 00 8F 31EF
FE 3030 3030 EF
To connect cascade connection ON
52 Cascade OFF
FF 3030 00 8F 30 EF
FE 3030 3030 EF
To connect cascade connection OFF
53 Global Notification ON
FF 3030 00 95 31 EF
FE 3030 3030 EF
To set cascade global command notification ON
54 Global Notification OFF
FF 3030 00 95 30 EF
FE 3030 3030 EF
To set cascade global command notification OFF
In Case of Command Error
FE 3030 3330 EF
In case of receiving the wrong commands
In Case of Parameter Error
FE 3030 3530 EF
In case of recieving parameter out of range