Canon LV-7545 Command List - Page 2
CR0 43h, CR1 43h, CR3 43h, CR4 43h, CR6 43h, 1. Power Status, 2. Input mode Read, 3. Lamp time,
View all Canon LV-7545 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
2. Status Read Command Command ASCII HEX CR0 43h 52h 30h Power Status Read CR1 43h 52h 31h Input mode Read CR3 43h 52h 33h Lamp time Read CR4 43h 52h 34h Setting Read CR6 43h 52h 36h Temp. Read Function 2-1. Power Status Command ASCII HEX 00 30h 30h 80 38h 30h 40 34h 30h 20 32h 30h 10 31h 30h 28 32h 38h 08 30h 38h 88 38h 38h 02 30h 32h 24 32h 34h 04 30h 34h Status Power ON Stand by Count down Cooling down Power abnormality Temperature abnormality-occur during cleaning Temperature abnormality-general problem Temperature abnormality-standby, both above abnormalities occurred Key input prohibition Power Management Cooling Power Management 2-2. Input mode Read Command ASCII HEX 0 30h Input-1 mode 1 31h Input-2 mode 2 32h Input-3 mode Status 2-3. Lamp time Command **** Status 4 digit 2-4. Setting Command ASCII HEX 11 31h 31h 10 31h 30h 01 30h 31h 00 30h 30h Normally Top/Bottom reversal Left/Right reversal Top/Bottom & Left/Right Status 2-5. Temp Command Status Temperature value there are 3 temperature sensors (each represented as _**.* or eg. 89.2 which is 89.2 degrees. If temperature error occurs, the letter "E" should/would be placed where the "_" occurs before the **.*