Canon LV-S1 Command List - Page 2

Status Read, Status Read Command - lamp

Page 2 highlights

C3E C3F C43 C44 C89 C8A C8E C8F 43h 33h 45h 43h 33h 46h 43h 34h 33h 43h 34h 34h 43h 38h 39h 43h 38h 41h 43h 38h 45h 43h 38h 46h Right click Select Freeze ON Freeze OFF Auto PC Adj. Presentation Timer Keystone + Keystone - 2. Status Read Command Command ASCII HEX CR0 43h 52h 30h Status Read CR1 43h 52h 31h Input mode Read CR3 43h 52h 33h Lamp time Read CR4 43h 52h 34h Setting Read CR6 43h 52h 36h Temp. Read Function 2-1.Status Read Command ASCII HEX 00 30h 30h 80 38h 30h 40 34h 30h 20 32h 30h 10 31h 30h 28 32h 38h 08 30h 38h 88 38h 38h 02 30h 32h Status Power ON Stand by Count down Cooling down Power abnormality Temperature abnormality-occur during cleaning Temperature abnormality-general problem Temperature abnormality-standby, both above abnormalities occurred Key input prohibition

  • 1
  • 2
  • 3

C3E
43h
33h
45h
Right click
C3F
43h
33h
46h
Select
C43
43h
34h
33h
Freeze ON
C44
43h
34h
34h
Freeze OFF
C89
43h
38h
39h
Auto PC Adj.
C8A
43h
38h
41h
Presentation Timer
C8E
43h
38h
45h
Keystone +
C8F
43h
38h
46h
Keystone -
ASCII
HEX
CR0
43h
52h
30h
Status Read
CR1
43h
52h
31h
Input mode Read
CR3
43h
52h
33h
Lamp time Read
CR4
43h
52h
34h
Setting Read
CR6
43h
52h
36h
Temp. Read
2-1.Status Read
ASCII
HEX
00
30h
30h
Power ON
80
38h
30h
Stand by
40
34h
30h
Count down
20
32h
30h
Cooling down
10
31h
30h
Power abnormality
28
32h
38h
Temperature abnormality-occur during cleaning
08
30h
38h
Temperature abnormality-general problem
88
38h
38h
Temperature abnormality-standby, both above abnormalities occurred
02
30h
32h
Key input prohibition
2. Status Read Command
Command
Function
Command
Status