Canon PC150 PC160 Operator's Manual - Page 53
Cleaning the fiber lens, reverse side
UPC - 013803046014
View all Canon PC150 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 53 highlights
Troubleshooting Cleaning the fiber lens (reverse side) Open the top cover and remove the cartridge. (See "Replacing Cartridges", on p.21.) MEMO: Clean the reverse side of the fiber lens. To clean, run a cotton swab lightly over the entire length of the lens several times. • When cleaning the fiber lens be sure to use the flat type of cotton swab that is normally used for cleaning audio equipment. A round cotton swab will not fit into the groove properly. • Do not soak the cotton swabs in any type of cleaning solution or alcohol before using them to clean the fiber lens. Only use dry cotton swabs. • If the above procedure fails to remedy the copy image problems, contact your dealer or service representative. 3 Fiber lens (reverse side) Once the cleaning is complete replace the cartridge, close the top cover and slide the plate back into the center position. Copy Image Problems 03/ PC160-USA 51 51 05.2.1, 18:45