Casio PCR T265 Owners Manual - Page 3
Specifications - manual
UPC - 079767505981
View all Casio PCR T265 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
1. SPECIFICATIONS 1-1. Electrical specifications 120 V 220 V 230 V • Power consumption In operation Max. 0.22 A 0.13 A 0.13 A • Memory protection Back-up battery Back-up period Battery life Mangan Battery (UM-3 × 3 pcs) 1 year (25 °C) Replace the battery every 1 years. • Clock & Calendar Accuracy Auto calendar Within ± 30 sec. per month Effective until 2099 A.D. 240 V 0.13 A 1-2. Environmental specifications • Operating temperature • Operating humidity • Storage temperature • Storage humidity • Vibration strength 0 °C ~ 40 °C 10 % ~ 90 % -25 °C ~ 65 °C 10 % ~ 95 % 1.5 G (The machine must be in the carton box) 1-3. Main components • CPU Name • Thermal printer • Roll paper Number of control bit Mask ROM (Built-in) RAM (Built-in) Name Print method Head specification Paper cut Paper supply method Life Type Size Roll diam Thickness UK: µPD784215AGC2368EU U.S.A./CANADA: µPD784215AGC2378EU Other countries: µPD784215AGC2388EU 16 bit 128 Kbytes 5120 bytes LTPZ225B-C192 Impression heat line dot Total dot number : 192 dots/dot line Dot pitch : Length 4 dots/mm Wide 4 dots/mm Manual-paper cut Drop-in paper loading 20 million pulses 10 km (anti-abrasion) Heat-sensitive paper 58 +0/-1 mm φ 80 or less 75 ± 3µm - 1 -