Celestron WindGuide Plus Anemometer Green WindGuide Plus Anemometer Instructio - Page 1

Celestron WindGuide Plus Anemometer Green Manual

Page 1 highlights

INSTRUCTION MANUAL MODELS #48025 AND #48026 1. Functions of the WindGuide Plus The basic functions of the WindGuide Plus are measurements of Wind (Air) Speed, Temperature, Wind Chill Factor, Humidity, Barometric Pressure and Altitude. You can also check the Date and Time and choose HOLD, MAX or MIN for the measurement functions. A Backlight feature can be used in the dark and an Auto Off feature is standard. The settings you have made will remain valid until you change the settings or the battery is replaced. When replacing the battery, you will have to reset all the settings. 3. Operating the WindGuide Plus After the Initial Set Up is complete, you can now operate the WindGuide Plus. 3.1 Press to switch the unit on 2. Initial Set Up To activate open battery door and pull the tab out. Replace door and turn power off. While the unit is off, press and hold down (for a few seconds) and press to enter the mode of your initialization settings. 2.1 Set the Date and Time Date display = Day: Month: Year (e.g., 25:10:12) Time display = Hour: Minute: Second (e.g.,23:35:45) First set the date - a default date will display on the screen. Press to adjust the day, and press to confirm after each adjustment - day/month/year. After the date is set, the unit automatically goes to the Time setting. Note: The time display is only available in a 24 hour format. Set the hour/minutes/seconds using the button, and press to confirm after each setting. 2.2 Set Wind/Air speed units = m/s (meters per second), mph (miles per hour), fps (feet per second), km/h (kilometers per hour), knots - wind conversions readily available on the Internet The default is m/s. Press to find the desired unit and press to confirm. 2.3 Set the Temperature unit setting of ºC or ºF. Press to find the desired unit and press to confirm 2.4 Set Humidity = the humidity is a fixed measurement showing percentage of relative humidity. Press to proceed to the next setting 2.5 Set Barometer units = barometric pressure can be measured with inHg (inches of mercury) or hPa (hectopascals). Press to find the desired unit and press to confirm 2.6 Set Altitude = choose m (meters) or ft (feet). Press to find the desired unit and press to confirm. The WindGuide Plus turns off automatically after all the settings are complete. 3.2 Display a desired function Press for 3 seconds to choose from Wind/Air Speed Temperature Wind Chill (the felt air temperature on exposed skin due to the wind) Humidity. Press repeatedly until the desired function displays on the LCD screen. Press for 3 seconds to choose from Time Barometric Pressure Altitude. Press repeatedly until the desired function displays on the LCD screen. 3.3 Hold the current reading and display the MAX and MIN value. Hold the current reading at any time by pressing . Press again to display the MAX and MIN value since the unit was turned on. Note: The MAX and MIN values will not be kept in the unit's memory once it goes off. 3.4 Date - can be seen momentarily when turning the unit on 3.5 Backlight Press and at the same time for 3 seconds to turn the backlight on. It will shut off automatically after 20 seconds. 3.6 Turn the unit off Auto Shut Off = the unit goes off automatically after 5 minutes idle. Manually = Press and at the same time for 6 seconds. 4. Specifications Wind/Air Speed = up to 108 km/h or 67 mph; 30 ms or 98 fps or 58 knots Temperature = -10~60ºC / 14~140ºF Humidity = 5%~95%RH (Relative Humidity) Barometric Pressure = 300 to 1200 hPa /inHg 8.9 to 34.5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

1. Functions of the
WindGuide Plus
The basic functions of the
WindGuide Plus are
measurements of Wind (Air)
Speed, Temperature, Wind Chill
Factor,
Humidity,
Barometric
Pressure and Altitude. You can
also check the Date and Time
and choose HOLD, MAX or MIN
for the measurement functions.
A Backlight feature can be used
in the dark and an Auto Off fea-
ture is standard.
2. Initial Set Up
To activate open battery door
and pull the tab out. Replace
door and turn power off.
While the unit is off,
press
and hold down (for a few sec-
onds) and
press
to enter the
mode of your initialization set-
tings.
2.1
Set the Date and Time
Date display = Day: Month: Year
(e.g., 25:10:12)
Time display = Hour: Minute:
Second (e.g.,23:35:45)
First set the date – a default
date will display on the screen. Press
to adjust the day, and press
to confirm after each adjustment – day/month/year.
After the date is set, the unit automatically goes to the Time setting.
Note:
The time display is only available in a 24 hour format. Set the
hour/minutes/seconds using the
button, and press
to confirm after
each setting.
2.2
Set Wind/Air speed units = m/s (meters per second), mph (miles
per hour), fps (feet per second), km/h (kilometers per hour), knots –
wind conversions readily available on the Internet
The default is m/s. Press
to find the desired unit and press
to
confirm.
2.3
Set the Temperature unit setting of ºC or ºF. Press
to find the
desired unit and press
to confirm
2.4
Set Humidity = the humidity is a fixed measurement showing per-
centage of relative humidity. Press
to proceed to the next setting
2.5
Set Barometer units = barometric pressure can be measured with
inHg (inches of
mercury) or hPa (hectopascals). Press
to find the desired unit and
press
to confirm
2.6
Set Altitude = choose m (meters) or ft (feet). Press
to find the
desired unit and press
to confirm.
The WindGuide Plus turns off automatically after all the settings are com-
plete.
The settings you have made will remain valid until you change the
settings or the battery is replaced. When replacing the battery, you will
have to reset all the settings.
3. Operating the WindGuide Plus
After the Initial Set Up is complete, you can now operate the WindGuide
Plus.
3.1
Press
to switch the unit on
3.2
Display a desired function
Press
for 3 seconds to choose from Wind/Air Speed
Temperature
Wind Chill
(the felt air temperature on exposed skin due to the
wind)
Humidity. Press
repeatedly until the desired function dis-
plays on the LCD screen.
Press
for 3 seconds to choose from Time
Barometric Pressure
Altitude. Press
repeatedly until the desired
function displays on the LCD screen.
3.3
Hold the current reading and display the MAX and MIN value.
Hold the current reading at any time by pressing
. Press again to
display the MAX and MIN value since the unit was turned on.
Note:
The MAX and MIN values will not be kept in the unit’s memory
once it goes off.
3.4
Date – can be seen momentarily when turning the unit on
3.5
Backlight
Press
and
at the same time for 3 seconds to turn the backlight on.
It will shut off automatically after 20 seconds.
3.6
Turn the unit off
Auto Shut Off = the unit goes off automatically after
5 minutes idle.
Manually = Press
and
at the same time for 6 seconds.
4. Specifications
Wind/Air Speed = up to 108 km/h or 67 mph;
30 ms or 98 fps or 58 knots
Temperature = -10~60ºC / 14~140ºF
Humidity = 5%~95%RH (Relative Humidity)
Barometric Pressure = 300 to 1200 hPa /inHg 8.9 to 34.5
INSTRUCTION MANUAL
MODELS
#48025
AND #48026