Cisco 2960 8TC Hardware Installation Guide - Page 101

Catalyst 2924 XL, Table A-2 - dimensions

Page 101 highlights

Appendix A Technical Specifications Table A-2 Technical Specifications for the Catalyst 2924 XL and Catalyst 2924C XL Switches Catalyst 2924 XL Environmental Operating Ranges Operating temperature 32 to 113°F (0 to 45°C) Storage temperature -4 to 149°F (-10 to 65°C) Operating humidity 10 to 85% (noncondensing) Operating altitude Up to 10,000 ft (3000 m) Storage altitude Power Requirements Up to 15,000 ft (4570 m) AC input voltage DC input voltages 100 to 127/200 to 240 VAC (autoranging) 50 to 60 Hz +5V @9A, +12V @0.5A Power consumption 70W (maximum) Physical Dimensions 239 Btus per hour Weight 7 lb (3.2 kg) Dimensions (H x W x D) Fiber-Port Power Levels 1.73 x 17.5 x 9.79 in. (4.4 x 44.5 x 24.8 cm) Optical transmitter - wavelength Optical sensibility of the - receiver Optical power transmitter - Transmit - 1. nm = nanometers 2. dBm = decibel milliwatt Catalyst 2924C XL 32 to 113°F (0 to 45°C) -4 to 149°F (-10 to 65°C) 10 to 85% (noncondensing) Up to 10,000 ft (3000 m) Up to 15,000 ft (4570 m) 100 to 127/200 to 240 VAC (autoranging) 50 to 60 Hz +5V @9A, +12V @0.5A 70W (maximum) 239 Btus per hour 7 lb (3.2 kg) 1.73 x 17.5 x 9.79 in. (4.4 x 44.5 x 24.8 cm) 1300 nm1 -14 dBm2 -19 to -14 dBm -19 to -14 dBm 78-6461-04 Catalyst 2900 Series XL Hardware Installation Guide A-3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162

A-3
Catalyst 2900 Series XL Hardware Installation Guide
78-6461-04
Appendix A
Technical Specifications
Table A-2
Technical Specifications for the Catalyst 2924 XL and Catalyst 2924C XL Switches
Catalyst 2924 XL
Catalyst 2924C XL
Environmental Operating Ranges
Operating temperature
32 to 113°F (0 to 45°C)
32 to 113°F (0 to 45°C)
Storage temperature
–4 to 149°F (–10 to 65°C)
–4 to 149°F (–10 to 65°C)
Operating humidity
10 to 85% (noncondensing)
10 to 85% (noncondensing)
Operating altitude
Up to 10,000 ft (3000 m)
Up to 10,000 ft (3000 m)
Storage altitude
Up to 15,000 ft (4570 m)
Up to 15,000 ft (4570 m)
Power Requirements
AC input voltage
100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz
100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz
DC input voltages
+5V
@9A,
+
12V
@0.5A
+5V
@9A,
+
12V
@0.5A
Power consumption
70W (maximum)
239
Btus per hour
70W (maximum)
239 Btus per hour
Physical Dimensions
Weight
7 lb (3.2 kg)
7 lb (3.2 kg)
Dimensions (H x W x D)
1.73 x 17.5 x 9.79 in.
(4.4 x 44.5 x 24.8 cm)
1.73 x 17.5 x 9.79 in.
(4.4 x 44.5 x 24.8 cm)
Fiber-Port Power Levels
Optical transmitter
wavelength
1300 nm
1
Optical sensibility of the
receiver
–14 dBm
2
Optical power transmitter
–19 to –14 dBm
Transmit
–19 to –14 dBm
1.
nm = nanometers
2.