Clifford Concept 450 Owners Guide - Page 18
disarming diagnostics, arm/disarm diagnostic chart
View all Clifford Concept 450 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
tem will monitor that input normally. For example, if your vehicle has interior light exit delay, and you arm the system before the interior light goes out, you may hear Bypass Notification chirps. Once the light shuts off, however, the doors are monitored normally. disarming diagnostics Extra disarm chirps are the Tamper Alert. If three chirps are heard when disarming, the system was triggered in your absence. If three chirps are heard, the LED status indicator will indicate which zone was involved when you turn the ignition on (see the Table of Zones section). The system will retain this information in its memory. Refer to the Multiple Event Total Recall section of this guide. arm/disarm diagnostic chart Action Arm Arm Chirps 2 4 Light Flashes 2 4 Arm 2 (5 sec.) 4 2 (5 sec.) 4 Arm 2 (10 sec.) 4 2 (10 sec.) 4 Disarm 1 1 Disarm 3 3 Description System armed System armed with hood/ trunk active and bypassed (zones 5 and 6) System armed with door active and bypassed (zone 4) System armed with sensor active and bypassed zones 1, 3, and 8 System disarmed System disarmed with tamper alert © 2004 directed electronics, inc. 15