Creative Sound Blaster Tactic360 Ion SB Tactic360 Ion FCC cert and report - Page 6

Equipments Used during Test

Page 6 highlights

Test Report No. 2024608/EE Date : Sep 08 2011 Page 6 of 19 Equipments Used during Test Conducted Emission Item Test Equipment Manufacturer Model No. Inventory Cal.Date No. (yyyy-mm-dd) 1 Shielding Room ZhongYu Electron GB-88 SEL0042 2011-06-10 2 LISN Rohde & Schwarz ENV216 SEL0152 2010-10-27 3 8 Line ISN Fischer Custom Communications FCC-TLISN-T8-02 EMC0120 2011-01-17 Inc. 4 4 Line ISN Fischer Custom Communications FCC-TLISN-T4-02 EMC0121 2011-01-17 Inc. 5 2 Line ISN Fischer Custom Communications FCC-TLISN-T2-02 EMC0122 2011-01-17 Inc. 6 EMI Test Receiver Rohde & Schwarz ESCI SEL0022 2011-05-26 7 Coaxial Cable SGS N/A SEL0024 2011-05-29 Cal.Due date (yyyy-mm-dd) 2012-06-10 2011-10-26 2012-01-17 2012-01-17 2012-01-17 2012-05-26 2012-05-29 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company's findings at the time of its intervention only and within the limits of Client's instructions, if any. The Company's sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only. SGS Hong Kong Ltd. 5/F - 8/F & 28/F -29/F, Metropole Square, 2 On Yiu Street, Siu Lek Yuen, Shatin, N.T., Hong Kong. t (852) 2334 4481-9 f (852) 2764 3126 www.hk.sgs.com Member of the SGS Group (SGS SA)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19

Test Report
No. 2024608/EE
Date : Sep 08 2011
Page 6 of
19
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm
and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm
.
Attention is drawn to the limitation of liability, indemnification and
jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested
and such sample(s) are retained for 30 days only
.
SGS Hong Kong Ltd. 5/F - 8/F & 28/F -29/F, Metropole Square, 2 On Yiu Street, Siu Lek Yuen, Shatin, N.T., Hong Kong.
t
(852) 2334 4481-9
f
(852) 2764 3126 www.hk.sgs.com
Member of the SGS Group (SGS SA)
Equipments Used during Test
Conducted Emission
Item Test Equipment
Manufacturer
Model No.
Inventory
No.
Cal.Date
(yyyy-mm-dd
)
Cal.Due date
(yyyy-mm-dd
)
1
Shielding Room
ZhongYu Electron
GB-88
SEL0042
2011-06-10
2012-06-10
2
LISN
Rohde & Schwarz ENV216
SEL0152
2010-10-27
2011-10-26
3
8 Line ISN
Fischer
Custom
Communications
Inc.
FCC-TLISN-T8-02 EMC0120
2011-01-17
2012-01-17
4
4 Line ISN
Fischer
Custom
Communications
Inc.
FCC-TLISN-T4-02 EMC0121
2011-01-17
2012-01-17
5
2 Line ISN
Fischer
Custom
Communications
Inc.
FCC-TLISN-T2-02 EMC0122
2011-01-17
2012-01-17
6
EMI Test Receiver Rohde & Schwarz ESCI
SEL0022
2011-05-26
2012-05-26
7
Coaxial Cable
SGS
N/A
SEL0024
2011-05-29
2012-05-29