CyberPower AVRG900U User Manual - Page 2

Definitions For Led Indicators & Audible Alarms

Page 2 highlights

5 REPLACING THE BATTERY - continued 8. Install the replacement battery by connecting the red wire and black wire to the positive (+) and negative (-) terminal of the battery. 9. Put the battery back into the compartment. 10. Slide back the battery compartment cover and tighten the retaining screw. 11. Charge the unit for 8 hours to fully charge the battery. REMINDER: Batteries are considered HAZARDOUS WASTE and must be disposed of properly. Most retailers that sell lead acid batteries collect used batteries for recycling, as required by local regulations SYSTEM FUNCTION BLOCK DIAGRAM Input EMI Filter Surge Suppressor AVR Output Normal Mode Battery Mode Charger AC / DC Inverter Battery TROUBLESHOOTING Problem Possible Cause Full-time surge protection outlets stop providing power to equipment. Circuit breaker button is projecting from the side of the unit. Circuit breaker has been tripped due to an overload. The UPS does not perform expected runtime. Battery not fully charged. Battery is worn out. The on/off switch is designed to prevent damage from rapidly turning it off and on. The unit is not connected to an AC outlet. The UPS will not turn on. The battery is worn out. Mechanical problem. The frequency is outside of the operating range of 57-63Hz. Solution Turn the UPS off and unplug at least one piece of equipment. Wait 10 seconds, reset the circuit breaker by pressing the button, and then turn the UPS on. Recharge the battery by leaving the UPS plugged in. Contact CyberPower Systems about replacement batteries at: cyberpowersystems.com/support. Turn the UPS off. Wait 10 seconds and then turn the UPS on. The unit must be connected to a 120V 60Hz outlet. Contact CyberPower Systems about replacement batteries at: cyberpowersystems.com/support. Contact CyberPower Systems at: cyberpowersystems.com/support. Turn the UPS off. Make sure the frequency range is within 57-63Hz. Or you can turn the UPS on in battery mode. TROUBLESHOOTING - continued Problem Possible Cause The USB cable is not connected. 6 Solution Connect the USB cable to the UPS unit and an open USB port on the back of the computer. PowerPanel® Personal is inactive (all icons are gray). The USB cable is connected to a bad USB port. Check for a different USB port and plug the cable in. The unit is not providing battery power. Shutdown your computer and turn the UPS off. Wait 10 seconds and turn the UPS back on. This should reset the unit. Additional troubleshooting information can be found at "Support" at www.CyberPowerSystems.com DEFINITIONS FOR LED INDICATORS & AUDIBLE ALARMS POWER i FAULT ALARM CONDITION On Off Off Normal On* Off Beep twice every 30 seconds Utility Failure - The UPS is providing power to battery power-supplied outlets from its battery. On* On/Off Off On Off Flash once every 5 seconds Flash once every 5 seconds Flash 3 times every 5 seconds Rapid beeping every 1/2 second Constant tone Constant tone Utility Failure - The UPS is providing battery power. Rapid beeping indicates the unit will run out of power soon Battery Mode or AC/Utility Power Mode Overload Fault Occurs when connected equipment exceeds the rating of battery outlets of the unit. Please unplug at least one piece of equipment from battery outlets. Battery Output Short Fault - Please unplug at least one piece of equipment from battery outlets and turn on the UPS again. If the fault still exists, please contact CyberPower Systems for support. Constant tone Charger Fault - Contact CyberPower Systems for support. * The Power On LED will flash when UPS alarm is beeping. TECHNICAL SPECIFICATIONS Model AVRG750U Capacity Nominal Input Voltage Input Frequency On-Battery Output Voltage Automatic Voltage Regulator (AVR) 750VA / 450W On-Battery Output Frequency 120Vac 60 Hz ± 3 Hz 120Vac ± 5% Yes 60Hz +/- 1% AVRG900U 900VA / 480W Max. Load for UPS Outlets Max. Load for Full-Time Surge Protection Outlets On-Battery Output Wave Form 750VA / 450W 900VA / 480W 12 Amps Simulated Sine Wave Operating Temperature + 32°F to 104°F / 0°C to 40°C Operating Relative Humidity 0 to 90% non-condensing Size (W x H x D) 12.2" x 7" x 3.5" Net Weight 13.44 lbs 14.04 lbs Typical Battery Recharge Time 8 hours typical from total discharge Typical Battery Life 3 to 6 years, depending on number of discharge/recharge cycles Recommended Battery Sealed Maintenance-Free Lead Acid Battery Safety Approvals UL1778(UPS), cUL107., FCC/DoC Class B CYBERPOWER GREENPOWER UPS™ TECHNOLOGY Advanced Energy-Saving Patented Bypass Technology CyberPower's patented GreenPower UPS™ with Bypass Technology reduces UPS energy costs by up to 75% compared to conventional UPS models. Even when utility power is normal, conventional UPS models constantly pass power through a transformer. By contrast, under normal conditions the advanced circuitry of a GreenPower UPS™ bypasses the transformer. As a result, the power efficiency is significantly increased while decreasing waste heat, using less energy, and reducing energy costs. When an abnormal power condition occurs, the GreenPower UPS™ automatically runs power through its transformer to regulate voltage and provide "safe" power. Since utility power is normal over 88% of the time, the GreenPower UPS™ operates primarily in its efficient bypass mode. The GreenPower UPS™ is also manufactured in accordance with the Restriction on Hazardous Substances (RoHS) directive making it one of the most environmentally-friendly on the market today. GREENPOWER UPS™ Energy-Saving Technology FCC COMPLIANCE STATEMENT This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Canadian Compliance Statement CAN ICES-3 (B)/NMB-3(B) LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE Please visit www.CyberPowerSystems.com for a copy of the Limited Warranty and Connected Equipment Guarantee. Where Can I Get More Information? The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded. CyberPower is the warrantor under this Limited Warranty. For further information please feel free to contact CyberPower at: Cyber Power Systems (USA), Inc. 4241 12th Ave E., STE 400, Shakopee, MN 55379; call us at (877) 297-6937; or submit a web ticket online at cyberpowersystems.com/support. Cyber Power Systems (USA), Inc. encourages environmentally sound methods for disposal and recycling of its UPS products. Please dispose and/or recycle your UPS and batteries in accordance to the local regulations of your state. WARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene, which is known to the State of California to cause reproductive harm and cancer. For more information, go to www.P65Warnings.ca.gov. © 2021 CyberPower Systems (USA), Inc. PowerPanel® Personal is a trademark of Cyber Power Systems(USA) Inc. All rights reserved. All other trademarks are the property of their respective owners. 7 8

  • 1
  • 2

8. Install the replacement battery by
connecting the red wire and black wire to
the positive (+) and negative (-) terminal of
the battery.
9. Put the battery back into the compartment.
10. Slide back the battery compartment cover
and tighten the retaining screw.
11. Charge the unit for 8 hours to fully charge
the battery.
REMINDER:
Batteries are considered HAZARDOUS
WASTE and must be disposed of properly.
Most retailers that sell lead acid batteries
collect used batteries for recycling, as
required by local regulations
SYSTEM FUNCTION BLOCK DIAGRAM
TROUBLESHOOTING
- continued
Problem
Possible Cause
Solution
Full-time surge protection
outlets stop providing power
to equipment. Circuit breaker
button is projecting from the side
of the unit.
Circuit breaker has been tripped
due to an overload.
Turn the UPS off and unplug at
least one piece of equipment.
Wait 10 seconds, reset the circuit
breaker by pressing the button,
and then turn the UPS on.
The UPS does not perform
expected runtime.
Battery not fully charged.
Recharge the battery by leaving
the UPS plugged in.
Battery is worn out.
Contact CyberPower Systems
about replacement batteries at:
cyberpowersystems.com/support.
The UPS will not turn on.
The on/off switch is designed
to prevent damage from rapidly
turning it off and on.
Turn the UPS off. Wait 10 seconds
and then turn the UPS on.
The unit is not connected to an
AC outlet.
The unit must be connected to a
120V 60Hz outlet.
The battery is worn out.
Contact CyberPower Systems
about replacement batteries at:
cyberpowersystems.com/support.
Mechanical problem.
Contact CyberPower Systems at:
cyberpowersystems.com/support.
The frequency is outside of the
operating range of 57-63Hz.
Turn the UPS off. Make sure the
frequency range is within 57-63Hz.
Or you can turn the UPS on in
battery mode.
Additional troubleshooting information can be found at “Support” at www.CyberPowerSystems.com
* The Power On LED will flash when UPS alarm is beeping.
POWER
i
FAULT
ALARM
CONDITION
On
Off
Off
Normal
On*
Off
Beep twice
every 30 seconds
Utility Failure -
The UPS is providing power to
battery power-supplied outlets from its battery.
On*
Off
Rapid beeping
every 1/2 second
Utility Failure -
The UPS is providing battery power. Rapid
beeping indicates the unit will run out of power soon
On/Off
Flash once
every 5
seconds
Constant tone
Battery Mode or AC/Utility Power Mode Overload Fault -
Occurs when connected equipment exceeds the rating of
battery outlets of the unit. Please unplug at least one piece
of equipment from battery outlets.
Off
Flash once
every 5
seconds
Constant tone
Battery Output Short Fault -
Please unplug at least one
piece of equipment from battery outlets and turn on the
UPS again. If the fault still exists, please contact
CyberPower Systems for support.
On
Flash 3
times
every 5
seconds
Constant tone
Charger Fault -
Contact CyberPower Systems for support.
DEFINITIONS FOR LED INDICATORS & AUDIBLE ALARMS
REPLACING THE BATTERY
- continued
TROUBLESHOOTING
Problem
Possible Cause
Solution
PowerPanel® Personal is inactive
(all icons are gray).
The USB cable is not connected.
Connect the USB cable to the UPS
unit and an open USB port on the
back of the computer.
The USB cable is connected to a
bad USB port.
Check for a different USB port and
plug the cable in.
The unit is not providing battery
power.
Shutdown your computer and turn
the UPS off. Wait 10 seconds and
turn the UPS back on. This should
reset the unit.
TECHNICAL SPECIFICATIONS
Model
AVRG750U
AVRG900U
Capacity
750VA / 450W
900VA / 480W
Nominal Input Voltage
120Vac
Input Frequency
60 Hz ± 3 Hz
On-Battery Output Voltage
120Vac ± 5%
Automatic Voltage Regulator
(AVR)
Yes
On-Battery Output Frequency
60Hz +/- 1%
Max. Load for UPS Outlets
750VA / 450W
900VA / 480W
Max. Load for Full-Time Surge
Protection Outlets
12 Amps
On-Battery Output Wave Form
Simulated Sine Wave
Operating Temperature
+ 32°F to 104°F / 0°C to 40°C
Operating Relative Humidity
0 to 90% non-condensing
Size (W x H x D)
12.2” x 7” x 3.5”
Net Weight
13.44 lbs
14.04 lbs
Typical Battery Recharge Time
8 hours typical from total discharge
Typical Battery Life
3 to 6 years, depending on number of discharge/recharge cycles
Recommended Battery
Sealed Maintenance-Free Lead Acid Battery
Safety Approvals
UL1778(UPS), cUL107., FCC/DoC Class B
Advanced Energy-Saving Patented Bypass Technology
CyberPower’s patented GreenPower UPS™ with Bypass Technology reduces UPS energy costs by up to 75% compared to conventional
UPS models. Even when utility power is normal, conventional UPS models constantly pass power through a transformer. By contrast,
under normal conditions the advanced circuitry of a GreenPower UPS™ bypasses the transformer. As a result, the power efficiency is
significantly increased while decreasing waste heat, using less energy, and reducing energy costs. When an abnormal power condition
occurs, the GreenPower UPS™ automatically runs power through its transformer to regulate voltage and provide “safe” power.
Since utility power is normal over 88% of the time, the GreenPower UPS™ operates primarily in its efficient bypass mode. The GreenPower
UPS™ is also manufactured in accordance with the Restriction on Hazardous Substances (RoHS) directive making it one of the most
environmentally-friendly on the market today.
CYBERPOWER GREENPOWER UPS™ TECHNOLOGY
G
REEN
P
OWER
UPS
Energy-Saving Technology
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warning:
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Canadian Compliance Statement
CAN ICES-3 (B)/NMB-3(B)
FCC COMPLIANCE STATEMENT
Please visit www.CyberPowerSystems.com for a copy of the Limited Warranty and Connected Equipment Guarantee.
Where Can I Get More Information?
The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded.
CyberPower is the warrantor under this Limited Warranty. For further information please feel free to contact CyberPower at:
Cyber Power Systems (USA), Inc.
4241 12th Ave E., STE 400, Shakopee, MN 55379;
call us at
(877) 297-6937
; or submit a web ticket online at
cyberpowersystems.com/support
.
Cyber Power Systems (USA), Inc. encourages environmentally sound methods for disposal and recycling of its UPS products.
Please dispose and/or recycle your UPS and batteries in accordance to the local regulations of your state.
WARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene, which is known to the State of California
to cause reproductive harm and cancer. For more information, go to www.P65Warnings.ca.gov.
LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE
© 2021 CyberPower Systems (USA), Inc. PowerPanel® Personal is a trademark of Cyber Power Systems(USA) Inc.
All rights reserved. All other trademarks are the property of their respective owners.
6
7
8
5
Input
Output
Battery Mode
Normal Mode
EMI
Filter
Surge
Suppressor
Inverter
Charger
AC / DC
Battery
AVR