CyberPower OL6KRT Quick Start Guide - Page 1

CyberPower OL6KRT Manual

Page 1 highlights

RACKMOUNT INSTALLATION UPS INPUT/OUTPUT ELECTRICAL CONNECTION OL6KRT/OL8KRT/OL10KRT/ QUICK START GUIDE UNPACKING 1 2 3 4 1. Install rack mount ears using eight M5X7L flat head screws and hanging brackets using six M5X6L pan head screws. 2. Locate space where the UPS will be installed in the rack. 3. Install rack mount rails using eight M5X6L pan head screws with plastic washers and adjust rails to necessary rack depth. 4. Place and secure the UPS on to the rack mount rails using four M5X12L pan head screws. 1 2 Rack mount ear 3 4U 9 8 3U 7 6 5 2U 4 3 2 1U 1 Rack mount rail Note: Repeat these steps with the Extended Battery Module. 4 TOWER INSTALLATION 5 6 7 8 1. Adhere eight circular rubber pads to the left hand side of the UPS and Extended Battery Module. This will become the bottom of the UPS. 9 2. Rotate the UPS and Extended Battery Module 90 degrees to stand as a tower. Install dust covers on each module and secure the tie plate between the UPS and Extended Battery Module using four M5X7L flat head screws. Optionally adhere four circular rubber pads to each rack mount ear to use as tower stands and screw to the bottom of the UPS and EBM using four M5X6L pan head screws for added stability. 1 2 10 11 12 13 14 15 16 17 18 19 20 21 22 23 3. Remove the front bezel of the LCD screen. 4. Rotate the LCD screen 90 degrees clockwise. Note: Follow the Extended Battery Module (EBM) unpacking instructions label found on 5. Replace the front bezel of the LCD screen. top of the EBM box. 3 4 5 ITEM CONTENT QTY ITEM CONTENT QTY 1 Power module 1 12 Quick Start Guide 1 2 Extended Battery Module (EBM) 3 Rackmount left rail 4 Rackmount right rail 5 Left hanging bracket 6 Right hanging bracket 7 Phone line 1 13 Safety instruction 1 2 14 Registration warranty card 1 2 15 PowerPanel Management Software Download Card 1 2 16 Rackmount ears 4 2 17 Tie plate 1 1 18 Flat head screws M5X7L 16 8 USB communication cable 1 19 Pan head screws M5X12L 24 9 Input / Output terminal block cover (Only for OL8KRT and OL10KRT models) 1 20 Pan head screws M5X6L 12 10 Serial Interface Cable (RS-232) 21 Plastic washers 16 1 22 Screw hole dust covers 28 11 NEMA L6-30P to IEC-320-C13 power cord 1 23 Rubber pads 24 Need Additional Help? Feel free to contact our Tech Support department with installation, troubleshooting, or general product questions. CyberPower Technical Support | 1-877-297-6937 | [email protected] | cyberpowersystems.com 4241 12th Avenue E, Suite 400, Shakopee, MN 55379, USA Hours of Operation: Monday - Friday, 7:00am - 6:00pm (CST) This document is believed to be accurate, but CyberPower reserves the right to change or correct the contents and does not assume any responsibility for omissions or errors. Entire contents copyright © 2017 CyberPower Systems, Inc. All rights reserved. Reproduction in whole or in part without permission is prohibited. K01-0000648-00 UPS INPUT/OUTPUT ELECTRICAL CONNECTION IMPORTANT! Make sure the utility circuit breaker feeding the UPS input is in the OFF position IMPORTANT! Verify the input branch circuit breaker and wiring meet the recommended sizing: UPS CAPACITY 6KVA 8KVA 10KVA BRANCH CIRCUIT BREAKER 40A 50A 70A WIRING AWG 10 AWG 8 AWG 6 AWG WIRING MM2 5.5 MM2 8.0 MM2 14.0 MM2 Note: For UPS installations requiring back feed protection please refer to the User Manual available to download on www.cyberpowersystems.com. OL6KRT ELECTRICAL CONNECTION: Connect the L6-30P input power cord to a properly wired L6-30R outlet. Proceed to connect Extended Battery Module directions. OL8KRT AND OL10KRT ELECTRICAL CONNECTION: Please see the instructions as shown below. 1. Separate the top and bottom covers by loosening the two screws to separate the top and bottom covers. 2. Fix the bottom cover on the terminal block by tightening the two screws to fix the bottom cover on the terminal block. 3. Insert the input cable through the appropriate cable gland (not included). 4. Connect the three wires to the input terminal block. 1 2 3 4 5. Insert the output cable through the appropriate cable gland (not included). 6. Connect the three wires to the output terminal block. 7. Fix the top cover on the bottom cover by tightening the four screws to fix the top cover on the bottom cover. 5 6 7 CONNECTING EXTENDED BATTERY MODULE TO UPS POWER MODULE 1. Make sure the Extended Battery Module (EBM) DC breaker is in the OFF position. 2. Remove the DC power input protective cover on the UPS. 3. Connect the Extended Battery Module connector to the UPS. Ensure it is seated properly (connector will click into place). Secure the connector to the UPS by rotating the protective cover over the EBM connector and screw it on to the UPS. 1 2 3 OFF POWER ON THE UPS SYSTEM 1. Switch EBM DC breaker to the ON position. 1 2. Switch the utility circuit breaker feeding the UPS to the ON position. 3. Turn the UPS ON - push and hold the ON/OFF power button for 3 seconds; you will hear continuous beeps, the BATTERY ON yellow LED will first turn on for a couple of seconds followed by the ON-LINE green LED. 4. Customize UPS system configuration settings as needed. See User's Manual for complete details. User Manual is available to download on www.cyberpowersystems.com. 5. Connect equipment load to the UPS system. 2 ON 3

  • 1

Need Additional Help? Feel free to contact our Tech Support department with installation,
troubleshooting, or general product questions.
CyberPower Technical Support | 1-877-297-6937 | [email protected] | cyberpowersystems.com
4241 12th Avenue E, Suite 400, Shakopee, MN 55379, USA
Hours of Operation: Monday – Friday, 7:00am – 6:00pm (CST)
This document is believed to be accurate, but CyberPower reserves the right to change or correct the contents and does not
assume any responsibility for omissions or errors. Entire contents copyright © 2017 CyberPower Systems, Inc. All rights reserved.
Reproduction in whole or in part without permission is prohibited.
5. Insert the output cable through the appropriate cable gland (not included).
6. Connect the three wires to the output terminal block.
7. Fix the top cover on the bottom cover by tightening the four screws to fix the top
cover on the bottom cover.
1.
Make sure the Extended Battery Module (EBM) DC breaker is in the OFF position.
2. Remove the DC power input protective cover on the UPS.
3. Connect the Extended Battery Module connector to the UPS. Ensure it is seated
properly (connector will click into place). Secure the connector to the UPS by
rotating the protective cover over the EBM connector and screw it on to the UPS.
1.
Separate the top and bottom covers by loosening the two screws to separate the top
and bottom covers.
2. Fix the bottom cover on the terminal block by tightening the two screws to fix the
bottom cover on the terminal block.
3. Insert the input cable through the appropriate cable gland (not included).
4. Connect the three wires to the input terminal block.
1.
Switch EBM DC breaker to the ON position.
2. Switch the utility circuit breaker feeding
the UPS to the ON position.
3. Turn the UPS ON – push and hold the ON/OFF
power button for 3 seconds; you will hear
continuous beeps, the BATTERY ON yellow
LED will first turn on for a couple of seconds
followed by the ON-LINE green LED.
4. Customize UPS system configuration settings
as needed. See User’s Manual for complete details.
User Manual is available to download on
www.cyberpowersystems.com.
5. Connect equipment load to the UPS system.
1.
Install rack mount ears using eight M5X7L flat head screws and hanging brackets using
six M5X6L pan head screws.
2. Locate space where the UPS will be installed in the rack.
3. Install rack mount rails using eight M5X6L pan head screws with plastic washers and
adjust rails to necessary rack depth.
4. Place and secure the UPS on to the rack mount rails using four M5X12L pan head screws.









OL6KRT/OL8KRT/OL10KRT/
QUICK START GUIDE
K01-0000648-00
UNPACKING
RACKMOUNT INSTALLATION
TOWER INSTALLATION
UPS INPUT/OUTPUT ELECTRICAL CONNECTION
UPS INPUT/OUTPUT ELECTRICAL CONNECTION
CONNECTING EXTENDED BATTERY
MODULE TO UPS POWER MODULE
POWER ON THE UPS SYSTEM
ITEM
CONTENT
QTY
1
Power module
1
2
Extended Battery Module (EBM)
1
3
Rackmount left rail
2
4
Rackmount right rail
2
5
Left hanging bracket
2
6
Right hanging bracket
2
7
Phone line
1
8
USB communication cable
1
9
Input / Output terminal block cover
(Only for OL8KRT and OL10KRT models)
1
10
Serial Interface Cable
(RS-232)
1
11
NEMA L6-30P to
IEC-320-C13 power cord
1
1
3
6
2
4
5
1.
Adhere eight circular rubber pads to the left hand side of the UPS and Extended
Battery Module. This will become the bottom of the UPS.
2. Rotate the UPS and Extended Battery Module 90 degrees to stand as a tower. Install
dust covers on each module and secure the tie plate between the UPS and Extended
Battery Module using four M5X7L flat head screws. Optionally adhere four circular
rubber pads to each rack mount ear to use as tower stands and screw to the bottom
of the UPS and EBM using four M5X6L pan head screws for added stability.
3. Remove the front bezel of the LCD screen.
4. Rotate the LCD screen 90 degrees clockwise.
5. Replace the front bezel of the LCD screen.
12
13
14
15
16
17
18
19
20
21
23
1
2
3
1
 
 
 
 
 
 
3
4
3
4
5
Note:
Follow the Extended Battery Module (EBM) unpacking instructions label found on
top of the EBM box.
1
1
5
2
3
6
7
4
1
2
3
4
5
6
7
8
9
2U
3U
4U
1U
Rack mount ear
Rack mount rail
2
Note:
Repeat these steps with the Extended Battery Module.
Note:
For UPS installations requiring back feed protection please refer to the User
Manual available to download on www.cyberpowersystems.com.
UPS CAPACITY
BRANCH CIRCUIT BREAKER
WIRING AWG
WIRING MM
2
6KVA
40A
10 AWG
5.5 MM
2
8KVA
50A
8 AWG
8.0 MM
2
10KVA
70A
6 AWG
14.0 MM
2
IMPORTANT!
Make sure the utility circuit breaker feeding the UPS input is in the OFF position
IMPORTANT!
Verify the input branch circuit breaker and wiring meet the recommended sizing:
3
8
9
10
11
22
1
2
OFF
ON
2
7


 
 


OL6KRT ELECTRICAL CONNECTION:
Connect the L6-30P input power cord to a properly wired
L6-30R outlet. Proceed to connect Extended Battery Module directions.
OL8KRT AND OL10KRT ELECTRICAL CONNECTION:
Please see the instructions as shown below.
ITEM
CONTENT
QTY
12
Quick Start Guide
1
13
Safety instruction
1
14
Registration warranty card
1
15
PowerPanel Management
Software Download Card
1
16
Rackmount ears
4
17
Tie plate
1
18
Flat head screws M5X7L
16
19
Pan head screws M5X12L
24
20
Pan head screws M5X6L
12
21
Plastic washers
16
22
Screw hole dust covers
28
23
Rubber pads
24