D-Link 301P Manual - Page 12
Power ON Self-Test - dp +
UPC - 790069262579
View all D-Link 301P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
Power ON Self-Test Every DP-301P+ has been factory-tested to operate properly. When the DP-301P+ is powered ON, it also automatically performs a Self-Test on each of its major components. The final result of the Self-Test is signaled by the state of the LPT LED indicator following the Self-Test. Preliminary to the actual component tests, the three LED indicators are tested to confirm their steady and flashing operation. Immediately after power-up, all three of the green LEDs should illuminate steadily for several seconds. Then the LPT LED should light OFF. Irregularity of any of the three LEDs during these LED tests may mean there is a problem with the LEDs themselves. The actual component tests immediately follow the LED tests. A normal (no fault) result is signaled by a simultaneous flashing of the LPT LED three times, followed by a quiescent state with the LPT LED dark. If the Self-Test routine traps any component error, then following the LED tests the Self-Test will halt and the LPT LED will continuously signal the error according to the following table. In the event of any such error signal, contact your dealer for correction of the faulty unit. LPT LED Faulty Component On 1 long 3 short 1 long 5 short 1 long 6 short 1 long 8 short DRAM error Flash Protected Flash Erase/Program error LAN Controller error LPT Controller error 8