DCS-4605EV Vigilance 5 Megapixel H.265 Outdoor Dome Camera System Requirements for Web Interface D-ViewCam™ System Requirements D-ViewCam™ Software Functions General Weight Power Power Consumption Temperature Humidity Certifications Dimensions • Operating System: Microsoft Windows 10 / 8 / 7 • Operating System: • 32-bit: Windows 8 / 7 (SP1) • 64-bit: Windows 10 / 8 / 7 (SP1) / Server 2012 / Server 2008 R2 • Remote management/control of up to 32 cameras • Supports all management functions provided in web interface • Browser: Internet Explorer, Firefox, Chrome • Web Browser: Internet Explorer 7 or higher • Protocol: Standard TCP/IP • Viewing of up to 32 cameras on one screen • Scheduled motion triggered, or manual recording options • 365 g ± 5% • Input: 100 to 240 V AC, 50/60 Hz • 6 W ± 5% (PoE) • Operating: -30 to 50 °C (-22 to 124 °F) • Operating: 20% to 80% non-condensing • CE • CE LVD • Output: 12 V DC 1.5 A • Storage: -20 to 70 °C (-4 to 158 °F) • Storage: 5% to 95% non-condensing • FCC • RCM Warranty Part Number • 5-Year Limited Warranty3

  • 1
  • 2
  • 3
  • 4

DCS-4605EV
Vigilance 5 Megapixel H.265 Outdoor Dome Camera
System Requirements for Web
Interface
• Operating System: Microsoft Windows 10 / 8 / 7
• Browser: Internet Explorer, Firefox, Chrome
D-ViewCam™ System Requirements
• Operating System:
• 32-bit: Windows 8 / 7 (SP1)
• 64-bit: Windows 10 / 8 / 7 (SP1) / Server 2012 / Server
2008 R2
• Web Browser: Internet Explorer 7 or higher
• Protocol: Standard TCP/IP
D-ViewCam™ Software Functions
• Remote management/control of up to 32 cameras
• Supports all management functions provided in web
interface
• Viewing of up to 32 cameras on one screen
• Scheduled motion triggered, or manual recording
options
General
Weight
• 365 g ± 5%
Power
• Input: 100 to 240 V AC, 50/60 Hz
• Output: 12 V DC 1.5 A
Power Consumption
• 6 W ± 5% (PoE)
Temperature
• Operating: -30 to 50 °C (-22 to 124 °F)
• Storage: -20 to 70 °C (-4 to 158 °F)
Humidity
• Operating: 20% to 80% non-condensing
• Storage: 5% to 95% non-condensing
Certifications
• CE
• CE LVD
• FCC
• RCM
Dimensions
Warranty
Part Number
• 5-Year Limited Warranty