Topology A Fast Ethernet workgroup is configured in a star topology and is built around a maximum of two repeaters. Each workgroup forms a separate LAN (also known as a segment or collision domain), and these workgroups can be easily interconnected through switches, bridges, or routers to form one LAN large enough to encompass a high-rise building or campus environment. Recent innovations in LAN hub technology such as stackable hubs, coupled with the decreasing cost of switches, bridges, and routers, allow the design of low-cost, efficient Fast Ethernet workgroups and enterprise LANs. The following factors strongly influence the architecture of Fast Ethernet networks: • The EIA/TIA 568 Wiring Standard imposes a 100 meter limit on horizontal runs of twisted-pair cables; that is, connections from the wiring closet to the end-station. • Fast Ethernet's increased operational speed reduces the maximum distance between all elements of the LAN (see below). • The EIA/TIA 568 Wiring Standard does not support the use of coaxial cables for horizontal wiring. Network Diameter Network diameter, which is the distance between two end-stations in the same collision domain, is the primary difference between traditional Ethernet and Fast Ethernet. Due to the increased speed in Fast Ethernet and adherence to the EIA/TIA 568 wiring rules, the network diameter of a Fast Ethernet collision domain is limited to 205 meters; in contrast, the maximum 10BASE-T Ethernet collision domain diameter can be up to 500 meters. 6 Introduction

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

Introduction
6
Topology
A Fast Ethernet workgroup is configured in a star topology and is built
around a maximum of two repeaters.
Each workgroup forms a separate
LAN (also known as a segment or collision domain), and these workgroups
can be easily interconnected through switches, bridges, or routers to form
one LAN large enough to encompass a high-rise building or campus envi-
ronment.
Recent innovations in LAN hub technology such as stackable
hubs, coupled with the decreasing cost of switches, bridges, and routers,
allow the design of low-cost, efficient Fast Ethernet workgroups and enter-
prise LANs.
The following factors strongly influence the architecture of Fast Ethernet
networks:
The EIA/TIA 568 Wiring Standard imposes a 100 meter limit on
horizontal runs of twisted-pair cables; that is, connections from the
wiring closet to the end-station.
Fast Ethernet’s increased operational speed reduces the maximum
distance between all elements of the LAN (see below).
The EIA/TIA 568 Wiring Standard does not support the use of co-
axial cables for horizontal wiring.
Network Diameter
Network diameter, which is the distance between two end-stations in the
same collision domain, is the primary difference between traditional
Ethernet and Fast Ethernet.
Due to the increased speed in Fast Ethernet and
adherence to the EIA/TIA 568 wiring rules, the network diameter of a Fast
Ethernet collision domain is limited to 205 meters; in contrast, the maxi-
mum 10BASE-T Ethernet collision domain diameter can be up to 500
meters.