D-Link DGS-108 Product Manual - Page 11

booted. So, from the time power is first applied to the Switch, about 17 seconds is required before - b 8 port

Page 11 highlights

D-Link DGS-108 Unmanaged Gigabit Ethernet Switch The Cable Diagnostic function operates only during the Switch boot up (when the Switch is first powered on). The Cable Diagnostic first scans the eight Ethernet ports to determine if the Ethernet cable is in good working order. This process is indicated by the Speed LED blinking green for each of the eight ports, sequentially. The initial port scan takes about 10 seconds. If a cable fault is detected, it is indicated by the corresponding port's Speed LED glowing amber for 5 seconds, after the initial port scan. The Switch is then reset for normal operation. It takes about 2 seconds for the Switch to reset. The entire Cable Diagnostic process takes about 17 seconds from the time the Switch is booted. So, from the time power is first applied to the Switch, about 17 seconds is required before the Switch will begin normal operation. Note: There is no display of cable faults detected by the Cable Diagnostic during the normal operation of the Switch, only when the Switch is booted up or power-cycled. NOTE: The Cable Diagnostic function does not support 10M/100M. If the port is connected to a 10M/100M device, see the Link LED to check if the cable is good or not. 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29

D-Link DGS-108 Unmanaged Gigabit Ethernet Switch
4
The Cable Diagnostic function operates only during the Switch boot up (when the Switch is first
powered on).
The Cable Diagnostic first scans the eight Ethernet ports to determine if the Ethernet cable is in
good working order. This process is indicated by the
Speed
LED blinking green for each of the
eight ports, sequentially. The initial port scan takes about 10 seconds. If a cable fault is detected, it
is indicated by the corresponding port’s
Speed
LED glowing amber for 5 seconds, after the initial
port scan. The Switch is then reset for normal operation. It takes about 2 seconds for the Switch to
reset. The entire Cable Diagnostic process takes about 17 seconds from the time the Switch is
booted. So, from the time power is first applied to the Switch, about 17 seconds is required before
the Switch will begin normal operation.
Note: There is no display of cable faults detected by the Cable Diagnostic during the normal
operation of the Switch, only when the Switch is booted up or power-cycled.
NOTE:
The Cable Diagnostic function does not support 10M/100M. If the port is
connected to a 10M/100M device, see the Link LED to check if the cable is good
or not.