D-Link DGS-3630-28SC WEB Reference Guide - Page 128

show poe pd alive

Page 128 highlights

DGS-3630 Layer 3 Stackable Managed Switch CLI Reference Guide Display Parameters Unit Delivered Power budget Usage-Threshold Preempt Trap State The unit ID of stacking device. The actual amount of power delivered to the PD in watts. The total power can be provided by the device in watts. The utilization threshold to record a log. Enabled: The power management mode is policy preempt, high priority PD can preempt the provided power of lower priority PD. Disabled: The power management mode is first in first serviced. Enabled: The trap is sent when the PoE usage threshold exceeds the specified value. Disabled: The trap is not sent when the PoE usage threshold exceeds the specified value. Example This example shows how to display the PoE detailed parameters for unit 1. Switch#show poe power module unit 1 detail Unit Delivered(W) Power Budget(W) Usage-Threshold(%) Preempt Trap State 1 0 370 50 Enabled Enabled PoE system parameters: Unit Max Ports Device ID 1 24 E121 SW Version ---------20 Switch# Display Parameters Max ports Device ID S/W version The maximum port number of the PoE sub-system. The hardware version of the PoE chip. The firmware version of the PoE chip. 15-4 show poe pd alive This command is used to display the PD alive check settings. show poe pd alive [interface INTERFACE-ID [, | -]] Parameters interface INTERFACE-ID , - (Optional) Specifies the interfaces to be displayed. (Optional) Specifies a series of interfaces or separate a range of interfaces from a previous range. No space is allowed before and after the comma. (Optional) Specifies a range of interfaces. No space is allowed before and after the hyphen. 126

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187

DGS-3630 Layer 3 Stackable Managed Switch CLI Reference Guide
126
Display Parameters
Unit
The unit ID of stacking device.
Delivered
The actual amount of power delivered to the PD in watts.
Power budget
The total power can be provided by the device in watts.
Usage-Threshold
The utilization threshold to record a log.
Preempt
Enabled:
The power management mode is policy preempt, high priority
PD can preempt the provided power of lower priority PD.
Disabled:
The power management mode is first in first serviced.
Trap State
Enabled:
The trap is sent when the PoE usage threshold exceeds the
specified value.
Disabled:
The trap is not sent when the PoE usage threshold exceeds the
specified value.
Example
This example shows how to display the PoE detailed parameters for unit 1.
Switch#show poe power module unit 1 detail
Unit Delivered(W)
Power Budget(W)
Usage-Threshold(%)
Preempt
Trap State
---------------------------------------------------------------------------
1
0
370
50
Enabled
Enabled
PoE system parameters:
Unit
Max Ports
Device ID
SW Version
----
---------
---------
----------
1
24
E121
20
Switch#
Display Parameters
Max ports
The maximum port number of the PoE sub-system.
Device ID
The hardware version of the PoE chip.
S/W version
The firmware version of the PoE chip.
15-4
show poe pd alive
This command is used to display the PD alive check settings.
show poe pd alive [interface
INTERFACE-ID
[, | -]]
Parameters
interface
INTERFACE-ID
(Optional) Specifies the interfaces to be displayed.
,
(Optional) Specifies a series of interfaces or separate a range of interfaces from
a previous range. No space is allowed before and after the comma.
-
(Optional) Specifies a range of interfaces. No space is allowed before and after