D-Link DSN-3400-10 Datasheet - Page 4

Volume & RAID Support, Storage Management, Power, Environmental, Physical, International - 104

Page 4 highlights

DSN-3000 Series iSCSI SAN Array Volume & RAID Support RAID Controller RAID Support Volumes Target Nodes Online Capacity Expansion Hot Swappable Drives Instant Volume Access Free Space Defragmentation Auto-Detection Failed Drive Auto-Rebuild Spare Drive RAID Level Migration Drive Roaming in Power Off (configured drives are not bay-specific) Micro Rebuilds Storage Management Embedded IP-Based Management GUI Firmware Field Upgradeable SMI-S Version 1.1 Power Supply Type Input Voltage Input Frequency Input Current Power Factor Correction Power Consumption Thermal Environmental Operating Temperature Storage Temperature Operating Humidity Storage Humidity Physical (approximate) Form Factor Dimensions (W x D x H) Weight International Approvals Emissions Safety • Single- Integrated in ASIC • RAID Levels 0, 1, 1+0 and 5 (Striped sets, mirrored sets, striped mirrored sets and parity sets) • 1,024 Virtual Volumes (256 accessible per initiator) • 1,024 • Yes • Yes • Yes • Yes • Yes • Yes • Yes • Yes • Yes • Create, manage, expand and monitor storage pool, volumes and RAID. • Event manager to view and persist events. • Yes • Yes • Triple Redundant 3U 760 Watt • 90-264 VAC (auto-switching) • 47-63 Hz • 20A Maximum at 90VAC and 10A Maximum at 264VAC (maximum amps vs. voltage varies linearly throughout this voltage range) • 95%@110V, Full load • 570W (full configuration) • 2000 BTU / hour (full configuration) • 32° to 104°F (0° to 40°C) • -4° to 158°F (-20° to 70°C) • 20% ~ 90% (Non-condensing) • 10% ~ 95% (Non-condensing) • 3U industry-standard 19-inch rack • 17.2in x 22.5in x 5.2in (438mm x 571mm x 133mm) • 72.8 pounds / 33 kilograms (full configuration) • CE Class A, FCC Class A, C-Tick Class A, VCCI Class A • CSA 60950-1, UL60950-1, IEC 60950-1, EN 60950-1 business

  • 1
  • 2
  • 3
  • 4
  • 5

business
DSN-3000
Series iSCSI SAN Array
Volume & RAID Support
RAID Controller
Single- Integrated in ASIC
RAID Support
RAID Levels 0, 1, 1+0 and 5 (Striped sets, mirrored sets, striped mirrored sets and parity sets)
Volumes
1,024 Virtual Volumes (256 accessible per initiator)
Target Nodes
1,024
Online Capacity Expansion
Yes
Hot Swappable Drives
Yes
Instant Volume Access
Yes
Free Space Defragmentation
Yes
Auto-Detection Failed Drive
Yes
Auto-Rebuild Spare Drive
Yes
RAID Level Migration
Yes
Drive Roaming in Power Off
(configured drives are not
bay-specific)
Yes
Micro Rebuilds
Yes
Storage Management
Embedded IP-Based Management
GUI
Create, manage, expand and monitor storage pool, volumes and RAID.
Event manager to view and persist events.
Firmware Field Upgradeable
Yes
SMI-S Version 1.1
Yes
Power
Supply Type
Triple Redundant 3U 760 Watt
Input Voltage
90-264 VAC (auto-switching)
Input Frequency
47-63 Hz
Input Current
20A Maximum at 90VAC and 10A Maximum at 264VAC
(maximum amps vs. voltage varies linearly throughout this voltage range)
Power Factor Correction
95%@110V, Full load
Power Consumption
570W (full configuration)
Thermal
2000 BTU / hour (full configuration)
Environmental
Operating Temperature
32° to 104°F (0° to 40°C)
Storage Temperature
-4° to 158°F (-20° to 70°C)
Operating Humidity
20% ~ 90% (Non-condensing)
Storage Humidity
10% ~ 95% (Non-condensing)
Physical
(approximate)
Form Factor
3U industry-standard 19-inch rack
Dimensions (W x D x H)
17.2in x 22.5in x 5.2in (438mm x 571mm x 133mm)
Weight
72.8 pounds / 33 kilograms (full configuration)
International Approvals
Emissions
CE Class A, FCC Class A, C-Tick Class A, VCCI Class A
Safety
CSA 60950-1, UL60950-1, IEC 60950-1, EN 60950-1