D-Link DSN-4200 Datasheet - Page 4

Volume & RAID Support, Storage Management, Power

Page 4 highlights

DSN-4000 Series iSCSI SAN Array Access Control of Management iSCSI/TCP/IP Full HW Offload Jumbo Frames Support LAG Support (Link Aggregation) Flow Control Volume & RAID Support RAID Controller RAID Support Volumes Target Nodes Online Capacity Expansion Hot Swappable Drives Instant Volume Access Free Space Defragmentation Auto-Detection Failed Drive Auto-Rebuild Spare Drive RAID Level Migration Drive Roaming in Power Off (configured drives are not bay-specific) Micro Rebuilds Storage Management Embedded IP-Based Management GUI Firmware Field Upgradeable SMI-S Version 1.1 Event Log Power Supply Type Input Voltage: Input Frequency: Current Power Factor Correction • Yes • Yes • Yes • Up to four LAGs (Static LAG) • Enabled by default • Up to eight LAGs (Static LAG) • Integrated in ASIC chip • RAID Levels 0, 1, 1+0 and 5 (Striped sets, mirrored sets, striped mirrored sets and parity sets) • 1,024 Virtual Volumes (256 accessible per initiator) • 1,024 • Yes • Yes • Yes • Yes • Yes • Yes • Yes • Yes • Yes • Create, manage, expand and monitor storage pool, volumes and RAID • Event manager to view and persist events • Yes • Yes • Yes • Dual Redundant Hot-Swappable 450 Watt • 90-264 VAC • 47-63 Hz • 7 to 8A (100V); 3.5 to 4A(240V) • PFC 80PLUS

  • 1
  • 2
  • 3
  • 4
  • 5

DSN-4000 Series
iSCSI SAN Array
Access Control of Management
• Yes
iSCSI/TCP/IP Full HW Offload
• Yes
Jumbo Frames Support
• Yes
LAG Support (Link Aggregation)
Up to four LAGs (Static LAG)
Up to eight LAGs (Static LAG)
Flow Control
• Enabled by default
Volume & RAID Support
RAID Controller
• Integrated in ASIC chip
RAID Support
RAID Levels 0, 1, 1+0 and 5 (Striped sets, mirrored sets, striped mirrored sets and parity sets)
Volumes
1,024 Virtual Volumes (256 accessible per initiator)
Target Nodes
• 1,024
Online Capacity Expansion
• Yes
Hot Swappable Drives
• Yes
Instant Volume Access
• Yes
Free Space Defragmentation
• Yes
Auto-Detection Failed Drive
• Yes
Auto-Rebuild Spare Drive
• Yes
RAID Level Migration
• Yes
Drive Roaming in Power Off
(configured drives are not bay-specific)
• Yes
Micro Rebuilds
• Yes
Storage Management
Embedded IP-Based Management GUI
Create, manage, expand and monitor storage pool, volumes and RAID
Event manager to view and persist events
Firmware Field Upgradeable
• Yes
SMI-S Version 1.1
• Yes
Event Log
• Yes
Power
Supply Type
Dual Redundant Hot-Swappable 450 Watt
Input Voltage:
• 90-264 VAC
Input Frequency:
• 47-63 Hz
Current
7 to 8A (100V); 3.5 to 4A(240V)
Power Factor Correction
• PFC 80PLUS