Technician Bulletin Issue 17 2010 - 10.25.10 Diagnostic Code 14-xxx Internal Storage Error Detected. 15-xxx Internal Storage Error Detected. 16-xxx MRV Failure 21-xxx Internal Storage Error Detected. 40-xxx ODU Alignment Problem/Signal Distribution Problem 41-xxx ODU Alignment Problem/Signal Distribution Problem 42-xxxODU Alignment Problem/Signal Distribution Problem 43-xxx ODU Alignment Problem/Signal Distribution Problem 44-xxx Second Tuner Connection Problem Issue A problem was detected reading your internal storage device. This may be a simple initialization error or a critical fault. Please reboot the box now. That may fix the problem. A problem was detected reading your internal storage device. This may be a simple initialization error or a critical fault. (HR24 / H24 only) This error indicates a failure of the internal MRV hardware. A problem was detected reading your internal storage device. This may be a simple initialization error or a critical fault. Non-SWiM. Fails basic +13/+18 ODU test for signal. SWiM only, tuners locked but missing guide data. Non-SWiM, tuners locked but missing guide data. Signal levels more than 5 points below IV levels. This can be level issue with tuner 1, tuner 2 or both tuners. Your receiver might be incorrectly configured or incorrectly connected to tuner 2. This is an IV test similar to the test for error 43. Resolution / Troubleshooting Attempt reboot but replace if problem continues. Diagnostic code 15 indicates the drive is accessible but does not pass integrity tests. Replace the receiver. Replace the receiver. Attempt reboot but replace if problem continues. Verify all satellite positions that the receiver is supporting using the signal meter screen to verify transponder signal levels. Check for BBC‟s on non-SWM installs connected to the Hx and HRxx products. Verify cabling from the ODU to the STB. Check for crimped or frayed cables, splitters, barrels and wall plates that may need replacement. Use a Super Buddy or an AIM meter to verify: (Signal) Power levels- -approx. -30‟s to -40‟s dbm ES/NO (AIM) C/N (Super Buddy) - greater than 10dB for KA/KU ES/NO (AIM) C/N (Super Buddy) - greater than 10db for KA/KU. If levels are below spec, check the alignment of the ODU. If non-SWiM ODU, verify 2 cables are present and connected. If present, follow troubleshooting steps for diagnostic codes 40, 41, 42, 43. If not present, correct or go to the system setup and set the box for single tuner. Note that an IV waiver may be required. The information contained on this page is confidential, proprietary DIRECTV business information and is intended for authorized users only. 2 Unauthorized use, disclosure or copying of this information is strictly prohibited and may be unlawful.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

Technician Bulletin
The information contained on this page is confidential, proprietary DIRECTV business information and is intended for authorized users only.
Unauthorized use, disclosure or copying of this information is strictly prohibited and may be unlawful.
2
Issue 17 2010
10.25.10
Diagnostic
Code
Issue
Resolution / Troubleshooting
14-xxx Internal
Storage Error
Detected.
A problem was detected
reading your internal storage
device. This may be a simple
initialization error or a critical
fault. Please reboot the box
now. That may fix the problem.
Attempt reboot but replace if problem continues.
15-xxx Internal
Storage Error
Detected.
A problem was detected
reading your internal storage
device. This may be a simple
initialization error or a critical
fault.
Diagnostic code 15 indicates the drive is accessible but does not
pass integrity tests. Replace the receiver.
16-xxx MRV
Failure
(HR24 / H24 only) This error
indicates a failure of the
internal MRV hardware.
Replace the receiver.
21-xxx Internal
Storage Error
Detected.
A problem was detected
reading your internal storage
device. This may be a simple
initialization error or a critical
fault.
Attempt reboot but replace if problem continues.
40-xxx ODU
Alignment
Problem/Signal
Distribution
Problem
Non-SWiM. Fails basic
+13/+18 ODU test for signal.
Verify all satellite positions that the receiver is supporting using
the signal meter screen to verify transponder signal levels.
Check for BBC‟s on non
-SWM installs connected to the Hx and
HRxx products. Verify cabling from the ODU to the STB. Check
for crimped or frayed cables, splitters, barrels and wall plates that
may need replacement. Use a Super Buddy or an AIM meter to
verify: (Signal) Power levels- -approx. -
30‟s to
-
40‟s dbm ES/NO
(AIM) C/N (Super Buddy) - greater than 10dB for KA/KU ES/NO
(AIM) C/N (Super Buddy) - greater than 10db for KA/KU. If levels
are below spec, check the alignment of the ODU.
41-xxx ODU
Alignment
Problem/Signal
Distribution
Problem
SWiM only, tuners locked but
missing guide data.
42-xxxODU
Alignment
Problem/Signal
Distribution
Problem
Non-SWiM, tuners locked but
missing guide data.
43-xxx ODU
Alignment
Problem/Signal
Distribution
Problem
Signal levels more than 5
points below IV levels. This
can be level issue with tuner 1,
tuner 2 or both tuners.
44-xxx Second
Tuner
Connection
Problem
Your receiver might be
incorrectly configured or
incorrectly connected to tuner
2. This is an IV test similar to
the test for error 43.
If non-SWiM ODU, verify 2 cables are present and connected. If
present, follow troubleshooting steps for diagnostic codes 40, 41,
42, 43. If not present, correct or go to the system setup and set
the box for single tuner. Note that an IV waiver may be required.