Document # PG04-006 DCT305, DCT365 30" and 36" Wide, Distinctive Series Drop-in Gas Cooktops Revised 08/19/11 Page 2/4 PLANNING GUIDE Electrical Requirements WARNING To prevent an electric shock hazard, the power supply must meet the specifications stated below. It is the owner's responsibility to make sure that the electrical service meets electrical requirements and that the electrical outlet has been properly installed by a licensed electrician. ◊ The cooktop is supplied with a factory installed, 42 inch power cord with a, three-prong, grounding electrical plug. It is connected to the chassis at the bottom right rear corner (see Chassis Bottom Diagram below). It must be connected to a dedicated, grounded three-prong electrical outlet installed by a licensed electrician. ◊ The electrical installation, including minimum supply wire size and grounding, must be done in accordance with National Electric Code ANSI/NFPA 70* and local codes and ordinances. A copy of this standard may be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101 ◊ The correct voltage, frequency and amperage must be supplied to the electrical outlet according to the product data label located on the bottom of the chassis. See the Gas and Electrical Requirements table on this page for reference. ◊ Be certain to locate the electrical outlet so that the power may be easily disconnected if the unit needs service. Front of unit Product data label Chassis Bottom Diagram Gas Supply Requirements ◊ Be certain that the cooktop being installed is correct for the gas service being provided (natural gas or LP gas). Also, if operating the cooktop at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude operation. ◊ Units equipped for LP operation have "LP" in the model number listed on the product data label. See the Chassis Bottom Diagram for label location. ◊ Units equipped for high altitude operation have an "H" at the end of the model number listed on the product data label. ◊ Check your local building codes for the proper method of installation. In the absence of local codes, this appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54. ◊ An external manual shut-off valve must be installed between the gas inlet and the cooktop for the purpose of turning on or shutting off gas to the appliance. ◊ The cooktop comes from the factory with a regulator in the shipping carton. Use only the regulator provided. The regulator must be installed in the gas line that runs from the cooktop gas inlet to the gas shut off valve. ◊ The regulator inlet accommodates a 3/4" gas line. The inlet to the cooktop itself is equipped with a 3/4" male NPT fitting. The cooktop gas connection is located on the bottom of the cootktop in the back right corner as you face the front of the unit. See the Chassis Bottom Diagram on this page. DCT304_NG DCT365_NG DCT304_LP DCT365_LP Gas type Natural LP gas Manifold pressure 5" water column 10" water column Min. gas supply Pressure** 6" water column 11" water column Max. gas supply pressure 1/2 psi 1/2 psi Total connected load 0.25 Amp. (30 Watts) 0.25 Amp. (30 Watts) Circuit requirement 120 Vac, 60 Hz, 15 Amp. 120 Vac, 60 Hz, 15 Amp. Gas and Electrical Requirements* * The electrical and gas data on this page is for reference only. If the above data does not agree with the product data label, use the data on the product data label. ** The gas supply pressure for testing the regulator setting shall be at least 1 inch water column (249 Pa) above the specified manifold pressure. Specifications subject to change without notice. www.dacor.com Phone: (800) 7943-.010993

  • 1
  • 2
  • 3
  • 4

PLANNING
GUIDE
Specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
Electrical Requirements
WARNING
To prevent an electric shock hazard, the power supply must meet
the specifications stated below. It is the owner’s responsibility
to make sure that the electrical service meets electrical require-
ments and that the electrical outlet has been properly installed by
a licensed electrician.
The cooktop is supplied with a factory installed, 42 inch power cord
with a, three-prong, grounding electrical plug. It is connected to
the chassis at the bottom right rear corner (see
Chassis Bottom
Diagram
below).
It must be connected to a dedicated, grounded
three-prong electrical outlet installed by a licensed electrician.
The electrical installation, including minimum supply wire size and
grounding, must be done in accordance with National Electric Code
ANSI/NFPA 70* and local codes and ordinances. A copy of this
standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The correct voltage, frequency and amperage must be supplied to
the electrical outlet according to the product data label located on the
bottom of the chassis. See the Gas and Electrical Requirements table
on this page for reference.
Be certain to locate the electrical outlet so that the power may be
easily disconnected if the unit needs service.
Gas Supply Requirements
Be certain that the cooktop being installed is correct for the gas
service being provided (natural gas or LP gas). Also, if operating
the cooktop at an altitude above 4000 ft. (1219 m) make sure it is
equipped for high altitude operation.
Units equipped for LP operation have “LP” in the model number listed
on the product data label. See the Chassis Bottom Diagram for label
location.
Units equipped for high altitude operation have an “H” at the end of
the model number listed on the product data label.
Check your local building codes for the proper method of installation.
In the absence of local codes, this appliance should be installed in
accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54.
An external manual shut-off valve must be installed between the gas
inlet and the cooktop for the purpose of turning on or shutting off gas
to the appliance.
The cooktop comes from the factory with a regulator in the shipping
carton. Use only the regulator provided. The regulator must be
installed in the gas line that runs from the cooktop gas inlet to the gas
shut off valve.
The regulator inlet accommodates a 3/4” gas line. The inlet to the
cooktop itself is equipped with a 3/4” male NPT fitting.
The cooktop gas connection is located on the bottom of the cootktop in the
back right corner as you face the front of the unit. See the
Chassis Bottom
Diagram
on this page.
DCT304_NG
DCT365_NG
DCT304_LP
DCT365_LP
Gas type
Natural
LP gas
Manifold
pressure
5” water column
10” water column
Min. gas supply
Pressure**
6” water column
11” water column
Max. gas supply
pressure
1/2 psi
1/2 psi
Total connected load
0.25 Amp.
(30 Watts)
0.25 Amp.
(30 Watts)
Circuit requirement
120 Vac,
60 Hz, 15 Amp.
120 Vac,
60 Hz, 15 Amp.
GAS AND ELECTRICAL REQUIREMENTS*
* The electrical and gas data on this page is for reference only. If the
above data does not agree with the product data label, use the data on the
product data label.
** The gas supply pressure for testing the regulator setting shall be at least
1 inch water column (249 Pa) above the specified manifold pressure.
DCT305, DCT365
CHASSIS BOTTOM DIAGRAM
Front of unit
Product data label
Document # PG04-006
Revised 08/19/11
Page 2/4
30” and 36” Wide, Distinctive Series
Drop-in Gas Cooktops