DR30D Document # PG05 - 006 Distinctive Range Revised 1/26/10 Page 2/2 PLANNING GUIDE Cabinet Layout ■■ Carefully check the location where the range is to be installed. For best performance, the range should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets. ■■ To reduce the risk of personal injury and to reduce accumulated smoke in the room, Dacor strongly recommends installing a range hood. A range hood should project horizontally a minimum of five (5) inches beyond the face of the cabinets. ■■ All maximum and minimum dimensions and clearances shown in the diagram below must be maintained for safe operation. ■■ The range may be installed flush to the rear wall. A non-combustible rear wall is not mandatory, but Dacor highly recommends installing a non-combustible material from the countertop level up to the vent hood or installation of a backguard. ■■ Any openings in the wall behind the appliance or in the floor underneath it must be sealed. Cabinet tolerances: -1/16", (+1.6mm) -0 Gas and Electrical Service ■■ The shaded area shown below denotes the location of the gas inlet and the electrical junction box/receptacle. This is the recommended location. For replacement purposes, the location of the existing utilities may be utilized provided they do not interfere with the sides or rear of the range. Check local building codes for permissible gas valve locations. ■■ An external manual shut-off valve must be installed between the gas inlet and the range for the purpose of turning on or shutting off gas to the appliance. The installation must allow for the following: ■■ Access to the gas shut-off valve when the unit is installed. ■■ Access to the remote circuit breaker panel/fuse box when the range is in place. ■■ The gas supply piping, gas shut-off valve and the electrical junction box or receptacle must be located so they do not interfere with the range when it is installed. ■■ The junction box and gas shut off valve must be located so that the range can be pulled out for service while the appliance remains connected. E 13" (33.0 cm) Max.4 18" (45.7 cm) Min.1, 4 Non-combustible surface along back wall recommended 30" (76.2 cm) Min.1 F 10" (25.4 cm) Min. to combustible side walls above the range (both sides) Note 2 37 7/8 (96.2 cm) Max. Suggested location of utilities 3 1 Vertical to combustible surface from range grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances. 2 Cabinet/countertop depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of front panel, see product dimensions. 3 Consult local code for exact location requirements. 4 Not applicable for cabinets more than a horizontal distance of 10" (25.4 cm) from the edge of the range. Required Cabinet Dimensions Cutout Dimensions E F 36" (91.4 cm)* 30" (76.2 cm)** 30 1/16" (916mm) * Recommended ** Minimum Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.Dacor.com Phone: (800) 793-0093 5.15

  • 1
  • 2

PLANNING
GUIDE
www.Dacor.com
Phone: (800) 793-0093
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
5.15
Distinctive Range
DR30D
Note 2
E
F
2
Cabinet/countertop depth is at discretion of customer but
cabinet face MUST NOT protrude further than rear of front
panel, see product dimensions.
3
Consult local code for exact location requirements.
1
Vertical to combustible surface from range grate level; if
installing an overhead vent hood, also check the hood
specifications for minimum required clearances.
Non-combustible
surface along
back wall
recommended
10” (25.4 cm) Min.
to combustible side
walls above the range
(both sides)
30” (76.2 cm)
Min.
1
37 7/8
(96.2 cm)
Max.
13” (33.0 cm)
Max.
4
18” (45.7 cm)
Min.
1, 4
Suggested
location of
utilities
3
4
Not applicable for cabinets more than a horizontal
distance of 10” (25.4 cm) from the edge of the range.
Cutout Dimensions
E
F
36” (91.4 cm)*
30” (76.2 cm)**
30
1
/
16
” (916mm)
* Recommended
** Minimum
Gas and Electrical Service
The shaded area shown below denotes the location of the gas inlet
and the electrical junction box/receptacle. This is the recommended
location. For replacement purposes, the location of the existing
utilities may be utilized provided they do not interfere with the sides
or rear of the range. Check local building codes for permissible gas
valve locations.
An external manual shut-off valve must be installed between the gas
inlet and the range for the purpose of turning on or shutting off gas to
the appliance.
The installation must allow for the following:
Access to the gas shut-off valve when the unit is installed.
Access to the remote circuit breaker panel/fuse box when the range
is in place.
The gas supply piping, gas shut-off valve and the electrical junction
box or receptacle must be located so they do not interfere with the
range when it is installed.
The junction box and gas shut off valve must be located so that
the range can be pulled out for service while the appliance remains
connected.
Cabinet Layout
Carefully check the location where the range is to be installed. For
best performance, the range should be placed away from drafts that
may be caused by doors, windows and heating and air conditioning
outlets.
To reduce the risk of personal injury and to reduce accumulated
smoke in the room, Dacor strongly recommends installing a range
hood. A range hood should project horizontally a minimum of five (5)
inches beyond the face of the cabinets.
All maximum and minimum dimensions and clearances shown in the
diagram below must be maintained for safe operation.
The range may be installed flush to the rear wall. A non-combustible
rear wall is not mandatory, but Dacor highly recommends installing
a non-combustible material from the countertop level up to the vent
hood or installation of a backguard.
Any openings in the wall behind the appliance or in the floor
underneath it must be sealed.
REQUIRED CABINET DIMENSIONS
Cabinet tolerances: -1/16”, (+1.6mm) -0
Document # PG05 - 006
Revised 1/26/10