Document # PGCI-027 COMBINATION INSTALLATIONS DR30EI[F]S Range with ERV3015 Raised Vent Revised 10/15/12 Page 1/1 PLANNING GUIDE All tolerances +1/16" (+1.6 mm), -0 unless otherwise noted. ■■ Only models DR30EIS and DR30EIFS may be installed with a raised vent. Use only Dacor raised vent model ERV3015. ■■ A self-rimming countertop configuration is required for raised vent installation. On installations with a raised vent, when sliding the range into position, it will stop when the rear of the control panel or side panels contact the notches toward the front of the countertop. ■■ The self-rimming installation of the DR30DI range and ERV3015 raised vent create a "built-in" look where the range trim overlaps the countertop on both sides and the raised vent overlaps the countertop in back. Countertop height: 34 3/4" (88.3 cm) min. 36 7/8" (93.7 cm) max. Countertop thickness: 1 5/8" (4.1 cm) max. 25 9/16" (64.9 cm) 3/8" min. (1.0 cm) flat countertop overhang Range trim resting on countertop 10" min. (25.4 cm) to any combustibles above counter both sides Rear wall or 3/8" min. (1.0 cm) countertop edge countertop overhang Countertop 27 1/2" (69.9 cm) raised vent opening 24 3/8" (61.9 cm) max. Countertop front 29 1/4" (74.3 cm) countertop opening 30 1/16" (76.2 cm) cabinet opening below countertop Notch countertop to width of cabinets Cabinet face below countertop 2 5/8" (6.7 cm) 19 3/4" 19 3/4" (50.2 cm) (50.2 cm) to 22 3/4" (57.8 cm) ERV3015 raised vent 3/8" min. (1.0 cm) space required behind ERV3015 chassis to clear stiffener DR30EI[F]S range Top View - Downdraft ERV30[15] with Slide-In, Self-Rimming Installation using 3" Side Panels Installed 10" min. (25.4 cm) to any combustibles above counter both sides Rear wall or 3/8" min. (1.0 cm) countertop edge countertop overhang 25 9/16" (64.9 cm) 3/8" min. (1.0 cm) flat countertop overhang Range trim resting on countertop 27 1/2" (69.9 cm) raised vent opening 2 5/8" (6.7 cm) Countertop Cabinet face Back of side panel rests against cabinet face 3 inch side panel 24 3/8" (61.9 cm) max. Countertop front 29 1/4" (74.3 cm) countertop opening 30 1/16" (76.2 cm)* cabinet opening below countertop Notch countertop to width of cabinets Cabinet face below countertop 22 3/4" (57.8 cm) ERV3015 raised vent 3/8" min. (1.0 cm) space required behind ERV3015 chassis to clear stiffener DR30EI[F]S range Cabinet face Top View - Downdraft ERV30[15] with Slide-In, Self-Rimming Installation using 3" Side Panels Removed * To create a "built-in look" on the front of the cabinet, this dimension may be changed to 29 1/4" (74.3 cm), with the width at the notches remaining 30 1/16". This configuration is only for models DR30EIS and DR30EIFS with side panels behind door removed. All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093

  • 1

All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
COMBINATION INSTALLATIONS
DR30EI[F]S Range with ERV3015
Raised Vent
Document # PGCI-027
Revised 10/15/12
Page 1/1
All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.
Only models DR30EIS and DR30EIFS may be installed with a raised
vent. Use only Dacor raised vent model ERV3015.
A self-rimming countertop configuration is required for raised vent
installation. On installations with a raised vent, when sliding the range
into position, it will stop when the rear of the control panel or side
panels contact the notches toward the front of the countertop.
The self-rimming installation of the DR30DI range and ERV3015
raised vent create a “built-in” look where the range trim overlaps the
countertop on both sides and the raised vent overlaps the countertop
in back.
* To create a “built-in look” on the front of the cabinet, this dimension may be changed to 29 1/4” (74.3 cm), with the width at the notches remaining 30
1/16”. This configuration is only for models DR30EIS and DR30EIFS with side panels behind door removed.
TOP VIEW - DOWNDRAFT ERV30[15] WITH SLIDE-IN, SELF-RIMMING INSTALLATION USING
3” SIDE PANELS REMOVED
TOP VIEW - DOWNDRAFT ERV30[15] WITH SLIDE-IN, SELF-RIMMING INSTALLATION USING
3” SIDE PANELS INSTALLED
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
raised vent opening
27 1/2” (69.9 cm)
30 1/16” (76.2 cm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets
3/8” min. (1.0 cm)
countertop overhang
10” min. (25.4 cm)
to any combustibles
above counter both sides
19 3/4”
(50.2 cm)
to
22 3/4”
(57.8 cm)
19 3/4”
(50.2 cm)
2 5/8” (6.7 cm)
24 3/8”
(61.9 cm)
max.
Countertop front
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
raised vent opening
27 1/2” (69.9 cm)
30 1/16” (76.2 cm)*
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets
3/8” min. (1.0 cm)
countertop overhang
10” min. (25.4 cm)
to any combustibles
above counter both sides
22 3/4”
(57.8 cm)
2 5/8” (6.7 cm)
24 3/8”
(61.9 cm)
max.
Countertop front
Countertop height: 34 3/4” (88.3 cm) min.
36 7/8” (93.7 cm) max.
Countertop thickness: 1 5/8” (4.1 cm) max.
Cabinet face
Countertop
Range trim resting
on countertop
DR30EI[F]S range
3/8” min. (1.0 cm)
flat countertop
overhang
25 9/16” (64.9 cm)
ERV3015
raised vent
3/8” min. (1.0 cm) space
required behind ERV3015
chassis to clear stiffener
Cabinet face
Countertop
Range trim resting
on countertop
Back of
side panel
rests against
cabinet face
DR30EI[F]S range
3/8” min. (1.0 cm)
flat countertop
overhang
25 9/16” (64.9 cm)
3 inch
side panel
ERV3015
raised vent
3/8” min. (1.0 cm) space
required behind ERV3015
chassis to clear stiffener