Dacor ERD60 Installation Instruction - Epicure Range - Page 12

Verifying Proper Operation, Installing the Burner Components, Re-Installing the Oven Doors

Page 12 highlights

Installation Instructions Installing the Burner Components Verifying Proper Operation WARNING Never attempt to operate the cooktop section of the range with any of the burner rings, burner caps or grates removed. 1. Remove the brass burner rings, porcelain burner caps, and porcelain gates from their shipping packages. 2. Place each burner ring onto its corresponding burner base, being certain that the five alignment tabs slide into the matching notches in the base. 3. Set each porcelain burner cap on top of its corresponding burner ring. Place the oven exhaust cover over the opening in the top frame. 4. Place each grate onto the top frame, being certain that the rubber feet are positioned in the locating dimples. Re-Installing the Oven Doors 1. Grasp the oven door on opposite sides and lift it until the door hinges are aligned with the openings in the oven frame. Lift door up to 30° angle, then pull door away 30° from the range oven section. 2. Holding the door at about a 30˚ angle from the horizontal, slide the hinges into the openings until the bottom hinge arms drop fully into the hinge receptacles. 3. Lower the door to the fully opened position, and then rotate the two hinge catches toward the oven. 4. Open and close the door completely to ensure that it is properly installed. 5. Peel off the protective layer of plastic that covers the door panel. WARNING • Before operating the range, read the accompanying use and care manual completely. Important safety, service and warranty information is contained in the use and care manual. • The range and shut-off valve must be disconnected from the gas supply piping during any pressure testing exceeding 1/2 psi (3.5kPa). • The range must be isolated from the gas supply piping by closing the shut-off valve during any pressure testing at or below 1/2 psi (3.5 kPa). 1. Before beginning the test procedure, make sure all cooktop control valves are in the OFF position, and all burner rings, burner cap, and grates are properly positioned on the top frame. Turn on the gas supply at the shut-off valve. 2. Turn on the power supply to the range. 3. Set the time of day by pressing the CLOCK key and then pressing either of the TIME • TEMP keys to advance or reduce the time in the display in the desired setting. 4. Press the BAKE key. Select a temperature of 350˚F by pressing the TIME • TEMP "+" key. The display should show "BAKE ON". Press the CANCEL • SECURE key to stop the oven heating process. 5. Test each top burner separately by pressing and turning one control knob at a time counterclockwise to the HIGH position. All ignitors will spark continuously, but only the burner with gas flowing to it will ignite. It will take approximately 4 seconds for ignition to occur, at which time the ignitors will stop sparking. If ignition does not occur within 4 seconds, turn off the knob, wait for at least 2 minutes to allow any gas to dissipate, then repeat this ignition test. The control knob can then be rotated counterclockwise from HIGH to LOW to adjust the flame height progressively. Repeat the ignition test for all burners. When installed properly, the flame will be steady and quiet. It will also have a sharp, blue inner cone that will vary in length proportional to the burner size. If the range does not operate properly, follow these troubleshooting steps: 1. Verify that power and gas are supplied to the range. 2. Check the electrical connections and gas supply to ensure that the installation has been completed correctly. 3. Repeat the above bake test or burner ignition test. 4. If the appliance still does not work, contact an authorized Dacor service company at (800) 793-0093. Do not attempt to repair the appliance yourself. Dacor is not responsible for service required to correct a faulty installation. 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

10
Installation Instructions
Verifying Proper Operation
WARNING
Before operating the range, read the accompanying use
and care manual completely. Important safety, service
and warranty information is contained in the use and care
manual.
The range and shut-off valve must be disconnected
from the gas supply piping during any pressure testing
exceeding 1/2 psi (3.5kPa).
The range must be isolated from the gas supply piping by
closing the shut-off valve during any pressure testing at or
below 1/2 psi (3.5 kPa).
Before beginning the test procedure, make sure all cooktop
1.
control valves are in the
OFF
position, and all burner rings,
burner cap, and grates are properly positioned on the top
frame. Turn on the gas supply at the shut-off valve.
Turn on the power supply to the range.
2.
Set the time of day by pressing the
3.
CLOCK
key and then
pressing either of the
TIME • TEMP
keys to advance or
reduce the time in the display in the desired setting.
Press the
4.
BAKE
key. Select a temperature of 350˚F by
pressing the
TIME • TEMP
+
” key. The display should show
“BAKE ON”
. Press the
CANCEL • SECURE
key to stop the
oven heating process.
Test each top burner separately by pressing and turning one
5.
control knob at a time counterclockwise to the
HIGH
position.
All ignitors will spark continuously, but only the burner
with gas flowing to it will ignite. It will take approximately 4
seconds for ignition to occur, at which time the ignitors will
stop sparking. If ignition does not occur within 4 seconds,
turn off the knob, wait for at least 2 minutes to allow any gas
to dissipate, then repeat this ignition test. The control knob
can then be rotated counterclockwise from
HIGH
to
LOW
to adjust the flame height progressively. Repeat the ignition
test for all burners. When installed properly, the flame will be
steady and quiet. It will also have a sharp, blue inner cone
that will vary in length proportional to the burner size.
If the range does not operate properly, follow these
troubleshooting steps:
Verify that power and gas are supplied to the range.
1.
Check the electrical connections and gas supply to ensure
2.
that the installation has been completed correctly.
Repeat the above bake test or burner ignition test.
3.
If the appliance still does not work, contact an authorized
4.
Dacor service company at (800) 793-0093. Do not attempt
to repair the appliance yourself. Dacor is not responsible for
service required to correct a faulty installation.
Installing the Burner Components
WARNING
Never attempt to operate the cooktop section of the range
with any of the burner rings, burner caps or grates removed.
Remove the brass burner rings, porcelain burner caps, and
1.
porcelain gates from their shipping packages.
Place each burner ring onto its corresponding burner base,
2.
being certain that the five alignment tabs slide into the
matching notches in the base.
Set each porcelain burner cap on top of its corresponding
3.
burner ring. Place the oven exhaust cover over the opening in
the top frame.
Place each grate onto the top frame, being certain that the
4.
rubber feet are positioned in the locating dimples.
Re-Installing the Oven Doors
Grasp the oven door on opposite sides and lift it until the door
1.
hinges are aligned with the openings in the oven frame.
Holding the door at about a 30˚ angle from the horizontal,
2.
slide the hinges into the openings until the bottom hinge arms
drop fully into the hinge receptacles.
Lower the door to the fully opened position, and then rotate
3.
the two hinge catches toward the oven.
Open and close the door completely to ensure that it is
4.
properly installed.
Peel off the protective layer of plastic that covers the door
5.
panel.
30°