Before You Call for Service

Page 7 highlights

Before You Call for Service Problem Solution Guide problem Nothing works. Vent intake raises or lowers partially then stops. Gas flame is being pulled by draw of vent. may be caused by what to DO Raised vent not connected to elec- Make sure power plug is connected to electri- trical power. cal outlet. Power to vent's electrical outlet is Turn on power at circuit breaker or fuse box. off. Check for tripped breaker or blown fuse. Power outage. Contact power company. An obstruction is interfering with the vent intake movement. Immediately press Up/Down switch, then disconnect the power plug. Remove the obstruction. Reconnect the vent power plug and press Up/Down switch to raise or lower intake. Short duct run or high output of Reduce blower speed to a lower setting. system make ventilating force very strong. 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

5
Before You Call for Service
Problem Solution Guide
PROBLEM
MAY BE CAUSED BY
WHAT TO DO
Nothing works.
Raised vent not connected to elec-
trical power.
Make sure power plug is connected to electri-
cal outlet.
Power to vent’s electrical outlet is
off.
Turn on power at circuit breaker or fuse box.
Check for tripped breaker or blown fuse.
Power outage.
Contact power company.
Vent intake raises or lowers
partially then stops.
An obstruction is interfering with
the vent intake movement.
Immediately press Up/Down switch, then dis-
connect the power plug. Remove the obstruc-
tion. Reconnect the vent power plug and press
Up/Down switch to raise or lower intake.
Gas flame is being pulled by
draw of vent.
Short duct run or high output of
system make ventilating force very
strong.
Reduce blower speed to a lower setting.