Dacor IVS2 Planning Guides - Page 1

Dacor IVS2 Manual

Page 1 highlights

Document # PG07 - 006 IVS1, IVS2, IVSR1, IVSR2 Integrated Ventilation System Revised 02/24/10 Page 1/1 PLANNING GUIDE warning • Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. • This appliance must be installed in accordance with the accompanying installation instructions. All tolerances: ±1/16" (±1.6 mm) unless otherwise stated. 8" (20,3 cm) round exhaust with back draft damper Electrical access holes 6" (15.2 cm) 21 1/4" (54.0 cm) 22 1/2" (57.2 cm) 11 1/16" (28.1 cm) 12 1/4" (31.1 cm) 33 1/4" (84.5 cm) 34 1/2" (87.6 cm) 8" (20,3 cm) round exhausts with back draft damper Electrical access holes 6" (15.2 cm) 11 1/16" (28.1 cm) 12 1/4" (31.1 cm) IVS2/ivsR2 overall dimensions 6 1/2" 6 1/2" (16.5 cm) (16.5 cm) CL CL CL CL IVS1/IVSR1 overall dimensions CL CL 8" Exhaust IVS2/ivsR2 exhaust dimensions - top view 10 inch round 8" Exhaust IVS1/ivsR1 exhaust dimensions - top view NOTE: The Dacor IHL series integrated hood liner is designed for use with all Dacor IVS series integrated ventilation systems. Together the IVS and IHL series products can be built into a custom hood structure to provide the required ventilation and heat resistant, easy to clean surfaces. 2" (5.1 cm) 13" (33.0 cm) 21" (53.3 cm) 8" (20.3 cm) ATD10 dimensions - For use with IVS2 and IVSR2 (sold separately) Model No. IVS1 IVSR1 IVS2 IVSR2 Dedicated Circuit Required 120 Vac, 60 Hz., 15 Amp. Min. grounded, dedicated circuit Maximum Duct Length Maximum 60 equivalent straight feet Total Connected Load 0.2 kW (2 Amp.) 0.2 kW (1.5 Amp.)* 0.4 kW (3 Amp.) 0.2 kW (1.5 Amp.)* * Does not include remote blower. ** Remote blower required. Use only Dacor REMP series remote blower *** At zero inches static pressure Blower Configuration Internal Remote** Internal Remote** Blower Rating 600 CFM Nom. See REMP specifications 1200 CFM Nom. See REMP specifications Approximate Shipping Weight 25 lbs. 21 lbs. 38 lbs. 29 lbs. Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.Dacor.com Phone: (800) 793-0093 7.7

  • 1

PLANNING
GUIDE
www.Dacor.com
Phone: (800) 793-0093
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
7.7
IVS1, IVS2, IVSR1, IVSR2
Integrated Ventilation System
21 1/4"
(54.0 cm)
22 1/2"
(57.2 cm)
6” (15.2 cm)
11 1/16"
(28.1 cm)
12 1/4"
(31.1 cm)
Electrical
access
holes
8" (20,3 cm) round exhaust
with back draft damper
IVS1/IVSR1 OVERALL DIMENSIONS
33 1/4"
(84.5 cm)
34 1/2"
(87.6 cm)
6” (15.2 cm)
11 1/16"
(28.1 cm)
12 1/4"
(31.1 cm)
8" (20,3 cm) round exhausts
with back draft damper
Electrical
access
holes
IVS2/IVSR2 OVERALL DIMENSIONS
21" (53.3 cm)
8" (20.3 cm)
13" (33.0 cm)
10 inch round
2" (5.1 cm)
8" Exhaust
C
L
C
L
IVS1/IVSR1 EXHAUST DIMENSIONS - TOP VIEW
8" Exhaust
C
L
C
L
C
L
C
L
6 1/2"
(16.5 cm)
6 1/2"
(16.5 cm)
IVS2/IVSR2 EXHAUST DIMENSIONS - TOP VIEW
ATD10 DIMENSIONS - FOR USE WITH IVS2 AND IVSR2
(SOLD SEPARATELY)
Model No.
Dedicated Circuit
Required
Maximum
Duct Length
Total
Connected Load
Blower
Configuration
Blower Rating
Approximate
Shipping Weight
IVS1
120 Vac, 60 Hz.,
15 Amp. Min.
grounded,
dedicated circuit
Maximum 60
equivalent
straight feet
0.2 kW (2 Amp.)
Internal
600 CFM Nom.
25 lbs.
IVSR1
0.2 kW (1.5 Amp.)*
Remote**
See REMP specifications
21 lbs.
IVS2
0.4 kW (3 Amp.)
Internal
1200 CFM Nom.
38 lbs.
IVSR2
0.2 kW (1.5 Amp.)*
Remote**
See REMP specifications
29 lbs.
*
Does not include remote blower.
**
Remote blower required. Use only Dacor REMP series remote blower
***
At zero inches static pressure
All tolerances: ±1/16” (±1.6 mm) unless otherwise stated.
Document # PG07 - 006
Revised 02/24/10
Page 1/1
WARNING
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
This appliance must be installed in accordance with the
accompanying installation instructions.
NOTE:
The Dacor IHL series integrated hood liner is designed for use with
all Dacor IVS series integrated ventilation systems. Together the IVS and
IHL series products can be built into a custom hood structure to provide the
required ventilation and heat resistant, easy to clean surfaces.