Planning, Guide

Page 3 highlights

Document # PG03-001 MET304 and METB365-1 30 Inch and 36 Inch Wide, Discovery Electric Cooktops All tolerances: +1/16", -0, (+1.6 mm, -0) unless otherwise stated Revised 10/01/11 Page 3/3 PLANNING GUIDE 3/8" min. (1.0 cm) flat countertop overhang required behind cutout Countertop 5/8" min. (1.6 cm) flat countertop overhang required behind cutout Countertop Stiffener ETT or MET series cooktop Cabinet face 3/8" min. (1.0 cm) space behind raised vent chassis to clear stiffener ERV or PRV series raised vent: Check raised vent dimensions/specifications to determine proper fit Floor ERV and PRV series raised vent installation side view D B E Stiffener ETT or MET series cooktop Cabinet face 5/8" min. (1.6 cm) space behind raised vent chassis to clear stiffener RV series raised vent: Check raised vent dimensions/specifications to determine proper fit 4 5/8" (11.7 cm) 9 7/8" (25.1 cm) with CABP3 blower installed Floor RV series raised vent installation side view Rear wall C 19 3/4" (50.2 cm) Cabinet face 1" min. (2.5 cm) 6" (15.2 cm) min. from mounting surface to combustibles below cooktop chassis 6" min. A 6" min. (15.2 cm) (15.2 cm) countertop cutoUT (with raised vent) top view countertop cutoUT (with raised vent) ISO view Model/Configuration MET304 cooktop with ERV30 or PRV30 raised vent MET304 cooktop with RV30 raised vent METB365-1 cooktop with ERV36 or PRV36 raised vent METB365-1 cooktop with RV36 raised vent (A) Cooktop Cutout Width 28 3/4" (73.0 cm) 34 3/4" (88.3 cm) (B) Raised Vent Cutout Width 27 3/4" (70.5 cm) 33 3/4" (85.7 cm) (C) Total Cutout Depth 22 1/2" (57.2 cm) 22 1/4" (56.5 cm) 22 1/2" (57.2 cm) 22 1/4" (56.5 cm) (D) Raised Vent Cutout Depth 2 3/4" (7.0 cm) 2 1/2" (6.4 cm) 2 3/4" (7.0 cm) 2 1/2" (6.4 cm) (E) Minimum Rear Countertop Overhang 3/8" (1.0 cm) 5/8" (1.6 cm) 3/8" (1.0 cm) 5/8" (1.6 cm) Specifications subject to change without notice. www.dacor.com Phone: (800) 7933-0.3093

  • 1
  • 2
  • 3

PLANNING
GUIDE
Specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
30 Inch and 36 Inch Wide,
Discovery Electric Cooktops
Stiffener
Cabinet face
Countertop
Floor
3/8” min. (1.0 cm) space
behind raised vent
chassis to clear stiffener
3/8” min. (1.0 cm)
flat countertop overhang
required behind cutout
ERV or PRV series raised
vent: Check raised vent
dimensions/specifications
to determine proper fit
ETT or MET series cooktop
19 3/4"
(50.2 cm)
6" min.
(15.2 cm)
6" min.
(15.2 cm)
1" min.
(2.5 cm)
Cabinet
face
A
B
C
D
E
6" (15.2 cm) min.
from mounting surface to
combustibles below
cooktop chassis
Rear
wall
Stiffener
Cabinet face
Countertop
Floor
5/8” min. (1.6 cm) space
behind raised vent
chassis to clear stiffener
4 5/8” (11.7 cm)
9 7/8” (25.1 cm) with
CABP3 blower installed
5/8” min. (1.6 cm)
flat countertop overhang
required behind cutout
RV series raised vent:
Check raised vent
dimensions/specifications
to determine proper fit
ETT or MET series cooktop
ERV AND PRV SERIES RAISED VENT INSTALLATION
SIDE VIEW
RV SERIES RAISED VENT INSTALLATION
SIDE VIEW
COUNTERTOP CUTOUT (WITH RAISED VENT)
TOP VIEW
COUNTERTOP CUTOUT (WITH RAISED VENT)
ISO VIEW
MET304 and METB365-1
All tolerances: +1/16”, -0,
(+1.6 mm, -0) unless otherwise stated
Document # PG03-001
Revised 10/01/11
Page 3/3
Model/Configuration
(A) Cooktop
Cutout Width
(B) Raised Vent
Cutout Width
(C) Total Cutout
Depth
(D) Raised Vent
Cutout Depth
(E) Minimum
Rear Countertop
Overhang
MET304 cooktop with ERV30 or PRV30
raised vent
28 3/4”
(73.0 cm)
27 3/4”
(70.5 cm)
22 1/2”
(57.2 cm)
2 3/4”
(7.0 cm)
3/8”
(1.0 cm)
MET304 cooktop with
RV30 raised vent
22 1/4”
(56.5 cm)
2 1/2”
(6.4 cm)
5/8”
(1.6
cm)
METB365-1 cooktop with ERV36 or
PRV36 raised vent
34 3/4”
(88.3 cm)
33 3/4”
(85.7 cm)
22 1/2”
(57.2 cm)
2 3/4”
(7.0 cm)
3/8”
(1.0 cm)
METB365-1
cooktop with RV36 raised
vent
22 1/4”
(56.5 cm)
2 1/2”
(6.4 cm)
5/8”