Document # PG01-001 EO, MOH, MOV 27 and 30 Inch Wide, Single, Discovery Wall Ovens Revised 10/01/11 Page 2/2 PLANNING GUIDE Cutout tolerances: +1/16" (+1.6 mm), -0, unless otherwise stated. 1 1/2" (3.8 cm) typical counter 36" Typical (91.4 cm) 1 ¾" (4.5 cm) min. to combustible floor Recommended electrical location 1" (2.5 cm) min. to combustibles 4" (10.2 cm) min. between cutout A B 3/4" (1.9 cm) support platform 4" typical toe kick (shown) A B 3/4" (1.9 cm) support platform Alternate electrical locations CUTOUT DIMENSIONS SIDE-BY-SIDE UNDER-COUNTER installation C Recommended electrical location Model EO127 MOH127 MOV127 EO130 MOH130 MOV130 A 27 7/16" (69.7 cm) B 25 1/2" (64.8 cm) 28 1/2" (72.4 cm) C 27" (68.6 cm) 30" (76.2 cm) 1" (2.5 cm) min. clear to bottom of door 1 ¾" (4.5 cm) min. clear to top of door for heat exhaust A B 3/4" (1.9 cm) support platform Alternate electrical location 31 1/4" (79.4 cm) recommended (may be altered) 4" typical toe kick (shown) CUTOUT DIMENSIONS 1 1/2" (3.8 cm) typical counter 1" (2.5 cm) min. to combustibles 36" Typical (91.4 cm) 1 ¾" (4.5 cm) min. to combustible floor A B 3/4" (1.9 cm) support platform 4" typical toe kick (shown) Recommended electrical location CUTOUT DIMENSIONS UNDER-COUNTER installation NOTES: 1. 24" (61.0 cm) minimum interior cabinet depth.Back of cabinet may need to be removed. 2. 3/4" (1.9 cm) support platform (flush with cutout). 3. 1/8" (3 mm) minimum clearance from appliance to adjacent cabinet doors/drawers. 4. Two (2) Single Ovens are not approved in a stack configuration. Specifications subject to change without notice. www.dacor.com Phone: (800) 7931-0.2093

  • 1
  • 2

PLANNING
GUIDE
Specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
27 and 30 Inch Wide, Single,
Discovery Wall Ovens
EO, MOH, MOV
NOTES:
1.
24” (61.0 cm) minimum interior cabinet depth.Back of
cabinet may need to be removed.
2.
3/4” (1.9 cm) support platform (flush with cutout).
CUTOUT DIMENSIONS
C
A
B
4“ typical toe kick (shown)
Alternate
electrical
location
3/4” (1.9 cm)
support platform
Recommended
electrical
location
31 1/4” (79.4 cm)
recommended
(may be altered)
1 ¾“ (4.5 cm) min.
clear to top of
door for heat
exhaust
1“ (2.5 cm)
min. clear to
bottom
of door
CUTOUT DIMENSIONS -
UNDER-COUNTER INSTALLATION
36” Typical
(91.4 cm)
1 1/2”
(3.8 cm)
typical counter
4“ typical toe kick (shown)
1“ (2.5 cm) min. to combustibles
A
B
3/4” (1.9 cm)
support platform
Recommended
electrical
location
1 ¾“ (4.5 cm) min.
to combustible floor
Model
A
B
C
EO127
27 7/16”
(69.7 cm)
25 1/2”
(64.8 cm)
27”
(68.6 cm)
MOH127
MOV127
EO130
28 1/2”
(72.4 cm)
30”
(76.2 cm)
MOH130
MOV130
3.
1/8” (3 mm) minimum clearance from appliance to
adjacent cabinet doors/drawers.
4.
Two (2) Single Ovens are not approved in a stack
configuration.
Alternate
electrical
locations
4“ (10.2 cm) min.
between cutout
Recommended electrical location
4“ typical toe kick (shown)
1“ (2.5 cm) min. to combustibles
A
B
3/4” (1.9 cm)
support platform
A
B
3/4” (1.9 cm)
support platform
36” Typical
(91.4 cm)
1 1/2”
(3.8 cm)
typical counter
1 ¾“ (4.5 cm) min.
to combustible floor
CUTOUT DIMENSIONS
SIDE-BY-SIDE UNDER-COUNTER INSTALLATION
Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated.
Document # PG01-001
Revised 10/01/11
Page 2/2