Dacor PHG30 Installation Instructions - Page 5

Installation Specifications

Page 5 highlights

Installation Specifications WARNING • Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. • The minimum installed distance from the rear of blower unit base to the cooktop surface must be no less than 30" inches (76.2 cm), 26 inches (66.0 cm) for an electric cooktop. The minimum specified distance may be higher for the particular range or cooktop in use. Check the manufacturers specifications for the cooktop or range. Product Dimensions Tolerances: ±1/16" (±1.6 mm), -0 unless otherwise stated 10 3/4" (27.3 cm) 11 7/8" (30.2 cm) Planning the Location • Carefully check the location where the hood is to be installed. The hood should be placed for convenient access. Make certain that electrical power can be provided in the selected location. • Plan the installation so that all minimum dimensions shown are met or exceeded. Dimensions shown provide minimum clearances, unless otherwise noted. • All contact surfaces between the hood and any cabinets or walls must be solid and at right angles. • Install the range hood and cooking appliance(s) so that they can be removed if service is required. 26 1/8" (66.4 cm) min.* 44" (111.8 cm) max.* 25 3/8" * 19 3/4" * (64.5 cm) (50.2 cm) 8" dia. 203.2 cm) 5/16" (3 mm) 30" min. (76.2 cm) Rear of blower unit Glass Cooktop surface 5 3/4" (14.6 cm) 19 3/4" (50.2 cm) 30" (76.2 cm) or 36" (91.4 cm)** * Glass thickness of 5/16" (3 mm) not included ** Glass width must be specified at time of order. Specify glass part number: PHGXXBK where XX is the width. Operating Specifications Blower Blower Speeds Lights Filters Exhaust Finish Total Connected Load Circuit Requirement 600 CFM max. 4 with electronic speed control 120 Vac, 50 Watt, halogen (1) Mesh type, dishwasher safe (2) 8 inch 430 stainless steel with tempered glass hood 120 Vac, 60 Hz. 3.5 Amp. 120 Vac, 15 Amp. grounded, dedicated circuit, min. Side View NOTE: The mounting hardware included with the hardware packet is suitable for mounting to brick and masonry only. If mounting the range hood to drywall, Dacor strongly recommends the using an anchoring system designed for use with drywall. In addition, Dacor strongly recommends that you install a reinforced mounting block between the studs behind all hood mounting locations. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

3
Planning the Location
Carefully check the location where the hood is to be
installed. The hood should be placed for convenient
access. Make certain that electrical power can be
provided in the selected location.
Plan the installation so that all minimum dimensions
shown are met or exceeded. Dimensions shown pro-
vide minimum clearances, unless otherwise noted.
All contact surfaces between the hood and any cabi-
nets or walls must be solid and at right angles.
Install the range hood and cooking appliance(s) so
that they can be removed if service is required.
NOTE:
The mounting hardware includ-
ed with the hardware packet is suitable
for mounting to brick and masonry
only. If mounting the range hood to dry-
wall, Dacor strongly recommends the
using an anchoring system designed
for use with drywall. In addition, Dacor
strongly recommends that you install a
reinforced mounting block between the
studs behind all hood mounting loca-
tions.
WARNING
Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
The minimum installed distance from the rear of
blower
unit base to the cooktop surface must be
no less than 30” inches (76.2 cm), 26 inches (66.0
cm) for an electric cooktop. The minimum specified
distance may be higher for the particular range or
cooktop in use. Check the manufacturers specifica-
tions for the cooktop or range.
Product Dimensions
Tolerances: ±1/16” (±1.6 mm), -0 unless otherwise stated
Operating Specifications
Blower
600 CFM max.
Blower Speeds
4 with electronic speed control
Lights
120 Vac, 50 Watt, halogen (1)
Filters
Mesh type, dishwasher safe (2)
Exhaust
8 inch
Finish
430 stainless steel
with tempered glass hood
Total Connected Load
120 Vac, 60 Hz. 3.5 Amp.
Circuit
Requirement
120 Vac, 15 Amp. grounded,
dedicated circuit, min.
Installation Specifications
5 3/4”
(14.6 cm)
8” dia.
203.2 cm)
10 3/4” (27.3 cm)
11 7/8” (30.2 cm)
26 1/8” (66.4 cm)
min.*
44” (111.8 cm)
max.*
25 3/8” *
(64.5 cm)
19 3/4”
(50.2 cm)
19 3/4” *
(50.2 cm)
30” (76.2 cm) or
36” (91.4 cm)**
* Glass thickness of 5/16” (3 mm) not included
** Glass width must be specified at time of order. Specify glass
part number: PHGXXBK where XX is the width.
5/16”
(3 mm)
30” min.
(76.2 cm)
Rear of blower
unit
Cooktop
surface
Glass
Side View