Dacor REMP3 Planning Guides - Page 3

Remote Blowers

Page 3 highlights

Discharge REMP3, REMP16 Revised 06/11/08 Remote Blowers PLANNING 3/3 GUIDE +/- 1/16" (+/- 1.6mm) unless otherwise stated Blower Wiring/Conduit Roof Wiring/Conduit Duct Duct Wall No obstructions within 15 inches of discharge sample REMP Roof Installation (Side View) Blower Discharge NOTE: 1. The REMP chassis may be rotated to clear obstructions. 15" (381mm) min. clearance must be maintained from the air discharge to any obstruction. When mounting in a horizontal position, shield the REMP to protect from possible water collection in the chassis. Maintain a minimum down slope of 1/4" (6mm) per foot for evacuation of water. 2. When the REMP is installed on to a flat (less than a 2:12 pitch) roof, a roof curb is required. 3. The blower discharge must be pointed in the same direction as the prevailing wind. Prevailing wind Roof curb Blower discharge REMP flat roof installation (Top & Side Views) 25 1/2" (648mm) 2" (51mm) 6" (152mm) 2" (51mm) 19" (483mm) 23 1/4" (591mm) REMp3 roof curb dimensions 33 1/2" (851mm) 2" (51mm) 6" (152mm) 2" (51mm) 26" (660mm) 30 1/2" (776mm) REMp16 roof curb dimensions *All the CFM Blower Ratings are valued at 0" (zero-inch) static pressure. Web: http://www.Dacor.com Corporate Phone: 800-793-0093 Specifications are subject to change without notice. See installation instructions for additional details. 9.5

  • 1
  • 2
  • 3

PLANNING
GUIDE
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
9.5
Remote Blowers
REMP3, REMP16
Blower
discharge
Roof curb
Prevailing
wind
REMP FLAT ROOF INSTALLATION
(Top & Side Views)
25 1/2"
(648mm)
2"
(51mm)
19"
(483mm)
23 1/4"
(591mm)
6"
(152mm)
2"
(51mm)
REMP3
ROOF CURB DIMENSIONS
NOTE:
1.
The REMP chassis may be rotated to clear
obstructions. 15” (381mm) min. clearance must
be maintained from the air discharge to any
obstruction. When mounting in a horizontal
position, shield the REMP to protect from possible
water collection in the chassis. Maintain a
minimum down slope of 1/4” (6mm) per foot for
evacuation of water.
2.
When the REMP is installed on to a flat (less than a
2:12 pitch) roof, a roof curb is required.
3.
The blower discharge must be pointed in the same
direction as the prevailing wind.
3/3
SAMPLE REMP ROOF INSTALLATION
(Side View)
Blower
Roof
Discharge
Blower
Duct
Wiring/Conduit
Wiring/Conduit
Duct
Wall
No obstructions
within 15 inches of discharge
Discharge
33 1/2"
(851mm)
2"
(51mm)
26"
(660mm)
30 1/2"
(776mm)
6"
(152mm)
2"
(51mm)
REMP16
ROOF CURB DIMENSIONS
*All the CFM Blower Ratings are valued at 0” (zero-inch) static pressure.
Revised
06/11/08
+/- 1/16” (+/- 1.6mm) unless otherwise stated