Dacor REMP3 Installation Instructions - Page 8

Installation Instructions - parts

Page 8 highlights

Installation Instructions warning • If the electrical service provided does not meet the power requirements for the hood/raised vent and the blower combined, do not continue with the installation. Contact a licensed electrician to correct the situation before continuing. • Failure to connect the wiring as specified may result in an electric shock hazard and/or improper blower operation. • To avoid the risk of fire or electric shock, turn off power at the circuit breaker panel or fuse box before connecting the blower to the power source. • The blower assembly is heavy. Do not attempt to lift or move it without assistance. Parts List 2. Remove the blower's top cover by removing the screws around the edge that hold it in place. Figure 6 Verify Package Contents • 2 1/2" wood mounting screws (8) • Blower assembly Parts Required • 3 conductor wiring/conduit with UL certified strain relief on each end (length is determined by remote blower location). • If the blower will be mounted to a surface other than wood, fasteners designed for the material the unit will be mounted to must be provided. The fasteners must be capable of supporting the weight of the blower (see weight table on page 5) and meet local codes and ordinances. • Consult the hood or raised vent installation instructions for additional part requirements. Installation 1. Before installing the blower, unpack the unit and check for physical damage to the motor and blower assembly. To do so, reach in through the intake collar and spin the fan blades slowly. They should spin freely and quietly without vibration. Intake Collar Fan Blades 3. Apply sealant between the blower and the mounting surface where the flange around the edge of the blower will rest. Flange Air Discharge Blower Sealant Sealant 45° Adjustable Elbow Roof Figure 7 Round Duct 4. Pick up the blower assembly and center it on the mounting surface inserting the intake collar into the cutout. 5. While holding the blower in place, fasten it to the mounting surface with eight (8) mounting screws. The mounting holes are located inside the blower assembly chassis near the sides. 6. Install the duct work according to the installation instructions for the hood or raised vent. Support the duct weight as necessary to ensure properly sealed joints. Figure 5 Bottom of Blower 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

6
WARNING
If the electrical service provided does not meet the
power requirements for the hood/raised vent and the
blower combined, do not continue with the instal-
lation. Contact a licensed electrician to correct the
situation before continuing.
Failure to connect the wiring as specified may result
in an electric shock hazard and/or improper blower
operation.
To avoid the risk of fire or electric shock, turn off
power at the circuit breaker panel or fuse box before
connecting the blower to the power source.
The blower assembly is heavy. Do not attempt to lift
or move it without assistance.
Parts List
Verify Package Contents
2 1/2” wood mounting screws (8)
Blower assembly
Parts Required
3 conductor wiring/conduit with UL certified strain relief
on each end (length is determined by remote blower
location).
If the blower will be mounted to a surface other than
wood, fasteners designed for the material the unit will
be mounted to must be provided. The fasteners must
be capable of supporting the weight of the blower (see
weight table on page 5) and meet local codes and ordi-
nances.
Consult the hood or raised vent installation instructions
for additional part requirements.
Installation
Before installing the blower, unpack the unit and check
1.
for physical damage to the motor and blower assembly.
To do so, reach in through the intake collar and spin
the fan blades slowly. They should spin freely and qui-
etly without vibration.
Installation Instructions
Remove the blower’s top cover by removing the screws
2.
around the edge that hold it in place.
Apply sealant between the blower and the mounting
3.
surface where the flange around the edge of the blower
will rest.
Pick up the blower assembly and center it on the
4.
mounting surface inserting the intake collar into the
cutout.
While holding the blower in place, fasten it to the
5.
mounting surface with eight (8) mounting screws. The
mounting holes are located inside the blower assembly
chassis near the sides.
Install the duct work according to the installation
6.
instructions for the hood or raised vent. Support the
duct weight as necessary to ensure properly sealed
joints.
Fan
Blades
Bottom of Blower
Intake
Collar
Figure 5
Figure 6
Sealant
Roof
Air
Discharge
Sealant
Blower
Round Duct
Flange
Figure 7
45° Adjustable
Elbow