Document # PG05-012 RNRP36G, RNRP48G Renaissance 36" and 48" Wide All Gas Ranges ELECTRICAL AND GAS REQUIREMENTS Revised 03/16/15 Page 3/3 PLANNING GUIDE A B BACK OF RANGE Range Model RNRP36G RNRP48G A 13 1/16" to 14 3/8" (33.2 to 36.5 cm) 13 1/16" to 14 3/8" (33.2 to 36.5 cm) B 7 5/16" (18.6 cm) 4 1/4" (10.8 cm) ELECTRICAL REQUIREMENTS Electrical Circuit Required Total Connected Load 120 Vac, 60 Hz, 15 Amp. grounded, dedicated, 3 prong electrical outlet 5.0 Amps. @120 Vac, 60 Hz, Gas Type Natural LP GAS SUPPLY PRESSURE REQUIREMENTS Manifold Pressure* (WC) Min. Gas Supply Pressure (WC) Max. Input Pressure 5" 6" 1/2 psi 10" 11" 1/2 psi IMPORTANT: The information above is for reference only. If the above data does not agree with the product data label, use the data on the product data label on top of the kick plate below the door (see the installation instructions for location). The range comes from the factory with the regulator installed. Use only the installed regulator. The regulator inlet accommodates a 3/4" gas line. The range ships with a 1/2" to 3/4" adapter connected to the regulator. All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093

  • 1
  • 2
  • 3

All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
RNRP36G, RNRP48G
Renaissance
36” and 48” Wide
All Gas Ranges
Document # PG05-012
Revised 03/16/15
Page 3/3
BACK OF RANGE
GAS SUPPLY PRESSURE REQUIREMENTS
Gas
Type
Manifold
Pressure* (WC)
Min. Gas Supply
Pressure (WC)
Max. Input
Pressure
Natural
5”
6”
1/2 psi
LP
10”
11”
1/2 psi
IMPORTANT:
The information above is for reference only. If the above data
does not agree with the product data label, use the data on the product
data label on top of the kick plate below the door (see the installation
instructions for location).
The range comes from the factory with the regulator installed. Use only the
installed regulator. The regulator inlet accommodates a 3/4” gas line. The
range ships with a 1/2” to 3/4” adapter connected to the regulator.
ELECTRICAL REQUIREMENTS
Electrical Circuit
Required
Total Connected
Load
120 Vac, 60 Hz, 15 Amp.
grounded, dedicated, 3 prong
electrical outlet
5.0 Amps. @120 Vac,
60 Hz,
B
A
Range
Model
A
B
RNRP36G
13 1/16” to 14 3/8”
(33.2 to 36.5 cm)
7 5/16”
(18.6 cm)
RNRP48G
13 1/16” to 14 3/8”
(33.2 to 36.5 cm)
4 1/4”
(10.8 cm)
ELECTRICAL AND GAS REQUIREMENTS