RO230, ROV230 Document # PG01-010 30 Inch, Double, Renaissance® Wall Oven Revised 10/01/11 Page 1/2 PLANNING GUIDE Product tolerances: ±1/16" (±1.6 mm) unless otherwise stated K J Utility cutout Top of chassis B F G warning • Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. • This appliance must be installed in accordance with the accompanying installation instructions. H C D 21 1/8" A Control panel front E Control panel side view Top of chassis Conduit: 60" (152 cm) Long 3 1/2" (8.9 cm) 1 1/8" (2.9 cm) 1 1/8" (2.9 cm) 3 3/16" (8.1 cm) (A) Overall (B) Chassis Width Width 29 7/8" (75.9 cm) 28 3/8" (72.1 cm) (C) Overall Height 49 7/8" (126.7 cm) (D) Chassis Height 49" (124.5 cm) (E) Control Panel Overlay 7/8" (2.2 cm) (F) Utility (G) Utility (H) Utility (J) Control (K) Chassis Cutout Width Cutout Height Cutout Depth Panel Depth Depth 6 1/4" (15.9 cm) 4 3/4" (12.1 cm) 7 3/4" (19.7 cm) 1 3/16" (3.0 cm) 23 5/8" (60.0 cm) Epicure Millennia (Order kit #AMOH30)) HANDLE DIMENSIONS ELECTRICAL SPECIFICATIONS Dedicated Circuit Requirements Total Connected Load 240 Vac 60 Hz., 4-wire,* 60 Amp. 11.6 kW (48.6 Amp.) * Two 120 Vac hot (L1 and L2), one neutral, one ground. Fuse/circuit breaker on both L1 and L2. The above specifications are for reference only. See the product data plate for exact specifications. Specifications subject to change without notice. www.dacor.com Phone: (800) 7913-.010593