Dacor RO230 Installation Instructions - Page 8

Installation Specifications

Page 8 highlights

Installation Specifications Installation Planning warning Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. important • Locate the junction box so that the oven may be easily disconnected in the event that it needs to be removed from the wall completely for service. • Install the junction box in a location that allows the oven to be removed from the cut out for service without being disconnected. • Plan the installation so that all minimum clearances are met or exceeded. Dimensions shown provide minimum clearances, unless otherwise noted. Be certain that proper clearance is provided for the oven door when it is in the open position according the Product Dimensions. • Cabinet cutout dimensions must be used as indicated. The specified minimum cabinet depth and width must be provided. The cabinet depth and width must completely enclose the recessed portion of the oven. • If the oven is not installed level it may deliver poor or inconsistent baking results. • All contact surfaces between the appliance and the cabinet must be solid and level. • Carefully check the location where the oven is to be • Provide a platform within the cabinet to support the installed. The oven should be placed for convenient oven. It must be installed level and straight. The top access. Make certain that electrical power, meeting the edge of the platform must be flush with the cut out at specifications on page 4, can be provided in the the front of the cabinet. There are no provisions to level selected location. the oven after it has been installed. 3/4" (1.9 cm) thick • Dacor recommends installing the electrical junction box plywood is recommended. in the one of the locations shown. Cabinet Dimensions Cabinet tolerances: +1/16 (1.6 mm), -0, unless otherwise stated. Model Number RO130S RO130B ROV130B RO230S RO230B ROV230B (N) Minimum Cabinet Width 30" (76.2 cm) 30" (76.2 cm) (P) Minimum Cutout Width (R) Minimum Cutout Height 28 1/2" (72.4 cm) 26 7/8" (68.3 cm) 28 1/2" (72.4 cm) 49 1/8" (124.8 cm) Minimum interior cabinet depth: 24" (61.0 cm) 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

6
Installation Specifications
Installation Planning
WARNING
Observe all governing codes and ordinances during plan-
ning and installation. Contact your local building depart-
ment for further information.
IMPORTANT
Locate the junction box so that the oven may be easily
disconnected in the event that it needs to be removed
from the wall completely for service.
If the oven is not installed level it may deliver poor or
inconsistent baking results.
Carefully check the location where the oven is to be
installed. The oven should be placed for convenient
access. Make certain that electrical power, meeting the
specifications on page 4, can be provided in the
selected location.
Dacor recommends installing the electrical junction box
in the one of the locations shown.
Minimum interior cabinet depth: 24” (61.0 cm)
Install the junction box in a location that allows the
oven to be removed from the cut out for service without
being disconnected.
Plan the installation so that all minimum clearances
are met or exceeded. Dimensions shown provide mini-
mum clearances, unless otherwise noted. Be certain
that proper clearance is provided for the oven door
when it is in the open position according the
Product
Dimensions
.
Cabinet cutout dimensions must be used as indicated.
The specified minimum cabinet depth and width must
be provided. The cabinet depth and width must com-
pletely enclose the recessed portion of the oven.
All contact surfaces between the appliance and the
cabinet must be solid and level.
Provide a platform within the cabinet to support the
oven. It must be installed level and straight. The top
edge of the platform must be flush with the cut out at
the front of the cabinet. There are no provisions to level
the oven after it has been installed. 3/4” (1.9 cm) thick
plywood is recommended.
Model
Number
(N) Minimum
Cabinet Width
(P) Minimum
Cutout Width
(R) Minimum
Cutout Height
RO130S
30” (76.2 cm)
28 1/2” (72.4 cm)
26 7/8” (68.3 cm)
RO130B
ROV130B
RO230S
30” (76.2 cm)
28 1/2” (72.4 cm)
49 1/8” (124.8 cm)
RO230B
ROV230B
Cabinet Dimensions
Cabinet tolerances: +1/16 (1.6 mm), -0, unless otherwise stated.