Definitive Technology UIW RCS III UIW RCSIII Manual - Page 6

Step-by-Step Installation

Page 6 highlights

Step-by-Step Installation (continued) Hole location options and requirements • Mounting in ceiling with joists 12" on-center. - Place template against inside edge of joist. - Trace around template with pencil. - Cut hole. See Diagram 1, page 9 for reference. • Mounting in ceiling with joists wider than 12" on-center. - Place template at least 11/4" away from existing joists (to clear lock arms). - Template does not need to be centered between joists. - Trace around template with pencil. - Cut hole. - Install framing material inside cavity, running 90 degrees to existing joists, leaving 101/2" between frame sides. See Diagram 2, page 9 for reference. • Mounting in ceiling with joists 12" on-center where crossbeam is closer than 11/4" from side of enclosure. - Enclosure MUST be against the crossbeam and 2 joists, boxing it in on 3 sides. Shim as required. - This will require 1 additional #8 x 31/2" wood screw and side gasket material (not included) to secure to crossbeam and prevent rattling. - Place template against crossbeam and mounting joist. - Trace around template with pencil. - Cut hole. 6 See Diagram 3, page 10 for reference.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

6
Step-by-Step Installation
(continued)
Hole location options and requirements
Mounting in ceiling with joists 12" on-center.
Place template against inside edge of joist.
Trace around template with pencil.
Cut hole.
See Diagram 1, page 9 for reference.
Mounting in ceiling with joists wider than 12" on-center.
Place template at least 1
1
/
4
" away from existing joists
(to clear lock arms).
Template does not need to be centered between joists.
Trace around template with pencil.
Cut hole.
Install framing material inside cavity, running 90 degrees to
existing joists, leaving 10
1
/
2
" between frame sides.
See Diagram 2, page 9 for reference.
Mounting in ceiling with joists 12" on-center where crossbeam
is closer than 1
1
/
4
" from side of enclosure.
Enclosure MUST be against the crossbeam and 2 joists, boxing
it in on 3 sides. Shim as required.
This will require 1 additional #8 x 3
1
/
2
" wood screw and side
gasket material (not included) to secure to crossbeam and prevent
rattling.
Place template against crossbeam and mounting joist.
Trace around template with pencil.
Cut hole.
See Diagram 3, page 10 for reference.