Dell Brocade 6510 Brocade Fabric OS v7.0.2 Release Notes v1.0 - Page 47

Fabric OS v7.0.2 Release Notes v1.0, of 99 - series

Page 47 highlights

Close with Code Change in Fabric OS v7.0.2 Defect ID: DEFECT000397135 Technical Severity: Medium Summary: change Port Fencing raslog severity Symptom: Change Port Fencing raslog message FW- 1202 FW-1501 from Warning to Error. No functional impact. Risk of Fix: Low Feature: Infrastructure Probability: Low Function: Other Reported In Release: FOS6.4.3 Defect ID: DEFECT000397275 Technical Severity: Medium Summary: Performing switchdisable,configdefault, portcfgpersistenetenable, portcfgdefault, then portcfgpersistent enable can cause some ports to stay in "FC Disabled" state. Symptom: After a system config default, followed by a series of portcfg default and portcfgpersistentenable's a few ports will still show disabled. Risk of Fix: Low Feature: FOS Software Probability: Medium Function: ASIC Driver Reported In Release: FOS6.4.0 Service Request ID: 724141 Defect ID: DEFECT000397353 Technical Severity: Medium Summary: When issuing the statsclear command it will return an error saying slot0 is non-existent in v7.0.1a Symptom: > statsclear Invalid slot number 0 detected in chassis system. Please use --slot option or setslot command to provide a valid slot. Workaround: Use slotstatsclear command Risk of Fix: Low Feature: FOS Software Probability: High Function: Fabric Services Reported In Release: FOS7.0.1 Service Request ID: 724465 Defect ID: DEFECT000397402 Technical Severity: Medium Summary: Soft parity errors causing disruption on BES/FS8-18 Symptom: If a parity error occurs in the encryption path, frames may be transmitted to the destination carrying an incorrect payload and without being marked with an error. If a parity error occurs in the decryption path, the frame data might not be decrypted successfully. Risk of Fix: Low Feature: FOS Software Probability: Low Function: Fabric Services Reported In Release: FOS6.4.2 Service Request ID: 722589 Defect ID: DEFECT000398718 Technical Severity: High Summary: VEX port on FR4-18i requires Integrated Routing license on FOS v7.0.1 and FOS v7.0.1a; previous releases did not require license. Symptom: Customer can no longer import device and run traffic without Integrated Routing license on FR4-18i Vex port. Risk of Fix: Low Feature: Legacy FCR - 7500/FR4-18i Probability: High Function: Other Reported In Release: FOS7.0.1 Fabric OS v7.0.2 Release Notes v1.0 Page 47 of 99

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Close with Code Change in Fabric OS v7.0.2
Fabric OS v7.0.2 Release Notes v1.0
Page 47 of 99
Defect ID:
DEFECT000397135
Technical Severity:
Medium
Summary:
change Port Fencing raslog severity
Symptom:
Change Port Fencing raslog message FW- 1202 FW-1501 from Warning to Error. No functional
impact.
Risk of Fix:
Low
Feature:
Infrastructure
Probability:
Low
Function:
Other
Reported In Release:
FOS6.4.3
Defect ID:
DEFECT000397275
Technical Severity:
Medium
Summary:
Performing switchdisable,configdefault, portcfgpersistenetenable, portcfgdefault, then
portcfgpersistent enable can cause some ports to stay in "FC Disabled" state.
Symptom:
After a system config default, followed by a series of portcfg default and portcfgpersistentenable's a
few ports will still show disabled.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Medium
Function:
ASIC Driver
Reported In Release:
FOS6.4.0
Service Request ID:
724141
Defect ID:
DEFECT000397353
Technical Severity:
Medium
Summary:
When issuing the statsclear command it will return an error saying slot0 is non-existent in v7.0.1a
Symptom:
> statsclear
Invalid slot number 0 detected in chassis system.
Please use --slot option or setslot command to provide a valid slot.
Workaround:
Use slotstatsclear command
Risk of Fix:
Low
Feature:
FOS Software
Probability:
High
Function:
Fabric Services
Reported In Release:
FOS7.0.1
Service Request ID:
724465
Defect ID:
DEFECT000397402
Technical Severity:
Medium
Summary:
Soft parity errors causing disruption on BES/FS8-18
Symptom:
If a parity error occurs in the encryption path, frames may be transmitted to the destination carrying
an incorrect payload and without being marked with an error. If a parity error occurs in the decryption
path, the frame data might not be decrypted successfully.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Fabric Services
Reported In Release:
FOS6.4.2
Service Request ID:
722589
Defect ID:
DEFECT000398718
Technical Severity:
High
Summary:
VEX port on FR4-18i requires Integrated Routing license on FOS v7.0.1 and FOS v7.0.1a; previous
releases did not require license.
Symptom:
Customer can no longer import device and run traffic without Integrated Routing license on FR4-18i
Vex port.
Risk of Fix:
Low
Feature:
Legacy FCR - 7500/FR4-18i
Probability:
High
Function:
Other
Reported In Release:
FOS7.0.1