- Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 1
53-1002751-01 ® 14 December 2012 Fabric OS Troubleshooting and Diagnostics Guide Supporting Fabric OS v7.1.0 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 2
to identify, products or services of their respective owners. Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 3
-01 Summary of changes First released edition. Date March 2008 Added support for Virtual Fabrics, fcPing, pathInfo, and additional troubleshooting tips. November 2008 Added support for checking physical connections, updated commands, removed obsolete information, and moved the FCIP and FICON - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 4
iv Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 5
Capturing command output 7 Building a case for your switch support provider 7 Basic information 7 Detailed problem information 8 Gathering additional information 9 Chapter 2 General Licenses 11 Time 11 Frame Viewer 12 Switch message logs 12 Fabric OS Troubleshooting and Diagnostics Guide - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 6
4 Switch boot 13 Rolling Reboot Detection 14 FC-FC routing connectivity 16 Generating and routing an ECHO 16 Superping 17 Route and statistical information 20 Performance issues 21 Connectivity Port initialization and FCP auto-discovery process 23 Link issues 25 Connection problems 25 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 7
Chapter 5 Chapter 6 Chapter 7 Chapter 8 Brocade configuration form 48 Firmware Download Errors Blade troubleshooting tips 51 Firmware download issues 52 Troubleshooting with the firmwareDownload command 54 Gathering additional information 55 USB error handling 55 Considerations for - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 8
Zone conflicts 75 Correcting a fabric merge problem quickly 76 Changing the default zone access 77 Editing zone configuration members 77 Reordering the zone member list 77 Checking for Fibre Channel connectivity problems 78 Checking for zoning problems 79 Gathering additional information 80 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 9
the host 113 Configuring the switch 114 Automatic trace dump transfers 115 Specifying a remote server 115 Enabling the automatic transfer of trace dumps 115 Setting up periodic checking of the remote server 115 Saving comprehensive diagnostic files to the server 116 Switch Type and Blade ID - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 10
x Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 11
performing firmware downloads, as well troubleshooting information. • Chapter 10, "Diagnostic Features," provides procedures for the use of the diagnostics commands for the chassis, ports, and other chassis equipment. Provides information on the system messages. • Appendix A, "Switch Type and Blade - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 12
switch • Brocade 8000 FCoE switch • Brocade VA-40FC • Brocade Encryption Switch • Brocade DCX • Brocade DCX-4S • Brocade DCX 8510-4 • Brocade DCX 8510-8 What's new in this document Updated for Brocade Fabric OS v7.1.0, including the following: • Updated system messages related to firmware downloads - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 13
to perform configuration tasks using the Fabric OS command line interface, but does not describe the commands in detail. For complete descriptions of all Fabric OS commands, including syntax, operand description, and sample output, refer to the Fabric OS Command Reference. Fabric OS Troubleshooting - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 14
to http://my.brocade.com and register at no cost for a user ID and password. For practical discussions about SAN design, implementation, and maintenance, you can obtain Building SANs with Brocade Fabric Switches through: http://www.amazon.com xiv Fabric OS Troubleshooting and Diagnostics Guide 53 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 15
number and corresponding bar code are provided on the serial number label, as illustrated below.: *FT00X0054E9* FT00X0054E9 The serial number label is located as follows: • Brocade 5424 - On the bottom of the switch module. Fabric OS Troubleshooting and Diagnostics Guide xv 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 16
your feedback to: [email protected] Provide the title and version number of the document and as much detail as possible about your comment, including the topic heading and page number and your suggestions for improvement. xvi Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 17
1 In this chapter •Troubleshooting overview 1 •Most common problem areas 2 •Questions for common symptoms 2 •Gathering information for your switch support provider 5 •Building a case for your switch support provider 7 Troubleshooting overview This book is a companion guide to be used in - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 18
1 Common troubleshooting problems and tools Problem area Investigate Tools Fabric Storage Devices Hosts Storage Management Applications • Missing devices • Switch LEDs • Marginal links (unstable connections) • Switch commands (for example, • Incorrect zoning configurations switchShow or - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 19
Licensing FCR LSAN tags FICON settings FTP or SCP server or USB availability Firmware version compatibility Unsupported features enabled Firmware versions on switch Fibre Channel over IP Administrator's Guide Fibre Channel over IP Administrator's Guide Chapter 2, "General" Fibre Channel over IP - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 20
ports Zoning E_Port QoS configuration mismatch Password recovery Chapter or Document Chapter 2, "General" Chapter 2, "General" Chapter 3, "Connectivity" Chapter 3, "Connectivity" Chapter 8, "ISL Trunking" Chapter 9, "Zoning" Fibre Channel over IP Administrator's Guide Chapter 2, "General" Chapter - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 21
name has been changed to a non-factory setting. If Virtual Fabrics is enabled, the supportSave command uses the default switch name for each logical fabric. 1. Connect to the switch and log in using an account with admin permissions. Fabric OS Troubleshooting and Diagnostics Guide 5 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 22
value 1. Connect to the switch and log in using an account with admin permissions. 2. Enter the supportSave command with the -t operand, and specify a value between 1 through 5. The following example increases the supportSave modules timeout to two times of the original timeout setting. switch:admin - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 23
Building a case for your switch support provider 1 3. Set the utility to capture output from the screen. Some utilities require this step to be performed prior to opening up a session. Check with your utility vendor for instructions. 4. Type the command or start the process to capture the required - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 24
on the switch? 7. Which CP blade was active? (Only applicable to Brocade DCX, DCX 8510 family, and DCX-4S enterprise-class platforms.) Detailed problem information Obtain as much of the following informational items as possible prior to contacting the SAN technical support vendor. Document the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 25
for your switch support provider to effectively and efficiently troubleshoot your issue. Refer to the chapter or document specified for the commands whose data you must capture: • Configurations, see Chapter 3, "Connectivity". • Firmwaredownload, see Chapter 5, "Firmware Download Errors". • Trunking - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 26
1 Building a case for your switch support provider 10 Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 27
to the Fabric OS Administrator's Guide to determine if the appropriate licenses are installed on the local switch and any connecting switches. Determining installed licenses 1. Connect to the switch and log in using an account with admin permissions. 2. Type the licenseShow command. A list of the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 28
was reported as successful. If the maximum number of switch users has been reached, the switch still performs correctly, in that it rejects the login of additional users, even if they enter the correct user name and password information. However, in this limited example, the Track Change feature - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 29
MQ errors are rare and difficult to troubleshoot; resolve them by working with the switch supplier. When encountering an MQ error, issue the supportSave command to capture debug information about the switch; then, forward the supportSave data to the switch supplier for further investigation. I2C bus - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 30
, the switch is put into a stable state so that a minimal supportSave can be collected and sent to your service support provider for reset case. • Software fault - Software Fault:Software Watchdog - Software Fault:ASSERT • Software recovery failure 14 Fabric OS Troubleshooting and Diagnostics Guide - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 31
Once the supportSave is completed, contact you service support provider to provide them with the data. Below is an example of the screen on a Brocade DCX. Fabos Version 7.1.0_main_bld23 switch login: admin Password: - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 32
change passwords for switch default accounts now. Use Control-C to exit or press 'Enter' key to proceed. FC-FC routing connectivity This section describes tools you can use to troubleshoot Fibre Channel routing connectivity and performance. Generating and routing an ECHO The FC-FC Routing Service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 33
21:00:00:20:37:25:ad:05: Command not supported: time: 1010 usec 5 frames sent, 0 frames received, 5 frames rejected, 0 frames timeout Round-trip min/avg/max = 0/0/0 usec of fcPing with a single destination (in this example, the destination is a device node WWN) switch:admin> fcping 20:00:00:00:c9:3f - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 34
FC-FC routing connectivity ATTENTION There are some devices that do not support command without any other options, superping covers all ISLs in the routes between source to destination, as shown in Figure 1. FIGURE 1 Superping and fcPing paths 18 Fabric OS Troubleshooting and Diagnostics Guide - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 35
-FC routing connectivity 2 In the following example, superping is invoked using the fcPing --allpaths command to destination domain 165. The following example displays each hop as (Domain1/Index1-> Domain2/Index2) format. To reach destination domain 165 from source domain 3 there are 2 unique end - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 36
remote fabrics, the destination switch must be identified by its domain ID. Identifying the switch by name or WWN is not accepted. Use the pathInfo command to display basic path information to a specific domain in command line mode: 20 Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 37
FC-FC routing connectivity 2 switch:admin> pathinfo 5 Hop In Port Domain ID (Name) Out Port BW Cost 0 2 1 (sw0) 6 the pathInfo command, refer to the Fabric OS Command Reference. 500 500 500 10000 500 - Performance issues Symptom General slow-down in FCR performance and scalability. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 38
2 FC-FC routing connectivity Symptom Host application times out. Probable cause and recommended action The FCR tends to take a long time, more than 5 seconds, to present and setup paths for the proxy devices. Certain hosts are able to do discovery much faster as a result they end up timing out. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 39
A Gigabit Ethernet switch port configured for an FCIP tunnel is called a VE port (virtual E-port). However, with a VEX_Port at the other end it does not propagate fabric services or routing topology information from one edge fabric to another. Fabric OS Troubleshooting and Diagnostics Guide 23 53 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 40
FCP auto-discovery process • VEX_Port-A virtual EX_Port. It connects a Fibre Channel router to an edge fabric. From the point of view of a switch in an edge fabric, a VEX_Port appears as a normal VE_Port. It follows the same Fibre Channel protocol as other VE_Ports. However, the router terminates - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 41
pinpoint the problem. One of the most common solutions is zoning. Verify that the host and target are in the same zone. For more information on zoning, refer to Chapter 9, "Zoning". Checking the physical connection • Check the cables running to and from the host and storage to the switch. This path - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 42
A device that is not logically connected to the switch is registered as a G_ or U_Port, if NPIV is not on the switch. 3. Enter the slotShow -m command to verify that all blades are ENABLED and not faulty, disabled or in some other non-available state. 4. Perform the appropriate actions based on how - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 43
number of successful logins and SCSI INQUIRY commands sent over this port and a list of the attached devices. 5. Check the port log to determine whether or not the device sent the FLOGI frame to the switch, and the switch probed the device. Fabric OS Troubleshooting and Diagnostics Guide 27 53 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 44
, speed_level command if the fields in step 5 do not appear. switch:admin> portcfgspeed Usage: portCfgSpeed PortNumber Speed_Level Speed_Level: 0 - Auto Negotiate 1 - 1Gbps 2 - 2Gbps 4 - 4Gbps 8 - 8Gbps ax - Auto Negotiate + enhanced retries 28 Fabric OS Troubleshooting and Diagnostics Guide 53 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 45
. The command entry AC indicates that the port has completed point-to-point initialization. switch:admin> portlogdumpport 4 time task event port cmd args 11:38:21.726 INTR pstate 4 AC 4. Skip over the loop initialization phase. Fabric OS Troubleshooting and Diagnostics Guide 29 53 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 46
link can involve inspecting the error counters described in "Troubleshooting a marginal link," or running diagnostics on a link, a port, or an end-to-end path. The portLoopbackTest command is used to verify the functional operation of a path on a switch. This test sends frames from a given port - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 47
side of the link are disabled. • The disc_c3 errors are discarded class 3 errors, which means that the switch is holding onto the frame longer than the hold time allows. One problem this could be related to is ISL oversubscription. Fabric OS Troubleshooting and Diagnostics Guide 31 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 48
the port blade or switch. • If the loopback test did not fail, the SFP was bad. 6. Replace the SFP on the marginal port. 7. Perform the following steps to rule out cabling issues: a. Insert a new cable in the suspected marginal port. b. Enter the portErrShow command to determine if a problem still - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 49
" (Trunk master) Pinpointing problems with device logins 1. Log in to the switch as admin. 2. Enter the switchShow command; then, check for state logins. 3. Enter the portCfgShow command to see if the port is configured correctly. Fabric OS Troubleshooting and Diagnostics Guide 33 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 50
G_PORT U_PORT SEGMENTED LOGIN LED 6. Enter the portLogDumpPort portid command where the port ID is the port number; then, view the device-to-switch communication. switch:admin> portlogdumpport 8 | more time task event port cmd args Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 51
, far-end terminal equipment, or transmission line. Diagnostics can be executed every day or on demand. Tests switch-to-switch ISL cabling and trunk group operations. The following procedures are for checking switch-specific components. Fabric OS Troubleshooting and Diagnostics Guide 35 53 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 52
to beacon a target port on the switch. For more information on using this command, refer to the Brocade Adapters Administrator's Guide. TABLE 7 Test Switch component tests Function portBeacon portLoopbackTest turboRamTest Sets port beaconing mode. Performs a functional test of port N to N path - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 53
as admin. 4. Enter the configShow -pattern "fabric.ops" command. 5. Compare the two switch configurations line by line and look for differences. Do this by comparing the two Telnet windows or by printing the configShow -pattern "fabric.ops" output. Also, verify that the fabric parameter settings - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 54
new switch during this process. 11. Repeat step 4 through step 10 if additional switches have conflicting domain IDs. Example of setting the domain ID switch_89:FID89:admin> switchdisable switch_89:FID89:admin> configure Configure... 38 Fabric OS Troubleshooting and Diagnostics Guide 53-1002751 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 55
into a fabric that has an older version of code, check the release notes to verify that any features on that switch are supported in the fabric with the newer code. When the Management Server (MS) Platform services are enabled on a switch running Fabric OS v7.0.0 and later and you try to merge this - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 56
Port mirroring Port mirroring With port mirroring, you can configure a switch port to mirror the traffic between a specific source and destination port. This is only supported between F_Ports. This is a useful way to troubleshoot a problem port without bringing down the host and destination links - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 57
from the same NPIV port or 10-bit addressing mode hit the same mirror connection, regardless of different AL_PAs, since the validation is done only for the first 16-bits of the SID/DID. • Port mirroring is not supported for the shared area ports of 48-port blades in the default switch. However, when - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 58
3 Brocade 8510-8 3 Brocade Encryption Switch 3 Brocade M5424 1 FC8-16/32 3 FS8-18 3 FX8-24 3 Configuring a port to be a mirror port 1. Connect to the switch and log in using an account with admin permissions. 2. Enter the portCfg mirrorport [slot number/] --enable command - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 59
following: switch:admin> portmirror --show Number of mirror connection(s) configured: 4 Mirror_Port SID DID State 18 0x070400 0x0718e2 Enabled 18 0x070400 0x0718e3 Enabled 18 0x070400 0x0718ef Enabled 18 0x070400 0x0718e0 Enabled Fabric OS Troubleshooting and Diagnostics Guide 43 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 60
3 Port mirroring 44 Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 61
command switch:admin> usbstorage -l firmwarekey\ 0B 2007 Aug 15 15:13 support\ 106MB 2007 Aug 24 05:36 support1034\ 105MB 2007 Aug 23 06:11 config\ 0B 2007 Aug 15 15:13 firmware\ 380MB 2007 Aug 15 15:13 FW_v6.0.0\ 380MB 2007 Aug 15 15:13 Available space on usbstorage 74% Fabric OS Troubleshooting - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 62
to Services FTP service. User (10.10.252.50:(none)): userFoo 331 Please specify the password. Password: 530 Login incorrect. Login failed. If your login to the FTP or SCP server has failed, verify the username and password are correct. 46 Fabric OS Troubleshooting and Diagnostics Guide - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 63
syntax. • The username and password are incorrect. The switch reboots during the configuration download. Probable cause and recommended action If you are issuing the command with the -vf option, the rebooting is normal. You can continue with the instructions. Otherwise issue the command again as - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 64
reference manuals for the Brocade DCX, and DCX-4S modular switches there is a guide for FC port setting tables. Print out Table 10 and use it to record configuration information for the various blades. TABLE 10 Brocade configuration and connection Brocade configuration settings Value IP address - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 65
) Brocade configuration settings Value Domain ID Switch name Ethernet IP address Ethernet subnet mask Total number of local devices (nsShow) Total number of devices in fabric (nsAllShow) Total number of switches in the fabric (fabricShow) Fabric OS Troubleshooting and Diagnostics Guide 49 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 66
4 Brocade configuration form 50 Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 67
for downgrading firmware 56 Blade troubleshooting tips This chapter refers to the following specific types of blades inserted into either the Brocade DCX, DCX 8510 family, and DCX-4S enterprise-class platforms: • FC blades or port blades contain only Fibre Channel ports: Brocade FC8-16/32 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 68
can enter the firmwareCommit command manually on the switch (or on the standby CP in director) to synchronize the partitions. After the firmware commit operation completes, reissue the firmwareDownload command to upgrade the system. 52 Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 69
or IP address, the user/password and the firmware path are valid. Cannot download the requested firmware. Probable cause and recommended action The firmware you are trying to download on the switch is incompatible. Check the firmware version against the switch type. If the firmware is incompatible - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 70
and firmwareShow commands to monitor its progress. If the problem persists, contact your switch support provider. Example of a firmwaredownload already in progress switch:admin> firmwaredownload Server Name or IP Address: 192.168.168.115 User Name: userFoo File Name: /users/home/userFoo/firmware/v7 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 71
blade is ENABLED. (error 3) Gathering additional information You should follow these best practices for firmware download before you start the procedure: • Keep all session logs. • Enter the supportSave or the supportShow command before and after entering the firmwareDownload command. • If a problem - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 72
Firmware (FOS, SAS, or any application) [FOS]: Server Name or IP Address: 10.1.2.3 User Name: userfoo File Name: /home/userfoo/v6.3.0 Network Protocol (1-auto-select, 2-FTP, 3-SCP) [1]: Password: Checking System Settings... Version compatibility check passed. 56 Fabric OS Troubleshooting - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 73
"configure" command to clear Location ID. Downgrade is not allowed because switch is in AG mode and D-Ports are configured. Please use "switchshow" to view the D-port list and use "portcfgdport --disable " to disable it before downgrading. Fabric OS Troubleshooting and Diagnostics Guide - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 74
FC10-6 blades are not supported on firmware v7.1.0, so the firmware download operation failed. Use the slotShow command to display which slots the Brocade FC10-6 blades occupy. Physically remove the blades from the chassis, or use the micro-switch to turn the blade off. Retry the firmware download - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 75
Probable cause and recommended action The firmware download operation was attempting to upgrade the SAS image while the blade was operational. Retry the firmwareDownload command again. Message Platform This system message pertains to switch features or fabric-wide settings that must be removed or - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 76
5 Considerations for downgrading firmware 60 Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 77
procedure to recover the password for the default accounts of user, admin, and factory. If you do not know the root password, you must contact your service support provider to recover admin passwords. Recovering passwords 1. Open a CLI connection (serial or Telnet) to the switch. 2. Log in as root - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 78
? Use passwd command to set other passwords. Use passwdDefault command to set all passwords to default. How to recover boot PROM password? Contact your switch service provider and provide the recovery string. How do I recover a user, admin, or factory password? Refer to "Passwords" on page - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 79
indicating an items? encrypted connection. Gathering additional information For security-related issues, use the following guidelines to gather additional data for your switch support provider. • Perform a supportSave -n command. • If not sure about the problem area, collect a supportSave -n from - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 80
-related issue then use supportSave -n to collect data from the Primary FCS switch and all affected switches. • If login-related, then also include the following information: - Does login problem appear on a Serial, CP IP, or Switch IP address connection? - Is it CP0 or CP1? - Is the CP in active or - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 81
or prevent users from deploying such a configuration, such a configuration is not supported. • ICL ports can only be in the base or default switch. If XISL is turned off, you can connect ICLs to other logical switches. • A default switch can be configured as a base switch in the Brocade 5100 and - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 82
do not support the use of VE_Ports to carry traffic for logical fabrics using XISLs. They can be used to carry FCR traffic through EX_Ports and VEX_Ports. You should make sure your configuration does not result in the use of VE_Ports in a base switch for logical fabric traffic. • Admin Domains are - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 83
command to reset the port to its default configuration. Symptom An EX_ or VEX_Port is disabled with reason Conflict: XISL capability domain. Probable cause and recommended action Use the configure command to set the value on the Allow XISL use to OFF on all logical switches of the connecting - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 84
7 Logical switch issues Logical switch issues CAUTION When a logical switch is created, all configuration for the logical switch is set to factory defaults. When a logical switch is deleted, all configuration for the logical switch is deleted permanently and is not recoverable. Symptom Symptom - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 85
blade is inserted, the switch configuration is checked based on the blade type. If the configuration does not match with the blade type, the blade is faulted. This is displayed as FAULTY(91) in the output of the slotShow command. Use the lsCfg -restore_slot_to_default command to correct the problem - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 86
-related issues, use the following guidelines to gather additional data for your switch support provider: • Perform the supportSave command. • If not sure about the problem area, perform the supportSave command on all chassis and logical switches in the fabric. • If you think it may be related to - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 87
100 and 101 connect to the switch 10:00:00:05:1e:34:02:45 The trunkDebug command displays the possible reason that two ports cannot be trunked. Possible reasons are: • The switch does not support trunking. • A trunking license is required. Fabric OS Troubleshooting and Diagnostics Guide 71 53 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 88
than the one you want it to. To correct this issue, connect additional ISLs to the switch with which you want to communicate. • The ports are not the same speed or they are not set to an invalid speed. Manually set port speeds to a speed supported on both sides of the trunk. • The ports are not - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 89
what might be causing the conflict. Verifying a TI zone problem Use the zone --show command to display information about TI zones. This command displays the following information for each zone: • zone name • E_Port members • N_Port members • configured status (the latest status, which may or may not - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 90
to display information about all zones, the TI zones appear in the defined zone configuration only and do not appear in the effective zone configuration. 1. Connect to the switch and log in as admin. 2. Enter the zone --show command. zone --show [name] where: name The name of the zone to be - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 91
zoning Command Function aliCreate aliDelete cfgCreate cfgShow cfgDisable Use to create a zone alias. Use to delete a zone alias. Use to create a zone configuration. Displays zoning configuration. Disables the active (effective) configuration Fabric OS Troubleshooting and Diagnostics Guide 75 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 92
have the incorrect zoning configuration; then, log in to the switches as admin. 2. Enter the switchDisable command on all problem switches. 3. Enter the cfgDisable command on each switch. 4. Enter the cfgClear command on each switch. 5. Enter the cfgSave command on each switch to commit the change - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 93
admin. 4. Enter the cfgShow command and print the output. 5. Compare the two fabric zone configurations line by line and look for an incompatible configuration. 6. Connect to one of the fabrics. 7. Run zone configure edit commands to edit the fabric zone configuration for the segmented switch (see - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 94
78 Zone conflicts Checking for Fibre Channel connectivity problems Enter the fcPing command (refer to the Fabric OS Command Reference for more information on this command), which checks the zoning configuration for the two ports specified by: • Generates an Extended Link Service (ELS) frame ECHO - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 95
. The defZone command sets the default zone access mode to No Access. switch:admin> defzone --show Default Zone Access Mode committed - No Access transaction - No Transaction See "Zone conflicts" on page 75 for additional information. Fabric OS Troubleshooting and Diagnostics Guide 79 53-1002751 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 96
Gathering additional information Collect the data from a supportSave -n command. Then collect the data from the cfgTransShow command. For the port having the problem, collect the data from the filterPortShow command. 80 Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 97
command to dump important diagnostic and status information to the session screen, where you can review it or capture its data. If you are using a Telnet client, you may have to set up the client to capture the data prior to opening the session Fabric OS Troubleshooting and Diagnostics Guide - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 98
captured using the supportSave command and downloaded by FTP off the switch, but when you are collecting information from specialized commands, such as supportShow, this information has to be captured using a Telnet client. To save a set of files that customer support technicians can use to further - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 99
, Slot 0 has passed the POST tests., main.c, line: 936 If you choose to bypass POST or after POST completes, various system services are started and the boot process displays additional console status and progress messages. Fabric OS Troubleshooting and Diagnostics Guide 83 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 100
view the rules, use the switchStatusPolicyShow command. Viewing the overall status of the switch 1. Connect to the switch and log in as admin. 2. Enter the switchStatusShow command: ecp:admin> switchstatusshow Switch Health Report Switch Name: brcdDCXbb IP address:192.168.234.63 SwitchState:DOWN - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 101
) associated with the logical switch and the switch role (default switch or base switch). Allows the switch to use extended interswitch links (XISL) in the base fabric to carry traffic to this logical switch. Values are ON or OFF. Fabric OS Troubleshooting and Diagnostics Guide 85 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 102
. Protocol support by GbE port. The details displayed for each switch differ on different switch models. For more information see the switchShow command in the Fabric OS Command Reference. To display the switch information, perform the following task. 1. Connect to the switch and log in as admin - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 103
connected to Brocade HBAs it is required that the firmware version on the HBA is v2.1.1 or later. 2. If you use the spinFab command to test F_Ports connected to Brocade HBAs it is required that the firmware version on the HBA is v2.1.1 or later. Fabric OS Troubleshooting and Diagnostics Guide - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 104
spinFab command monitors on both the ends simultaneously. Refer connected to the local and remote ports. • In case of loopback ports, change the loopback plug. Refer to "Marginal links" on page 30 for more information on changing the loopback plug. 88 Fabric OS Troubleshooting and Diagnostics Guide - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 105
port hardware statistics, including ALPA-based CRC monitor, End-to-End monitor, and filter-based performance monitor statistics. 1. Connect to the switch and log in as admin. 2. Enter the portStatsClear command. Enabling a port 1. Connect to the switch and log in using an account with - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 106
you to convert a Fibre Channel port into a diagnostic port for testing link traffic, electrical loopbacks, and optical loopbacks between a pair of switches, a pair of Access Gateways, and an Access Gateway and a switch. The ports must use 10G or 16G Brocade-branded SFPs. Support is also provided for - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 107
supported for ICLs. The fundamentals of D_Port testing are as follows: 1. The user configures the desired ports on both ends of the connection. 2. Once both sides are configured The user can also start (and restart) the test manually to verify Troubleshooting and Diagnostics Guide 91 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 108
request from remote port (a switch port if HBAs are used). Test start behavior Automatic User starts test (see "Automatic mode configuration" on page 98), but initial test suite is run automatically. Manual User starts test from switch side (using portdporttest - -start command) or from HBA side - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 109
5 illustrates ICLs between slots 5 and 8 in corresponding chassis. E represents E_Ports to be configured as D_Ports. The following equipment is supported, in any mix-or-match combination: • Chassis: Brocade DCX 8510-8, DCX 8510-4 Fabric OS Troubleshooting and Diagnostics Guide 93 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 110
an N_Port and an F_Port to be configured as D_Ports. (See note below.) There is no D_Port support for HBA connectivity to the Access Gateway. The following equipment is supported, in any mix-or-match combination: • Access Gateways: Brocade 6505, 6510 • Switches: Brocade DCX 8510-4, DCX 8510-8, 6505 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 111
to switch For configuration details see "Using D_Port with HBAs" on page 97. NOTE The following examples use command-line interface (CLI) commands. Refer also to the latest Brocade Host Connectivity Manager (HCM) and Brocade Network Advisor documentation to use those graphical user interface (GUI - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 112
10 Diagnostic Port (D_Port) 1. Disable Port 1 on Switch A, by using the portDisable [slot/]port command. switchA:admin> portdisable 1 2. Configure Port 1 on Switch A as a D_Port, by using portCfgDport - -enable [slot/]port. switchA:admin> portcfgdport --enable 1 3. Repeat steps 1 and 2 for the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 113
of the Brocade Command Line Utility (BCU) and Brocade Host Connectivity Manager (HCM) during or after testing. Once in D_Port mode, the adapter port does not participate in fabric operations, log in to a remote device, or run data traffic. Fabric OS Troubleshooting and Diagnostics Guide 97 53 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 114
Fabric OS Command Reference. For more details on adapter configuration, refer to the Brocade Fabric Adapters Administrator's Guide. Dynamic mode configuration This procedure enables a dynamic D_Port diagnostic session from the connected switch to an HBA. NOTE D_Port on HBAs is supported only on - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 115
considerations for D_Port configurations: • There is no support for D_Port connectivity between an HBA and an Access Gateway. • D_Port is supported only on Brocade 16-Gbps HBA (Brocade Fabric Adapter 1860) ports operating in HBA mode with a 16-Gbps SFP+ on Brocade 16-Gbps switches running Fabric OS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 116
the port. switch:admin> bcu port --disable 1/0 port disabled 3. Remove the connection to the switch and attempt to enable the D_Port. switch:admin> bcu diag --dportenable 1/0 ERROR: Timer expired - Retry if persists contact support Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 117
the command portCfgDport [slot/]port to enable or disable a D_Port configuration, with the following options. switch:admin> portcfgdport --help Usage: portcfgdport --enable portcfgdport --disable portcfgdport --help Specifying port ranges: port_range -- Specifies a set of - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 118
be taken as frame size. Default value is taken as 1024 switch:admin> portdporttest --show 26 D-Port Information: Port: 26 Remote WWNN: 10:00:00:05:33:13:2f:b5 Remote port: 42 Mode: Automatic Start time: Wed Feb 2 01:41:43 2011 End Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 119
all command to display the capabilities and test results of all the D_Ports in a switch. switch:admin> portdporttest --show all Port State SFP Capabilities Test Result 24 ONLINE E,O PASS 26 ONLINE E,O RESPONDER 33 OFFLINE --- RESPONDER Fabric OS Troubleshooting and Diagnostics Guide - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 120
Switch: No, Default Switch: No, Address Mode 0] Index Port Address Media Speed State Proto 24 24 010000 id N16 Online FC 26 26 010200 id N16 Online FC mismatch) 33 33 010300 id N8 Online FC -:NotApplicable, ??:INVALID 104 Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 121
ports and to help diagnose if your switch is experiencing port problems. Viewing the status of a port 1. Connect to the switch and log in as admin. 2. Enter the portShow [slot/] port command, specifying the number that corresponds to the port you are troubleshooting. In this example, the status of - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 122
statistics 1. Connect to the switch and log in as admin. 2. At the command line, enter the portStatsShow command. Port maximum Frames with bad end-of-frame Encoding error outside of frames Invalid ordered set Class 3 frames discarded due Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 123
switch 1. Connect to the switch and log in as admin. 2. Enter the portErrShow command. Refer to the Fabric OS Command Reference for additional portErrShow command information. switch:admin frames with good end-of-frame delimiters. Fabric OS Troubleshooting and Diagnostics Guide 107 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 124
Frames shorter than minimum Frames longer than maximum Frames with bad end-of-frame delimiters Encoding error outside of frames Class 3 frames 1. Connect to the switch and log in as admin. 2. Enter the fanShow command: switch:admin> fanshow 108 Fabric OS Troubleshooting and Diagnostics Guide 53- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 125
power supply status line. Checking temperature status 1. Connect to the switch and log in as admin. 2. Enter the tempShow command: switch:admin> tempshow Sensor State Centigrade Fahrenheit ID 1 Ok 28 82 2 Ok 16 60 Fabric OS Troubleshooting and Diagnostics Guide 109 53-1002751 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 126
from HEALTHY to DOWN. For details on error messages, refer to the Fabric OS Message Reference. Displaying the system message log, with no page breaks 1. Connect to the switch and log in as admin. 2. Enter the errDump command. 110 Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 127
lines is 32768 to 65536 for the. For all other switches, the number of lines range from 8192 to 16384. These ranges are for all ports on the switch, troubleshoot device connections. Viewing the port log 1. Connect to the switch and log in as admin. 2. Enter the portLogShow command: switch:admin - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 128
command displays the port log, showing a portion of the Fibre Channel payload and header (FC-PH). The header contains control and addressing information associated with the frame. The payload contains the information being transported by the frame and is determined by the higher-level service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 129
syslogd functionality. Fabric OS supports UNIX local7 facilities (the default facility level is 7). Configuring for syslogd involves configuring the host, enabling syslogd on the switch, and, optionally, setting the facility level. Configuring the host Fabric OS supports a subset of UNIX-style - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 130
switch Configuring the switch involves specifying syslogd hosts and, optionally, setting the facility level. You can also remove a host from the list of syslogd hosts. Specifying syslogd hosts 1. Connect to the switch and log in as admin. 2. Enter the syslogdIpAdd command and specify an IP address - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 131
10 3. Verify the IP address was deleted using the syslogdIpShow command. Automatic trace dump transfers You can set up a switch so that diagnostic information is transferred automatically to a remote server. If a problem occurs, you can then provide your customer support representative with the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 132
diagnostic files to the server 1. Connect to the switch and log in as admin. 2. Enter the supportSave -c command and respond to the prompts. switch:admin> supportsave -c This command will collect RASLOG, TRACE, supportShow, core file, FFDC data and other support information and then transfer them to - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 133
Type and Blade ID Appendix A The switchType is a displayed field listed when you run the switchShow command. When you are gathering information to give to your switch support provider, you may be asked the switch model. If you do not know the model, you can use this chart to convert the switchType - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 134
from the slotShow command. switch:admin> slotshow Slot Blade Type ID Model Name Status 1 SW BLADE 77 FC8-64 ENABLED 2 AP BLADE 75 FX8-24 ENABLED 3 AP BLADE 33 FA4-18 ENABLED 4 SW BLADE 39 FC8-64 ENABLED 5 CORE BLADE 52 CORE8 ENABLED 6 CP BLADE 50 CP8 ENABLED - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 135
bridge a Fibre Channel and Ethernet SAN. 24-FC port with 10 1-GbE and two 10-GbE ports Fibre Channel routing and FCIP blade 8 Gb 64-FC ports blade 16 Gb 48-FC ports blade 16 Gb 32-FC ports blade 8 Gb 32-FC ports blade 8 Gb 48-FC ports blade Fabric OS Troubleshooting and Diagnostics Guide 119 53 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 136
A Switch Type and Blade ID 120 Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 137
, is called a hex triplet. Fibre Channel uses hexadecimal notation in hex triplets to specify well-known addresses and port IDs. Example conversion of the hexadecimal triplet Ox616000 Notice the PID (610600 - bolded) in the nsShow output is in hexadecimal. switch:admin> nsshow { Type Pid COS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 138
170 Hex a1 a2 a3 a4 a5 a6 a7 a8 a9 aa Decimal 171 172 173 174 175 176 177 178 179 180 Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 139
245 246 247 248 249 250 Hex f1 f2 f3 f4 f5 f6 f7 f8 f9 fa Decimal 251 252 253 254 255 Hex fb fc fd fe ff Fabric OS Troubleshooting and Diagnostics Guide 123 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 140
B Hexadecimal Conversion 124 Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 141
, 63 not installed, 63 troubleshooting, 63 command output, 7 common problem areas, 2 symptoms, 2 configdownload fails, 3 configupload fails, 3 configuration download fails, 47 save to a host, 45 switch reboots during the download, 47, 48 upload fails, 45 connectivity no connectivity between host and - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 142
, reconcile, 37 segments, 3 fabric merge problem, 73 fabric segmentation configuration mismatch, 75 content mismatch, 75 default zone access, 77 fcPing, 78 Fibre Channel connectivity, 78 type mismatch, 75 zone configuration members, 77 zone conflict, 75 zoning problems, 79 fans, status of, 108 FCIP - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 143
connectivity between host and storage, 4 no connectivity between switches, 4 no light on LEDs, 4 NS, 26 NTP, 1 O output from a console, 6 P passwords, recovering forgotten, 61 pathInfo, 20 performance problems passwords, 61 Fabric OS Troubleshooting and Diagnostics Guide 127 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 144
36 TI zone problem, 73 time is not in-sync, 11 troubleshooting certificates, 63 corrupt certificate, 63 invalid certificate, 63 trunk bounces, 4 failed to form, 4 trunk goes offline and online (bounces), 72 U U_Port, 23 user forgot password, 4 user is unable to change switch settings, 5 using fcPing - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 145
Z zone configuration, 2 configuration mismatch, 5 content mismatch, 5 resolving conflicts, 75 troubleshooting, 75 type mismatch, 5 Fabric OS Troubleshooting and Diagnostics Guide 129 53-1002751-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Troubleshooting and Diagnostics Gui - Page 146
130 Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01
53-1002751-01
14 December 2012
®
Fabric OS
Troubleshooting and Diagnostics Guide
Supporting Fabric OS v7.1.0
®