Dell Brocade M5424 Brocade 7.1.0 Fabric Watch Administrator's Guide - Page 96
Environment monitoring setting guidelines, Environment class default settings, TABLE 24
View all Dell Brocade M5424 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 96 highlights
8 Environment monitoring Environment monitoring setting guidelines Use Environment Class default settings. Temperature settings are switch-dependent and there is no need to alter them. The default alarm configuration, sending alerts to the error log and SNMP, is sufficient. Environment class default settings Table 24 provides default Environment class settings for all switches. Check the appropriate hardware reference manual for differences in actual environmental requirements. NOTE Fabric Watch no longer supports fan monitoring. Event Manager (EM) now manages fan monitoring and the switch status is calculated based on the fan status reported by EM. TABLE 24 Area Environment class default settings Description Default threshold settings Temperature Monitors switch temperature in Celsius Unit: degrees C Time Base: none Brocade 200E Low: 0 High: 60 Buffer: 10 Brocade 300 Low: 0 High: 50 Buffer: 10 Brocade 5100 Low: 0 High: 63 Buffer: 10 Brocade 5300 Low: 0 High: 48 Buffer: 10 Brocade 7500 Low: 0 High: 63 Buffer: 10 Brocade 7600 Low: 0 High: 63 Buffer: 10 Brocade 7800 Low: 0 High: 58 Buffer: 10 Default alarm settings Threshold state Below: 3 Above: 3 Out-of-range Out-of-range (Same setting for all (Same setting for all devices) devices except Brocade DCX-4S) 76 53-1002752-01 Fabric Watch Administrator's Guide