Dell EqualLogic PS4210E EqualLogic Group Manager Administrator s Guide PS Seri - Page 156

Set the Data Center Bridging VLAN ID, Monitor Data Center Bridging Statistics and Configuration

Page 156 highlights

in the EqualLogic SAN. You can download the paper from: http://en.community.dell.com/techcenter/storage/w/wiki/ 4355.configuring-dcb-with-equallogic-sans.aspx Set the Data Center Bridging VLAN ID To set the DCB VLAN ID for the first time: 1. Click Group → Group Configuration. 2. Click the Advanced tab. 3. Enter the DCB VLAN ID in the VLAN ID field; it must be a value from 0 to 4095. This value must be the same as the VLAN ID configured in the switch for use by the iSCSI SAN. Values 0 and 1 are not recommended. NOTE: • The VLAN IDs on the switch must match the VLAN you specify on the group. The ports on the switch need to allow both the old VLAN (which usually implies a VLAN ID of 0 if none has been set) and the new VLAN ID or all VLANs (trunk mode) to enable the group to communicate with the switch. • All group members must be 10Gb arrays and be active. • You can also specify the DCB VLAN ID through the CLI using the grpparams dcb def-vlan-id command. See the Dell EqualLogic Group Manager CLI Reference Guide for more information. Change the Data Center Bridging VLAN ID If your group's DCB VLAN ID has been changed from the default value of 2, you must configure the group to use it. NOTE: • All group members must be active. • This procedure requires modifying the configuration of third-party products. See the documentation for your switches for detailed instructions on these tasks. 1. Set the switch ports used by group members to allow both the old and new VLAN IDs. 2. Bridge the old and new VLANs either by modifying switch settings or by creating an untagged access port for each VLAN and bridging the connections using the appropriate cable. 3. Set the VLAN ID in the group: a. Click Group → Group Configuration. b. Click the Advanced tab. c. In the Network Management panel, enter the new VLAN ID in the VLAN ID field. The value must be from 0 to 4095. 4. Reconfigure iSCSI initiators to use the new VLAN ID. 5. Unbridge the old and new VLANs. 6. (Optional) Modify switch ports so that the old VLAN ID is no longer allowed. Monitor Data Center Bridging Statistics and Configuration 1. Click Group. 2. Expand Members and then select the group member. 3. Click the Network tab. 4. In the IP Configuration panel, select a network interface. 5. The Switch Information section indicates the LLDP state of the switch connected to the interface. 6. In the Activities panel, click DCB Details to open the dialog box. NOTE: The DCB Details link appears dimmed if the member does not support DCB. 156 About Volumes

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324
  • 325
  • 326
  • 327
  • 328
  • 329
  • 330
  • 331
  • 332
  • 333
  • 334
  • 335
  • 336
  • 337
  • 338
  • 339
  • 340
  • 341
  • 342
  • 343
  • 344
  • 345
  • 346
  • 347
  • 348
  • 349
  • 350
  • 351
  • 352
  • 353
  • 354
  • 355

in the EqualLogic SAN. You can download the paper from:
4355.configuring-dcb-with-equallogic-sans.aspx
Set the Data Center Bridging VLAN ID
To set the DCB VLAN ID for the
first
time:
1.
Click
Group
Group
Configuration
.
2.
Click the
Advanced
tab.
3.
Enter the DCB VLAN ID in the
VLAN ID
field;
it must be a value from 0 to 4095. This value must be the same as the VLAN ID
configured
in the switch for use by the iSCSI SAN. Values 0 and 1 are not recommended.
NOTE:
The VLAN IDs on the switch must match the VLAN you specify on the group. The ports on the switch need to allow
both the old VLAN (which usually implies a VLAN ID of 0 if none has been set) and the new VLAN ID or all VLANs
(trunk mode) to enable the group to communicate with the switch.
All group members must be 10Gb arrays and be active.
You can also specify the DCB VLAN ID through the CLI using the grpparams dcb def-vlan-id command. See the
Dell
EqualLogic Group Manager CLI Reference Guide
for more information.
Change the Data Center Bridging VLAN ID
If your group’s DCB VLAN ID has been changed from the default value of 2, you must
configure
the group to use it.
NOTE:
All group members must be active.
This procedure requires modifying the
configuration
of third-party products. See the documentation for your switches for
detailed instructions on these tasks.
1.
Set the switch ports used by group members to allow both the old and new VLAN IDs.
2.
Bridge the old and new VLANs either by modifying switch settings or by creating an untagged access port for each VLAN and
bridging the connections using the appropriate cable.
3.
Set the VLAN ID in the group:
a.
Click
Group
Group
Configuration
.
b.
Click the
Advanced
tab.
c.
In the Network Management panel, enter the new VLAN ID in the VLAN ID
field.
The value must be from 0 to 4095.
4.
Reconfigure
iSCSI initiators to use the new VLAN ID.
5.
Unbridge the old and new VLANs.
6.
(Optional) Modify switch ports so that the old VLAN ID is no longer allowed.
Monitor Data Center Bridging Statistics and
Configuration
1.
Click
Group
.
2.
Expand
Members
and then select the group member.
3.
Click the
Network
tab.
4.
In the IP
Configuration
panel, select a network interface.
5.
The Switch Information section indicates the LLDP state of the switch connected to the interface.
6.
In the Activities panel, click
DCB Details
to open the dialog box.
NOTE: The DCB Details link appears dimmed if the member does not support DCB.
156